https://www.avient.com/knowledge-base/article/overmolding-guide?pname[]=91
Avient is a recognized leader in the overmoldingof thermoplastic elastomers (TPEs), offering excellent adhesion to substrates like polypropylene, polyethylene, PC, ABS, acetal, and nylon.
https://www.avient.com/knowledge-base/article/overmolding-guide?rtype[]=1164
Avient is a recognized leader in the overmoldingof thermoplastic elastomers (TPEs), offering excellent adhesion to substrates like polypropylene, polyethylene, PC, ABS, acetal, and nylon.
https://www.avient.com/knowledge-base/article/overmolding-guide
Avient is a recognized leader in the overmoldingof thermoplastic elastomers (TPEs), offering excellent adhesion to substrates like polypropylene, polyethylene, PC, ABS, acetal, and nylon.
https://www.avient.com/company/sustainability/sustainability-report/products/markets/automotive-case-study
Paint replacement technologies, including Artisan™ ABS portfolio and Molded-In Color Metallic
https://www.avient.com/news/archives?page=33
New Artisan™ ABS Thermoplastic Solution from Avient Features Metallic Effect for Electronics Brands
https://www.avient.com/sites/default/files/2022-08/Environmental Stress Cracking Resistance _ESCR_ Design Guide %281%29.pdf
Wall Thickness (mm) C o o li n g T im e ( S e c ) 40 35 30 25 20 15 10 5 0 0 1 2 3 4 ABS PC Nylon 6/6 FIGURE 1 - Wall thickness vs. cooling time of various plastics FIGURE 2 - Designing for wall thickness changes FIGURE 3 - Internal and external radius guidelines FIGURE 4 - Coring for tight radius design ESCR Design Guide 2 CONTOUR Where possible, contouring the products’ exterior form, as shown in Figure 5, can help to eliminate pooling of fluids.
https://www.avient.com/sites/default/files/2023-12/Polystrand Thermoplastic Composite Panel Application _ Install Guide.pdf
GL AS S/ EP OX Y TA B M AT ER IA L N O T AB BOTTOM PANEL LEG LENGTH BREAK STRENGTH Hammerhead with 5 lb/ft3 (80 kg/m3) Core Density 2 in 51 mm 420 lbs 191 kg Hammerhead with 7 lb/ft3 (115 kg/m3) Core Density 2 in 51 mm 370 lbs 168 kg Hammerhead with 8 lb/ft3 (135 kg/m3) Core Density 2 in 51 mm 332 lbs 151 kg Marine Plywood 2 in 51 mm 984 lbs 446 kg Glass/Polyester with Balsa Core 2 in 51 mm 1298 lbs 589 kg Hammerhead with 5 lb/ft3 (80 kg/m3) Core Density - ITW Plexus MA420 Adhesive NA 501 lbs 227 kg Hammerhead with 7 lb/ft3 (115 kg/m3) Core Density - ITW Plexus MA420 Adhesive NA 839 lbs 381 kg Hammerhead with 8 lb/ft3 (135 kg/m3) Core Density - ITW Plexus MA420 Adhesive NA 1156 lbs 524 kg Hammerhead with 8 lb/ft3 (135 kg/m3) Core Density - Crestomer 1152PA Adhesive NA 1530 lbs 694 kg Hammerhead with 8 lb/in3 (135 kg/m3) Core Density - Crestomer M1-30 Adhesive NA 1471 lbs 667 kg Mixed Conditions ADHESIVE DESCRIPTION ADHESIVE GRADE MANUFACTURER AVERAGE BOND STRENGTH STANDARD DEVIATION FAILURE MODE BEST ADHESION 2k Urethane 75421 LORD 2281 psi 15.73 MPa 184 psi 1.27 MPa Substrate Cohesive 2k Acrylic SA1-705 GRY1 ACRALOCK 2211 psi 15.24 MPa 78 psi 0.54 MPa Substrate 2k Acrylic Plexus MA420 ITW 2171 psi 14.97 MPa 262 psi 1.81 MPa Substrate 2k Acrylic SA10-05 Blk1 ACRALOCK 2102 psi 14.49 