https://www.avient.com/sites/default/files/2022-07/ECCOH_ 5702 SEPAP - Riser Cables - Applications Snapshot.pdf
CABLE
MANUFACTURER
H I G H F L A M E R E T A R D A N T
S H E A T H F O R R I S E R C A B L E S
• Fire performance: CPR classification Dca s1 a1 d0 at a
thickness of 350µm
• Low shrinkage
• Water, UV and chemical resistance
• Low CoF
• Reduced cable weight by decreasing the jacket
thickness from 550µm to 350µm
• Provided required CPR classification at a reduced
thickness allowing installation in homes and
buildings in between walls and floors
• Increased cable lifetime due to improved
chemical and UV resistance
• Enabled fast cable processing
ECCOH™ 5702 SEPAP Formulation
KEY REQUIREMENTS
WHY AVIENT?
https://www.avient.com/products/engineered-polymer-formulations/eco-conscious-formulations/eccoh-low-smoke-and-fume-non-halogen-formulations
Cable Manufacturer
https://www.avient.com/sites/default/files/2024-10/ECCOH_ 5702 SEPAP Formulation - Shealth for Riser Cable - Application Snapshot.pdf
CABLE
MANUFACTURER
F L A M E - R E T A R D A N T S H E A T H
F O R R I S E R C A B L E S
• Fire performance: CPR classification Dca s1 a1 d0 at a
thickness of 350µm
• Low shrinkage
• Water, UV, and chemical resistance
• Low coefficient of friction (CoF)
• Reduced overall cable weight cable by
reducing the jacket thickness from 550µm to
350µm
• Increased the lifetime value of the cable by
providing superior chemical and UV resistance
• Provided low CoF on the inner layer, making
the solution suitable for use with micro ducts
as it’s easier to blow cables inside
ECCOH LSFOH 5702 SEPAP Formulation
KEY REQUIREMENTS
WHY AVIENT?
AVIENT SOLUTION
UV + CHEMICAL RESISTANCE
LEARN MORE
© 2024 Avient Corporation, All Rights Reserved
https://www.avient.com/products/engineered-polymer-formulations/sustainable-formulations/eccoh-low-smoke-and-fume-non-halogen-formulations
Cable Manufacturer
https://www.avient.com/resource-center?document_subtype=127&document_type=59&form_build_id=form-Ojq3VtEkRrXIsgZSyKvAgO_Z3JHuKtjJLR7xfOXoAI8&form_id=resource_filter_form&industry=0&op=FILTER RESULTS&product_family=81&product_name=0&product_subfamily=0&page=2
ECCOH 5161 - OFC Blowing Application in Railways
ECCOH™ 5970 - Thin FTTH Cables
ECCOH™ 5970 provide crush, chemical and UV resistance in thin FTTH cables
https://www.avient.com/sites/default/files/2021-06/eccoh-5161-loose-tube-telecommunications-cable-one-page-case-study.pdf
CABLE
MANUFACTURER
L O O S E T U B E T E L E C O M S
C A B L E
• Low shrinkage (< 1%)
• Consistent flame retardancy
• Suitable gel resistance
• Cold behaviour at - 40°C
• Reduce total cost ownership
• Improved processing compared to existing LSFOH
material, increasing speed up to 800 m/min
• Provided consultancy on processing parameters and
tooling
• Reduced cable thickness to 0.1mm & reduced
shrinkage
• Enabled customer to enter into new applications and
cable designs due to the versatility of the material
ECCOH™ 6151 LSFOH Formulations
KEY REQUIREMENTS
WHY AVIENT?
https://www.avient.com/products/engineered-polymer-formulations/eco-conscious-formulations/eccoh-low-smoke-and-fume-non-halogen-formulations
https://www.avient.com/news/easier-optical-fiber-installation-high-speed-connectivity-new-polyone-low-cof-formulation
With our new ECCOH 5702, workers can more easily guide it through conduit, even those with very complex designs and shapes, which reduces installation costs.”
