https://www.avient.com/sites/default/files/2022-03/Trilliant HC Conductive Pipette Tips Application Snapshot.pdf
LEADING BIOTECH
MANUFACTURER
C O N D U C T I V E P I P E T T E T I P S
• Accuracy of liquid measurements
• Hydrophobic properties to minimize fluid retention
• Concentric dimensional stability and warp resistance
• High flow properties for multi-cavity molds
• Offered consistent electrical conductivity to
achieve repeatable part performance and
minimize failures from inconsistent
conductivity
• Provided high flow grade with easy
processing to improve efficiency and cost
effectiveness
• Achieved high stiffness and warp
resistance, minimizing the rejection rate
Trilliant™ HC Conductive Formulation
KEY REQUIREMENTS
WHY AVIENT?
https://www.avient.com/products/engineered-polymer-formulations/chemical-corrosion-resistant-formulations/trilliant-hc-healthcare-thermoplastics
https://www.avient.com/sites/default/files/2021-08/trilliant-surgical-stapler-housing-case-study-one-pager.pdf
HEALTHCARE
DEVICE OEM
S U R G I C A L S T A P L E R
H O U S I N G
• Easy-to-mold, durable, and good aesthetics
• Excellent disinfection performance and good chemical
resistance
• Compatible with high- and low-temperature sterilization
• Delivered durable and aesthetically pleasing
specialty polymer with the added benefit of
processing flexibility without retooling
• Passed physical, chemical and disinfection
tests in different testing conditions which
proved good tensile strength and chemical
resistance
• Achieved consistent molding shape and
properties
Trilliant™ HC Thermoplastics
KEY REQUIREMENTS
WHY AVIENT?
https://www.avient.com/products/engineered-polymer-formulations/chemical-corrosion-resistant-formulations/trilliant-hc-healthcare-thermoplastics
https://www.avient.com/sites/default/files/2020-10/case-study-one-pager-trilliant-xr-xray-glasses.pdf
MEDICAL EQUIPMENT
MANUFACTURER
S U R G I C A L X - R A Y G L A S S E S
• Replace lead while providing uniform shielding
performance
• Radiation shielding up to 140KeV
• Improve glasses design
• Compliance with Radiation Protection Regulation: Adult
eye exposure must be below 20 mSv per calendar year
• Conducted extensive testing to ensure comparable and
uniform shielding performance
• Improved geometric flexibility
• Lowered shielding component costs 30-50% by
eliminating machining and assembly steps (associated
with lead)
• Reduced weight of the glasses and enabled a more
ergonomic design
• Eliminated disposal concerns associated with lead
Trilliant™ XR Lead Replacement
Thermoplastics
KEY REQUIREMENTS
WHY AVIENT?
https://www.avient.com/products/engineered-polymer-formulations/conductive-signal-radiation-shielding-formulations/trilliant
Medical equipment manufacturer
https://www.avient.com/sites/default/files/2021-12/Chemically Resistant Materials Whitepaper.pdf
The
Trilliant HC8900 and Edgetek ET8900 series are
polymer blends based on linear aliphatic PK.
Second to the Trilliant series, the FR copolyester
demonstrated good ESCR performance, but
struggled against more aggressive disinfectants
(e.g., Virex® TB).
Resistance ratings for Trilliant HC8900 series and competing materials against common healthcare disinfectants
https://www.avient.com/sites/default/files/2022-03/Trilliant HC Electrically Conductive Formulations for Pipette Tips Application Bulletin-CN3.24-1.pdf
Trilliant HC 导电方案专为移液枪头定制,旨在打造能
将导电性、机械性和加工性融为一体的独特组合。
Trilliant 方案可定制化,以实现高流动性和易加工性,
有利于高效成型和部件间性能一致。
Trilliant HC 导电热塑性塑料可根据您的独有挑战进行定制。
https://www.avient.com/news/avient’s-newest-trilliant-hc-materials-stand-disinfectants-better-alternative-fr-polymers
Homepage
//
News Center
//
Avient’s Newest Trilliant™ HC Materials Stand Up to Disinfectants Better Than Alternative FR Polymers
Trilliant™ HC8910 and HC8920 healthcare grades were developed in response to today’s intense disinfecting protocols.
Trilliant™ HC8910 and HC8920 series of materials are made without BPA and available in standard or custom colors.
https://www.avient.com/sites/default/files/2020-10/auto-injector-application-study.pdf
Requirements:
Self lubricating for reduced
friction and improved durability
Trilliant™ LubriOne™ Internally
Lubricated Formulations
10.
Requirements:
Heat transfer
Trilliant™ Therma-Tech™
Thermally Conductive
Formulations
14.
Requirements:
Thermal conductivity for warming
of medicants
Trilliant™ Therma-Tech™
Thermally Conductive
Formulations
Heating system
13
Heat Exchanger
14
Technology Enabled
Design
Connected medical devices are
transforming the way care is
delivered by making it simpler, easier,
more collaborative, and more data
driven.
https://www.avient.com/sites/default/files/2021-06/chemical-resistance-technical-bulletin.pdf
$$$
$$
$
Improved Chemical Resistance
Trilliant ™
Material Compatibility with Various Disinfectants
8.5% Bleach 3% Peroxide Cidex® OPA CaviCide™ Virex™ Tb
$$$
$$
$
Improved Chemical Resistance
Trilliant ™
Material Compatibility with Various Disinfectants
8.5% Bleach 3% Peroxide Cidex® OPA CaviCide™ Virex™ Tb
www.avient.com
Copyright © 2021, Avient Corporation.
https://www.avient.com/industries/healthcare/medical-devices-equipment/imaging-technology
Trilliant™ HC Healthcare Thermoplastics
Trilliant™ XR Lead Replacement Thermoplastics
Trilliant™ Surgical X-Ray Glasses
https://www.avient.com/sites/default/files/2024-09/Chemical Resistance Technical Bulletin %281%29.pdf
$$$
$$
$
Improved Chemical Resistance
Trilliant ™
Material Compatibility with Various Disinfectants
8.5% Bleach 3% Peroxide Cidex® OPA CaviCide™ Virex™ Tb
$$$
$$
$
Improved Chemical Resistance
Trilliant ™
Material Compatibility with Various Disinfectants
8.5% Bleach 3% Peroxide Cidex® OPA CaviCide™ Virex™ Tb
www.avient.com
Copyright © 2021, Avient Corporation.