MPa 138 psi 0.95 MPa Substrate 2k Urethane 75451 LORD 2047 psi 14.11 MPa 68 psi 0.47 MPa Cohesive 2k Acrylic SA1-705 GRY 1:1 ACRALOCK 1966 psi 13.56 MPa 68 psi 0.47 MPa Substrate 2k Acrylic Scotch-Weld 8010 3M 1907 psi 13.15 MPa 61 psi 0.42 MPa Adhesive Cyanoacrylate Gorilla Glue Gorilla Glue 1885 psi 13.00 MPa 432 psi 2.98 MPa Cohesive 2k Acrylic Crestabond PP-04 Scott Bader 1873 psi 12.91 MPa 281 psi 1.94 MPa Substrate 2k Acrylic SA10-05 Blk 10:1 ACRALOCK 1779 psi 12.27 MPa 127 psi 0.88 MPa Cohesive 2k Urethane 75422 LORD 1716 psi 11.83 MPa 190 psi 1.31 MPa Cohesive Adhesive 2k Urethane 75452 LORD 1535 psi 10.58 MPa 98 psi 0.68 MPa Adhesive 2k Methacrylate PolyFuse Icon Containment 1610 psi 11.10 MPa 98 psi 0.68 MPa Adhesive INTERMEDIATE ADHESION 2k Acrylic FA10-05 Blk C010817 ACRALOCK 724 psi 4.99 MPa 58 psi 0.40 MPa Cohesive 2k Acrylic FA10-05 Blk1 ACRALOCK 722 psi 4.98 MPa 44 psi 0.30 MPa Cohesive 2k Epoxy Loctite Epoxy Instant Mix Loctite 508 psi 3.50 MPa 81 psi 0.56 MPa Adhesive 2k Epoxy Gorilla Epoxy Gorilla Glue 341 psi 2.35 MPa 198 psi 1.37 MPa Adhesive NOT RECOMMENDED 2k Epoxy Loctite Epoxy Marine Loctite 0 0 No bond ADHESIVE SELECTION Brand names of the adhesives are owned by the respective manufacturers.
https://www.avient.com/sites/default/files/2023-10/2023 Hammerhead Application _ Install Guide.pdf
GL AS S/ EP OX Y TA B M AT ER IA L N O T AB BOTTOM PANEL LEG LENGTH BREAK STRENGTH Hammerhead with 5 lb/ft3 (80 kg/m3) Core Density 2 in 51 mm 420 lbs 191 kg Hammerhead with 7 lb/ft3 (115 kg/m3) Core Density 2 in 51 mm 370 lbs 168 kg Hammerhead with 8 lb/ft3 (135 kg/m3) Core Density 2 in 51 mm 332 lbs 151 kg Marine Plywood 2 in 51 mm 984 lbs 446 kg Glass/Polyester with Balsa Core 2 in 51 mm 1298 lbs 589 kg Hammerhead with 5 lb/ft3 (80 kg/m3) Core Density - ITW Plexus MA420 Adhesive NA 501 lbs 227 kg Hammerhead with 7 lb/ft3 (115 kg/m3) Core Density - ITW Plexus MA420 Adhesive NA 839 lbs 381 kg Hammerhead with 8 lb/ft3 (135 kg/m3) Core Density - ITW Plexus MA420 Adhesive NA 1156 lbs 524 kg Hammerhead with 8 lb/ft3 (135 kg/m3) Core Density - Crestomer 1152PA Adhesive NA 1530 lbs 694 kg Hammerhead with 8 lb/in3 (135 kg/m3) Core Density - Crestomer M1-30 Adhesive NA 1471 lbs 667 kg Mixed Conditions ADHESIVE DESCRIPTION ADHESIVE GRADE MANUFACTURER AVERAGE BOND STRENGTH STANDARD DEVIATION FAILURE MODE BEST ADHESION 2k Urethane 75421 Lord 2281 psi 15.73 MPa 184 psi 1.27 MPa Substrate Cohesive 2k Acrylic SA1-705 GRY1 AccraLock 2211 psi 15.24 MPa 78 psi 0.54 MPa Substrate 2k Acrylic Plexus MA420 ITW 2171 psi 14.97 MPa 262 psi 1.81 MPa Substrate 2k Acrylic SA10-05 Blk1 AccraLock 2102 psi 14.49 MPa 138 psi 0.95 MPa Substrate 2k Urethane 75451 Lord 2047 psi 14.11 MPa 68 psi 0.47 MPa Cohesive 2k Acrylic SA1-705 GRY 1:2 AccraLock 1966 psi 13.56 MPa 68 psi 0.47 MPa Substrate 2k Acrylic Scotchweld 8010 3M 1907 psi 13.15 MPa 61 psi 0.42 MPa Adhesive Cyanoacrylate Gorilla Glue Gorilla Glue 1885 psi 13.00 MPa 432 psi 2.98 MPa Cohesive 2k Acrylic Crestabond PP-04 Scott Bader 1873 psi 12.91 MPa 281 psi 1.94 MPa Substrate 2k Acrylic SA10-05 Blk 10:2 AccraLock 1779 psi 12.27 MPa 127 psi 