For outdoor applications, ECCOH 5702 solutions can be UV stabilized, including formulations that pass the SEPAP accelerated aging test.
Caption: Optical fiber cable made with ECCOH 5702 solutions from PolyOne is easier to install in complex conduit and over long distances.
https://www.avient.com/sites/default/files/2020-11/eccoh-product-selection-guide-en.pdf
ECCOH™
LOW SMOKE AND FUME,
NON-HALOGEN
FORMULATIONS
PRODUCT SELECTION GUIDE
ECCOH™ Low Smoke and Fume, Non-Halogen Solutions
*Dry Silane abbreviated as DS
**Cross-linked using Sioplas method
5549 UV Teck-90 5700 5801 UV 5865 5982 UV 6010 6151 6638 UV XLS 8001
APPLICATION
Type Jacket Jacket Jacket Jacket Jacket Jacket Insulation
Tight buffer,
Micro-tube
Jacket Jacket
CABLE
Type LV, Data LV LV, Data, OFC LV, Data, OFC Data, OFC LV, OFC LV OFC Data, OFC LV
MARKETS
Type B & C, Industrial Industrial, Teck-90 B & C, Industrial
Industrial, Oil & Gas,
Shipboard
B & C B & C, Industrial Automotive B & C, Industrial B & C, Industrial B & C, Shipboard
Cross-linked No No No Yes No No Yes No No Yes
Cross-linking Method* N/A N/A N/A DS/E-beam N/A N/A DS/E-beam N/A N/A Sioplas
GENERAL PROPERTIES
Properties as Thermoset x x x
SG g/cm³ 1.59 1.54 1.60 1.50 1.57 1.52 1.38 1.46 1.48 1.48
MFI, 150°C/21.6 Kg g/10 min 2.8 5 6 3.5 4 5.9 4.4 6 3 6
Hardness Shore D 44 54 50 46 50 54 56 53 53 49
Tensile psi 1740 2610 1595 1800 1740 2320 3336 2466 2030 2030
Elongation % 160% 200% 136% 133% 180% 150% 145% 160% 175% 160%
LOI % 45% 36% 51% 39% 45% 41% 30% 33% 42% 33%
Low temp brittleness (LTB) °C -26.5°C -49°C -10.5°C -30°C -39°C -38.5°C -41°C -35.5°C -26 -40.5
Max.
Continuous Use Temp °C 90°C 90°C 105°C 90°C 125°C 90°C 90°C 105°C
SMOKE DENSITY (MAX)
Flaming Mode 45 104 312 163 312 118 98 60 101 121
Non-Flaming Mode 212 279 303 416 297 369 296 223 296 393
FEATURES
ESCR x
Flame Performance x x x x x
Heat Resistance x x x
High Char Forming x
Low Temperature
Performance x x
Mechanical Properties x x x
Oil Resistance x
UL Listed Halogen-Free x x x
FEATURES
Wire and Cable
• Highly flame retardant
• Very low toxicity and smoke density
• Many grades are cross-linkable
• Can be processed with color or additive
concentrate, and with UV stabilizer
Pipe and Fittings
• Highly flame retardant
• Very low toxicity and smoke density
• Suitable for extrusion, injection molding
ECCOH™
ECCOH™ non-halogenated formulations
re designed to be highly flame retardant
with extremely low toxicity and smoke
density.
https://www.avient.com/sites/default/files/2022-07/ECCOH_ 5806 - Gel filled Tight Buffer Aerial Cable - Application Snapshot.pdf
T I G H T B U F F E R I N G E L - F I L L E D
L O O S E T U B E F O R A E R I A L
C A B L E S
GLOBAL CABLE
MANUFACTURER
• Operating temperature from -40°C to 70°C
• High gel resistance
• Low shrinkage
• Stripability for easy installation
• Good flame retardancy
• Developed a formulation with good thermal behaviour
and low shrinkage
• Enabled a greater range of operating temperatures
giving the customer the flexibility of using the same
cable design in a range of different climates
• Provided superior gel resistance increasing life time of
the cable
• Utilized simulation service to optimize customer tooling
and extrusion output
ECCOH™ 5806 Formulation
KEY REQUIREMENTS
WHY AVIENT?
