https://www.avient.com/sites/default/files/resources/Clinton%2520IATF%252016949-2016%2520exp%25207-2-2021.pdf
ABS Quality Evaluations This is to certify that the Quality Management System of: PolyOne Corporation PolyOne 1260 Carden Farm Drive Clinton, TN 37716 U.S.A.
IATF 16949:2016 The Quality Management System is applicable to: Certificate No: 38223 Effective Date: 03 July 2018 Expiration Date: 02 July 2021 Issue Date: 03 July 2018 IATF No: 0313794 Alex Weisselberg, President DESIGN AND COMPOUNDING OF THERMOPLASTIC PRODUCTS (WITH ADDITIONAL FACILITIES LISTED ON ATTACHED ANNEX) Certificate Of Conformance has been assessed by ABS Quality Evaluations, Inc. and found to be in conformance with the requirements set forth by: Page 2 of 2 ABS Quality Evaluations PolyOne Corporation IATF 16949:2016 Certificate Of Conformance ANNEX At Below Facilities: Validity of this certificate may be confirmed at www.abs-qe.com/cert_validation.
https://www.avient.com/sites/default/files/2024-12/2024 Avient Executive Bios_John Midea.pdf
JOHN MIDEA Senior Vice President, Global Operations and Process Improvement John Midea is Senior Vice President, Global Operations and Process Improvement at Avient Corporation, an innovator of materials solutions that help customers succeed while enabling a sustainable world.
He spent 12 years at Valspar Corporation with increasing roles of responsibility, including Vice President, where he was accountable for the North American segment of its liquid, powder, electrocoat and after market specialty chemical businesses.
Avient Corporation • 33587 Walker Road • Avon Lake, Ohio 44012 • 440.930.1000 • www.avient.com
https://www.avient.com/sites/default/files/2024-12/2024 Avient Executive Bios_Giuseppe Di Salvo.pdf
GIUSEPPE DI SALVO Vice President, Treasurer and Investor Relations Giuseppe “Joe” Di Salvo is Vice President, Treasurer and Investor Relations at Avient Corporation, an innovator of materials solutions that help customers succeed while enabling a sustainable world.
He was then promoted to vice President, Corporate Controller.
Avient Corporation • 33587 Walker Road • Avon Lake, Ohio 44012 • 440.930.1000 • www.avient.com
https://www.avient.com/sites/default/files/2022-08/Avient Candidates Data Privacy Notice Final - Spanish.pdf
Avient Corporation Aviso de privacidad del Candidato Agradecemos su interés en trabajar para Avient.
Para obtener mas información acerca de como Avient trata sus datos personales para estos servicios y sitios web externos, le pedimos que visite la Declaración de Privacidad de Avient Corporation, disponible en https://www.avient.com/company/policies-and-governance/avient-corporation-privacy-statement).
HH. participen en la tramitación de su solicitud; • Avient Corporation como director de esta plataforma de reclutamiento; • Proveedores de servicios técnicos que traten datos para Avient Corporation Tratamiento de datos a nivel de todo el grupo: como grupo con operaciones globales, las empresas del grupo Avient trabajan en estrecha colaboración.
https://www.avient.com/sites/default/files/resources/PolyOne%2520IR%2520Presentation%2520%25E2%2580%2593%2520Recast%2520Financial%2520Information%2520for%2520Discontinued%2520Operations.pdf
These costs are included in Corporate and eliminations.
Certain corporate costs previously allocated to DSS will be retained by PolyOne and have been recast as costs in continuing operations.
The costs are now shown in Corporate and eliminations as follows: 2013 ($14.0M), 2014 ($14.7M), 2015 ($13.0M) and 2016 ($11.6M).
https://www.avient.com/sites/default/files/2025-02/ColorMatrix LQ-Extrusion Pipe-Case study snapshot.pdf
U-PVC PIPE & FITTING PRODUCER P I P E & F I T T I N G • Meet the diverse coefficient of friction (CoF) requirements across various film structures and compositions for a wide range of applications • Improve the speed of slip blooming and ensure consistent slip performance post-film production • Preserve excellent optical and mechanical properties • Compliance with food regulations for end packaging in food sealant applications • Improved the customer’s workplace environment by installing a new tote liquid supply system • Enhanced color consistency and reduced production wastage from pigment speck and streak issues • Complied with strict regulatory controls for potable pipe requirements ColorMatrix Liquid Color Concentrates KEY REQUIREMENT WHY AVIENT AVIENT SOLUTION PRODUCTIVITY + COMPLIANCE Avient Corporation 1 • Meet the diverse coefficient of friction (CoF) requirements across various film structures and compositions for a wide range of applications • Improve the speed of slip blooming and ensure consistent slip performance post-film production • Preserve excellent optical and mechanical properties • Compliance with food regulations for end packaging in food sealant applications KEY REQUIREMENT • Standard colorant to apply for internal color matching in PVC sheet applications • Phthalate free plasticizer class as hazardous healthy control requirement • Good thermal stability and compatibility in PVC resin of color index choices • Compliance with Heavy metal free and RoHS regulation KEY REQUIREMENT• Support the mass production capacity of white pipe extrusion • Reduces particulates from TiO2 bulk pigment use in the workplace • Ensure excellent pigment dispersion to meet mechanical pipe properties over an extensive useful life • Compliance with NSF and UL regulations for end application requirements in the building and construction industry LIQUID COLOR CONCENTRATES AND DOSING | AVIENTLEARN MORE KEY REQUIREMENTS Copyright © 2025, Avient Corporation.
