https://www.avient.com/sites/default/files/2020-08/mesa-pool-colorants-brochure_0.pdf
Processing conditions can cause material properties to shift from the values stated in the information.
https://www.avient.com/sites/default/files/resources/0514_02%2520PDI%2520ISO17025%2520Chemical_Extension%2520Cert2019.pdf
No. 0514.02) Revised 10/08/2019 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
POLYMER DIAGNOSTICS INC.
33587 Walker Road
Avon Lake, OH 44012
Ana De La Ree Phone: 440-930-3271
CHEMICAL
Valid To: December 31, 2019 Certificate Number: 0514.02
In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this
laboratory to perform the following rubber and plastics tests:
Test Description:
Test Method or Standard:
Analysis of Volatile Contaminants from Polymers
(Chromatography)
VDA 277
FTIR (Fourier Transform Infrared) Spectroscopy
ASTM E1252 (Except 7.6, 11.2, and 11.4)
Flammability
Horizontal Burn of Self-Supporting Plastics ASTM D635; UL 94; IEC 60695-11-10
Horizontal Burn of Materials Used in Occupant
Compartments of Motor Vehicles
ASTM D5132; FMVSS 302 (49 CFR 571.302)
Vertical Burn, 20 mm ASTM D3801; UL 94; IEC 60695-11-10
Vertical Burn, 125 mm ASTM D5048; UL 94; IEC 60695-11-20
Oxygen Index ASTM D2863
FT1 Flame Test UL1581, Clause 1060;
UL2556/CSA C22.2 No 2556, Clause 9.3
Cable Flame Test UL1581, Clause 1061
VW1 Flame Test UL1581, Clause 1080;
UL2556/CSA C22.2 No 2556, Clause 9.4
FT2/FH Flame Test UL1581, Clause 1100;
UL2556/CSA C22.2 No 2556, Clause 9.1
FV-1 Flame Test UL1581, Clause 1060;
UL2556/CSA C22.2 No 2556, Clause 9.5
Thin Material Burning Test UL-94
Glow Wire Test
IEC 60695 2-10, 2-11, 2-12, 2-13
RVCM in PVC
ASTM D4443
(A2LA Cert.
https://www.avient.com/sites/default/files/2020-11/syncure-xlpe-processing-guide.pdf
Precautions: the extruder should not be idle with the material in the barrel,
bleed constantly when possible.
Processing conditions can cause material properties to shift from the values stated in the information.
https://www.avient.com/sites/default/files/2023-05/Cesa Stat Product Selector Guide.pdf
Processing conditions can cause material properties to shift from the values stated in the information.
Cesa Stat Antistatic Additives - Standard Portfolio
POLYMER FAMILY MATERIAL PRODUCT NAME DOSAGE
Polyolefin PEATEC Cesa Stat PEATEC 1.0–4.0%
Polypropylene PPA0820051 Cesa Stat PPA0820051 1.0–4.0%
Polyamide ABAN698400 Cesa Stat 99027 5.0–15.0%
Polyester NBAN698440 Cesa Stat 3526 2.5–10.0%
Polycarbonate NCA0820011 Cesa Stat NCA0820011 5.0–8.0%
Styrenic SLAN698401 Cesa Stat 3301 3.0–7.5%
TPU RUA0820024 Cesa Stat RUA0820024 2.0–4.0%
Polyester FPA1660283 Hiformer™ liquid additives for polyolefins 0.10–0.50%
Cesa Stat Antistatic Additives can be used in combination with other Cesa masterbatches, and formulations can be customized for most applications.
https://www.avient.com/sites/default/files/2023-03/ColorMatrix Amosorb rPET Booster Product Bulletin.pdf
In order to satisfy the demand for a
circular economy, governments are legislating
increased use of recycled material in single use
packaging.
Processing conditions can cause material properties to shift from the values stated in the information.
https://www.avient.com/sites/default/files/2022-12/Renol Fiber Colorants Black Colorants for PET and PA Fibers Product Bulletin.pdf
Their high coverage potential
also makes them ideal for overshading/overdyeing
recycled materials or feedstock.