https://www.polyone.com/products/engineered-polymer-formulations/eco-conscious-formulations/eccoh-low-smoke-and-fume-non-halogen-formulations
Global cable manufacturer
https://www.avient.com/sites/default/files/2022-07/ECCOH_ 5981 BK UV - Aerial Drop Cable - Application Snapshot_0.pdf
CABLE
MANUFACTURER
A E R I A L D R O P C A B L E J A C K E T
• Operating temperature between -40°C to 70°C
• Fire performance: CPR classification Dca-, s1, d1, a1
• Low water absorption
• Clamp resistance
• Strong UV resistance & mechanical performance
• Improved thermal behaviour giving the customer
the flexibility to use the same cable design in a
wide range of climates
• Enabled superior mechanical performance and
water absorption over previous solutions
providing versatility and outdoor use
• Provided material in black color specifically used
in drop cables
ECCOH™ 5981 BK UV Formulations
KEY REQUIREMENTS
WHY AVIENT?
https://www.avient.com/products/engineered-polymer-formulations/eco-conscious-formulations/eccoh-low-smoke-and-fume-non-halogen-formulations
Cable manufacturer
https://www.avient.com/sites/default/files/2022-07/ECCOH_ 6151 Formulation - Semi-tigh Buffer Indoor Duplex Cable - Application Snapshot_0.pdf
EUROPEAN CABLE
MANUFACTURER
S E M I - T I G H T B U F F E R F O R
I N D O O R D U P L E X C A B L E S
• Low shrinkage for connectorization
• Easy to strip for efficient installation
• Good kink resistance
• Resistance to chemicals and filling compounds
• Provided an alternative solution, with improved
performance, compared to PA12 and PBT
materials on the market
• Reduced shrinkage and improved strippability for
easier installation
• Reduced smoke production, improving overall fire
performance
• Increased processing speeds, reducing overall
manufacturing cost
ECCOH™ 6151 Formulation
KEY REQUIREMENTS
WHY AVIENT?
https://www.polyone.com/products/engineered-polymer-formulations/eco-conscious-formulations/eccoh-low-smoke-and-fume-non-halogen-formulations
https://www.avient.com/sites/default/files/2023-10/Wire _ Cable Tri-fold Selection Guide_0.pdf
PRODUCT SELECTION GUIDE
WIRE & CABLE
SOLUTIONS
Specialty Engineered
Materials
High performance insulation, jacketing,
and cross-web formulations for the
wire and cable industry
Syncure™ XLPE Cross-linkable
Polyethylene Formulations
• Ambient curing
• Flame performance
• Resistant to heat, oil, creep,
& abrasion
• Low temperature properties
• Low capital investment
• High extrusion speeds
• DBDPE-free grades available
• UL/CSA bulletins
Maxxam™ FR Flame Retardant
Polyolefin Formulations
• FEP alternative
• Fire performance
• UL 444 & plenum yellow
card compliance
• Low dielectric
• High extrusion speeds
• Thin wall extrudability
Maxxam™ SY Foamable Flame
Retardant Formulations
• Low dielectric
• Uniform cell structure
• Crush & heat resistance
• Ease of chemical foaming
ECCOH™ Low Smoke and Fume
Non-Halogen Formulations
• Improved fire safety
• Low smoke, fume, non-halogen
(LSFOH) formulations
• Chemical resistance
ECCOH™ XL Cross-Linkable Solutions
• Non-halogen, low smoke, toxicity,
& corrosiveness
• Excellent mechanical & electrical
properties
• Easily processed
• Operating temperature of 90°C