https://www.avient.com/sites/default/files/2024-12/Avient Norwalk A2LA ISO17025-17.pdf
No. 0962.01) 09/05/2023 Page 1 of 1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 AVIENT CORPORATION 80 North West Street Norwalk, OH 44857 Craig Polta Phone: 419 660 4278 MECHANICAL Valid To: September 30, 2025 Certificate Number: 0962.01 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following tests on plastics: Test Method(s) Test Name ASTM D256; ISO 180 Notched Izod ISO 179 (1eA) Determination of Charpy Impact ASTM D523 Gloss ASTM D618 (Method A) Conditioning of Test Specimens ASTM D792 (Method A) Specific Gravity ASTM D1238 (Method B) Melt Flow Rate ASTM D3012 Thermal Oxidative Stability ASTM D3641 Injection Molding Test Specimens FMVSS 302 Flammability ASTM E1331; SAE J1545 Spectrophotometric Color Difference SAE J1885 (Rev.
Accredited Laboratory A2LA has accredited AVIENT CORPORATION Norwalk, OH for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories.
https://www.avient.com/sites/default/files/2025-07/ISO IEC 17025 Chemical Avon Lake.pdf
No. 0514.02) 12/11/2023 Page 1 of 1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 AVIENT CORPORATION – ANALYTICAL SOLUTIONS 33587 Walker Road Avon Lake, OH 44012 Stephanie Mims Phone: 440-930-3499 CHEMICAL Valid To: September 30, 2025 Certificate Number: 0514.02 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following rubber and plastics tests: Test Description: Test Method or Standard: FTIR (Fourier Transform Infrared) Spectroscopy ASTM E1252 (Except 7.6, 11.2, and 11.4) Flammability Horizontal Burn of Self-Supporting Plastics ASTM D635; UL 94; IEC 60695-11-10 Horizontal Burn of Materials Used in Occupant Compartments of Motor Vehicles ASTM D5132; FMVSS 302 (49 CFR 571.302); ISO 3785 Vertical Burn, 20 mm ASTM D3801; UL 94; IEC 60695-11-10 Vertical Burn, 125 mm ASTM D5048; UL 94; IEC 60695-11-20 Thin Material Burning Test UL-94 Glow Wire Test IEC 60695 2-10, 2-11, 2-12, 2-13 Thermal Analysis DSC (Differential Scanning Calorimetry) ASTM D3418, E794, E1356 TGA (Thermogravimetric Analysis) ASTM E1131 TMA (Linear Thermal Expansion of Solid Materials by Thermomechanical Analysis) ASTM E831; ISO 11359-2 Karl Fischer Moisture Content ASTM D6869 For the tests to which this accreditation applies, please refer to the laboratory’s Chemical Scope of Accreditation.
Accredited Laboratory A2LA has accredited AVIENT CORPORATION – ANALYTICAL SOLUTIONS Avon Lake, OH for technical competence in the field of Chemical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories.
https://www.avient.com/sites/default/files/2025-07/ISO IEC 17025 Mechanical Avon Lake.pdf
No. 0514.01) 12/11/2023 Page 1 of 1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 AVIENT CORPORATION – ANALYTICAL SOLUTIONS 33587 Walker Road Avon Lake, OH 44012 Stephanie Mims Phone: 440 930 3499 MECHANICAL Valid To: September 30, 2025 Certificate Number: 0514.01 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following rubber and plastics tests: Test Description Test Method or Standard Brittleness Temperature (Impact) ASTM D746; ISO 812 Charpy Impact ISO 179-1 Color Determination by Spectrophotometer ASTM D2244, E1331; ISO 7724 Conditioning of Plastics for Testing ASTM D618; ISO 291 Deflection Temperature Under Flexural Load ASTM D648; ISO 75-1, -2 Durometer Hardness (Shore A and D) ASTM D2240; ISO 7619-1 Flexural Properties ASTM D790; ISO 178 Flow Rate (Extrusion Plastometer) ASTM D1238 (Procedures A and B); ISO 1133 Impact Resistance (Izod) ASTM D256; ISO 180 Instrumented Impact ASTM D3763; ISO 6603-2 Specific Gravity/Density ASTM D792 (Method A); ISO 1183-1 Specular Gloss ASTM D523; ISO 2813 Tackiness of Interior Materials BO 061-01 Tear Resistance ASTM D624, D1004; ISO 34 Tensile Properties ASTM D412 (Method A), D638, D882; ISO 37, 527-1, -2, -3, -4, -5 Xenon-Arc Exposure Testing ASTM D2565, G155; SAE J1885 (Withdrawn January 2008), J1960 (Withdrawn January 2008), J2412, J2527; BO-116-01 For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation.
Accredited Laboratory A2LA has accredited AVIENT CORPORATION – ANALYTICAL SOLUTIONS Avon Lake, OH for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories.
https://www.avient.com/sites/default/files/2022-08/Avient Candidates Data Privacy Notice Final - English.pdf
Avient Corporation Candidates Privacy Notice We welcome your interest in working for Avient.
For more information about how Avient processes your personal information for these services and third-party websites, please visit the Avient Corporation Privacy Statement, available at https://www.avient.com/company/policies-and-governance/avient-corporation-privacy-statement.
Contact Us If you have any questions or want to exercise any of your rights, you can contact us at: The Corporate Privacy Officer Avient Corporation 33587 Walker Road Avon Lake, Ohio 44012 Email: PRIVACY.OFFICER@AVIENT.COM Phone: 1-800-901-2078 You may also send us your privacy questions or requests through our online form.