0.88 MPa Cohesive 2k Urethane 75422 Lord 1716 psi 11.83 MPa 190 psi 1.31 MPa Cohesive Adhesive 2k Urethane 75452 Lord 1535 psi 10.58 MPa 98 psi 0.68 MPa Adhesive 2k Methacrylate Polyfuse Icon Containment 1610 psi 11.10 MPa 98 psi 0.68 MPa Adhesive INTERMEDIATE ADHESION 2k Acrylic FA10-05 Blk C010817 AccraLock 724 psi 4.99 MPa 58 psi 0.40 MPa Cohesive 2k Acrylic FA10-05 Blk1 AccraLock 722 psi 4.98 MPa 44 psi 0.30 MPa Cohesive 2k Epoxy Loctite Epoxy Instant Mix Loctite 508 psi 3.50 MPa 81 psi 0.56 MPa Adhesive 2k Epoxy Gorilla Glue Epoxy Gorilla Glue 341 psi 2.35 MPa 198 psi 1.37 MPa Adhesive NOT RECOMMENDED 2k Epoxy Loctite Epoxy Marine Loctite 0 0 No bond ADHESIVE SELECTION Brands identified are owned by the manufacturers of the adhesive products. 1 surface sanded with 220 grit scuff prep 2 surface primed with 459T FASTENER TYPE BENEFITS CONSIDERATIONS Through-Bolting Best mechanical locking system Need back side access to panel Screw-In Anchor Highest pullout strength Requires pilot hole Cup Washer Spreads compressive load Requires relief hole; For substructure and hard point attachment Wide Grip (Bulb-Style) Rivet Ease of use—no installation torque limitations For lower load attachments Sheet Metal or Wood Screw Readily available, low cost Penetrate both skins for improved pullout Shoulder Washer Limits compressive load Requires relief hole; For substructure and hard point attachment For more information on installation, adhesives, and fasteners for specific applications, please contact Avient.
https://www.avient.com/knowledge-base/article/new-aesthetix
Snow white and the seven speckles - discrete, white/off-white/pearlescent speckles for injection molded PE, PP, ABS, and SAN
https://www.avient.com/sites/default/files/2020-10/2020-gravi-tech-design-guide-.pdf
CHAPTER 3 | PART DESIGN GUIDELINES Wall Thickness (mm) C o o li n g T im e ( S e c ) 40 35 30 25 20 15 10 5 0 0 1 2 3 4 ABS PC Nylon 6/6 Figure 2 - Designing for Wall Thickness Changes Bad Better Recommended Recommended Poor High Stress Ideal Figure 3 - Internal and External Radius Guidelines .5W Min Inside Rad + W Poor High Volume FIGURE 1 - Wall thickness vs. cooling time of various plastics FIGURE 2 - Designing for wall thickness changes FIGURE 3 - Internal and external radius guidelines Design Guide 9 RIB DESIGN GUIDELINES The minimum distance ribs should be spaced is three times the nominal wall thickness (3W).
Solvent Solvents soften surfaces of plastic (plastic must be soluble)—best for amorphous or low crystalline plastics, such as ABS, acrylic, cellulosic, PC, PS, PPO, and vinyls.
Venting Guidelines by Resin • PC: .001"–.002" depth & .250" width • PC/PSU: .002"–.003" depth & .250" width • PES: .003"–.004" depth & .250" width • PEI: .001"–.003" depth & .250" width • PP: .001"–.002" depth & .250" width • ABS: .0015"–.0025" depth & .250" width • PEEK: .002"–.004" depth & .250" width FIGURE 40 - Venting Guidelines Vent Groove Vent Land Vent FIGURE 44 - Venting guidelines FIGURE 43 - Venting areas 20 Gravi-Tech CHAPTER 5 | PROCESS OPTIMIZATION Process optimization ensures a quality process and minimizes cycle time.