• Moisture cure technology
Synprene™ Flame Retardant
Thermoplastic Elastomers
• Flexibility
• Flame performance
• Low temperature
brittleness (LTB) resistance
• Chemical resistance
• Easily colored
FireCon™ CPE Insulation Jacketing
Formulations
• Resistance to harsh environments
• Low temperature performance
• Flame performance
• High extrusion speeds
• Sunlight resistance
FEATURES SPECIFICATION
ECCOH™ XL 8148 Non-halogen, low smoke, toxicity, & corrosiveness EN50618
Syncure™ S100FH Horizontal flame UL 44
Syncure™ S100FH-XUV Horizontal flame, UV resistant UL 44
Syncure™ S100FH-UV Horizontal flame, FV-1 flame, UV resistant UL 44, UL 4703
Syncure™ S100FV VW-1 flame UL 44
Syncure™ S100FV-UV VW1, UV resistant UL 44
Syncure™ S112NA Non-flame retardant CSA 22.2
Syncure™ S120NA Non-flame retardant NSF 61
Syncure™ S200FH Horizontal flame, DBDPE-free UL 44
Syncure™ S200FV VW-1, DBDPE-free UL 44
INSULATION FOR POWER CABLE SYSTEMS
Low Voltage Power Cables
• Flame performance
• Resistance to heat, oil, creep, & abrasion
• Low temperature performance
• Low capital investment
• High extrusion speeds
INSULATION & CROSS-WEBS FOR DATA CABLE SYSTEMS
Category Cables
• FEP alternative
• Flame performance
• Low dielectric constant
• High extrusion speeds & thin wall capability
• Chemical resistance
• Low temperature performance
• Flexibility
FEATURES SPECIFICATION
Maxxam™ FR 0521-48 R1 Low smoke & fume, non-halogen UL 444
Maxxam™ FR 0587-21 R3 Halogenated to plenum performance UL 444
Optical Fiber Cables
• Resistance to harsh environments, chemicals, & sunlight
• Low temperature brittleness (LTB) resistance
• Low smoke & toxicity
• Flexibility
• High extrusion speeds
FEATURES SPECIFICATION
ECCOH™ 6649 UV Low DD Low smoke & fume, non-halogen Meets customer-specific flame requirements
Coaxial Cables
• Flexibility
• High extrusion speeds
• Low dielectric constant
• Uniform cell structure
• Crush & heat resistance
FEATURES SPECIFICATION
Maxxam™ SY 89-22-7 Foamable Meets customer-specific flame requirements
JACKETING FOR POWER & DATA CABLE SYSTEMS
Low & Medium Voltage Jacketing
• Resistance to harsh environments, chemicals, & UV degradation
• Low temperature brittleness (LTB) resistance
• Low smoke & toxicity
• Flexibility
• High extrusion speeds
• Easily colored
FEATURES SUBMARKETS & USES
FireCon™ CPE 30-33 RoHS Black Flame retardant, flexible Building & construction, industrial, nuclear
FireCon™ CPE 37-36 RoHS Black Flame retardant, flexible Building & construction, industrial, nuclear
FireCon™ CPE 30-20 RoHS Natural Flame retardant, flexible Building & construction, industrial, nuclear
ECCOH™ 5549 UV Low smoke & fume, non-halogen, flame retardant Building & construction, industrial
ECCOH™ 6649 UV Low DD Low smoke & fume, non-halogen, flame retardant Optical fiber, ducts
ECCOH™ 5981 UV Low smoke & fume, non-halogen, flame retardant Industrial, Teck 90 wire
Synprene™ RT5180 Flame retardant, LTB resistance Building & construction, industrial
Synprene™ RT5180UV Flame retardant, LTB resistance Building & construction, industrial
Synprene™ RT3870M Flame retardant, LTB resistance Building & construction, industrial
1.844.4AVIENT
www.avient.com
Copyright © 2023, Avient Corporation.