Processing conditions can cause material properties to shift from the values stated in the information.
https://www.avient.com/sites/default/files/2020-09/oncolor-hc-product-bulletin-1.pdf
KEY CHARACTERISTICS
• Polymer colorants formulated specifically for
healthcare product applications
• Meets and exceeds various material
performance requirements including
FDA 21 CFR, ISO 10993 and USP Class VI
• HC Plus colorants certified for bio-compatibility
• Available as pre-color, concentrate,
masterbatch or Smartbatch™ combined
colorant/additive solution
• Wide range of colors, striking special effects
and custom color matching
MARKETS AND APPLICATIONS
OnColor™ HC and HC Plus Colorants are an
excellent choice for medical devices and parts,
pharmaceutical or cosmetic packaging, and many
other healthcare related polymer applications.
Processing conditions can cause material properties to shift from the values stated in the information.
https://www.avient.com/sites/default/files/2021-11/0514-02-dec2021.pdf
No. 0514.02) Revised 09/21/2021 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
POLYMER DIAGNOSTICS INC.
33587 Walker Road
Avon Lake, OH 44012
Ana De La Ree Phone: 440-930-3271
CHEMICAL
Valid To: December 31, 2021 Certificate Number: 0514.02
In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this
laboratory to perform the following rubber and plastics tests:
Test Description:
Test Method or Standard:
Analysis of Volatile Contaminants from Polymers
(Chromatography)
VDA 277
FTIR (Fourier Transform Infrared) Spectroscopy
ASTM E1252 (Except 7.6, 11.2, and 11.4)
Flammability
Horizontal Burn of Self-Supporting Plastics ASTM D635; UL 94; IEC 60695-11-10
Horizontal Burn of Materials Used in Occupant
Compartments of Motor Vehicles
ASTM D5132; FMVSS 302 (49 CFR 571.302);
ISO 3785
Vertical Burn, 20 mm ASTM D3801; UL 94; IEC 60695-11-10
Vertical Burn, 125 mm ASTM D5048; UL 94; IEC 60695-11-20
Oxygen Index ASTM D2863
FT1 Flame Test UL1581, Clause 1060;
UL2556/CSA C22.2 No 2556, Clause 9.3
Cable Flame Test UL1581, Clause 1061
VW1 Flame Test UL1581, Clause 1080;
UL2556/CSA C22.2 No 2556, Clause 9.4
FT2/FH Flame Test UL1581, Clause 1100;
UL2556/CSA C22.2 No 2556, Clause 9.1
FV-1 Flame Test UL1581, Clause 1060;
UL2556/CSA C22.2 No 2556, Clause 9.5
Thin Material Burning Test UL-94
Glow Wire Test
IEC 60695 2-10, 2-11, 2-12, 2-13
RVCM in PVC
ASTM D4443
(A2LA Cert.
https://www.avient.com/sites/default/files/2024-07/Cesa and Hiformer Non-PFAS Process Aid Product Bulletin.pdf
Certain PFAS materials are subject to product bans,
leading to market exits by suppliers.
Processing conditions can cause material properties to shift from the values stated in the information.
https://www.avient.com/sites/default/files/2023-06/Supplier Code of Conduct FV.pdf
water, sources of energy,
raw materials) in an economical way.
Section 307 of the Tariff Act of 1930 (19 U.S.C. §
1307), ILO Forced Labor Convention (No. 29) and the
Abolition of Forced Labour Convention (No. 105), in
the mining, production, manufacture or supply of any
goods (which includes both raw materials and
manufactured goods) or services for Avient, nor, in
connection with its supply to Avient, will Supplier
procure merchandise from any sub-supplier that was
mined, produced, or manufactured, in whole or in
part, using forced labor.
Inform Avient of financial, economic, supply changes
(including origin or conflict status of 3TG metals),
government regulations or other materials
conditions that could affect ongoing operations or
operating decisions, or if the company has been
debarred as a government contractor