https://www.avient.com/sites/default/files/2024-03/Terms and Conditions of Sale for Sweden.pdf
Seller warrants good and clear title
in goods subject to the sale (“Product”) and that the Product con-
forms at the time of shipment to a Certificate of Analysis, a Cer-
tificate of Compliance, or a Product Specification Sheet, if any
such document exists, and other specifications signed by Seller
(“Specifications”).
Buyer acknowledges that information in
Seller’s marketing materials, technical data sheets and other de-
scriptive publications distributed or published on its websites
beskrivs ovan ska alla utestående fordringar från Säljaren
omedelbart förfalla till betalning avseende de Produkter som
levererats till Köparen och inte återtagits av Säljaren.
10.
Buyer acknowledges that Seller has furnished
to Buyer Safety Data Sheets, which include warnings together
with safety and health information concerning the Product
and/or the containers for such Product.
https://www.avient.com/sites/default/files/2020-10/luxury-closures-gravi-tech-design-guide-2.0-application-specific.pdf
A larger processing window
will account for the lot to lot changes between
materials, without having to make process
changes.3
Setting the Beginning Variables
• Injection Pressure = Maximum of machine
- Should not be pressure limited
• Injection Velocity = Maximum of machine
- This is for the injection velocity curve
starting point
- If flashing is an issue start slower and
then increase
• Injection Cut-Off Time = 15 seconds
- This is only a limiting factor, needs to
be above 10 seconds for velocity graph
• Hold Pressure = 0
- Need to get 95% full part with a hold
pressure of 0
• Hold Time = 10-15 seconds
- Need to ensure gate is frozen
• Screw Speed = 90% of Maximum
- Unless shear sensitive material, if shear
sensitive, set RPMs to optimum
• Cooling Time = 10–15 seconds
• Shot Size = 50% of calculated part volume
• Decompression = .25"
• Transfer Position = High enough to ensure
a cushion
- Cushion size does not matter but there
must be a cushion to keep a constant
pressure on the melt during hold time
- Typically 0.25" is sufficient
• Back Pressure = 800-1000 plastic pressure
- 100–150 hydraulic pressure
- Unless specified by material data sheet
Determining Shot Size
The shot size should be determined by
calculating the combined volume of the parts
and the runner system.
If
the material is shear-sensitive, consult the
material data sheet or processing guide for
instructions to set recovery time
• The cooling time should only be 1–2 seconds
longer than the screw recovery time, unless
dictated by dimensional stability or part
thickness
Minimize Clamp Pressure
This step is done to reduce the amount of energy
used by the machine
Shot Size = 1.00 + .10 =
1.10, Transfer Position = .50 + .10 = .60
Set Safeties
This step is to ensure the machine will alarm
and alert nearby employees if the machine
malfunctions, or if a part gets stuck
https://www.avient.com/sites/default/files/2023-10/Wire _ Cable Tri-fold Selection Guide_0.pdf
PRODUCT SELECTION GUIDE
WIRE & CABLE
SOLUTIONS
Specialty Engineered
Materials
High performance insulation, jacketing,
and cross-web formulations for the
wire and cable industry
Syncure™ XLPE Cross-linkable
Polyethylene Formulations
• Ambient curing
• Resistant to heat, oil, creep,
& abrasion
• Low temperature properties
• Low capital investment
• DBDPE-free grades available
• UL/CSA bulletins
Maxxam™ FR Flame Retardant
Polyolefin Formulations
• FEP alternative
• Fire performance
• UL 444 & plenum yellow
card compliance
• Low dielectric
• High extrusion speeds
• Thin wall extrudability
Maxxam™ SY Foamable Flame
Retardant Formulations
• Low dielectric
• Uniform cell structure
• Crush & heat resistance
• Ease of chemical foaming
ECCOH™ Low Smoke and Fume
Non-Halogen Formulations
• Improved fire safety
• Low smoke, fume, non-halogen
(LSFOH) formulations
ECCOH™ XL Cross-Linkable Solutions
• Non-halogen, low smoke, toxicity,
& corrosiveness
• Excellent mechanical & electrical
properties
• Easily processed
• Operating temperature of 90°C
• Moisture cure technology
Synprene™ Flame Retardant
Thermoplastic Elastomers
• Low temperature
brittleness (LTB) resistance
• Easily colored
FireCon™ CPE Insulation Jacketing
Formulations
• Resistance to harsh environments
• Sunlight resistance
ECCOH™ XL 8148 Non-halogen, low smoke, toxicity, & corrosiveness EN50618
Syncure™ S100FH Horizontal flame UL 44
Syncure™ S100FH-XUV Horizontal flame, UV resistant UL 44
Syncure™ S100FH-UV Horizontal flame, FV-1 flame, UV resistant UL 44, UL 4703
Syncure™ S100FV VW-1 flame UL 44
Syncure™ S100FV-UV VW1, UV resistant UL 44
Syncure™ S112NA Non-flame retardant CSA 22.2
Syncure™ S120NA Non-flame retardant NSF 61
Syncure™ S200FH Horizontal flame, DBDPE-free UL 44
Syncure™ S200FV VW-1, DBDPE-free UL 44
INSULATION FOR POWER CABLE SYSTEMS
Low Voltage Power Cables
• Resistance to heat, oil, creep, & abrasion
• Low capital investment
INSULATION & CROSS-WEBS FOR DATA CABLE SYSTEMS
Category Cables
• FEP alternative
• Low dielectric constant
• High extrusion speeds & thin wall capability
• Flexibility
Maxxam™ FR 0521-48 R1 Low smoke & fume, non-halogen UL 444
Maxxam™ FR 0587-21 R3 Halogenated to plenum performance UL 444
Optical Fiber Cables
• Resistance to harsh environments, chemicals, & sunlight
• Low temperature brittleness (LTB) resistance
• Low smoke & toxicity
ECCOH™ 6649 UV Low DD Low smoke & fume, non-halogen Meets customer-specific
flame requirements
Coaxial Cables
• Flexibility
• Low dielectric constant
• Uniform cell structure
• Crush & heat resistance
Maxxam™ SY 89-22-7 Foamable Meets customer-specific
flame requirements
JACKETING FOR POWER & DATA CABLE SYSTEMS
Low & Medium Voltage Jacketing
• Resistance to harsh environments, chemicals, & UV degradation
• Low temperature brittleness (LTB) resistance
• Low smoke & toxicity
• Flexibility
• High extrusion speeds
• Easily colored
FEATURES SUBMARKETS & USES
FireCon™ CPE 30-33 RoHS Black Flame retardant, flexible Building & construction, industrial,
FireCon™ CPE 37-36 RoHS Black Flame retardant, flexible Building & construction, industrial,
FireCon™ CPE 30-20 RoHS Natural Flame retardant, flexible Building & construction, industrial,
ECCOH™ 5549 UV Low smoke & fume, non-halogen,
flame retardant Building & construction, industrial
ECCOH™ 6649 UV Low DD Low smoke & fume, non-halogen,
flame retardant Optical fiber, ducts
ECCOH™ 5981 UV Low smoke & fume, non-halogen,
flame retardant Industrial, Teck 90 wire
Synprene™ RT5180 Flame retardant, LTB resistance Building & construction, industrial
Synprene™ RT5180UV Flame retardant, LTB resistance Building & construction, industrial
Synprene™ RT3870M Flame retardant, LTB resistance Building & construction, industrial
1.844.4AVIENT
www.avient.com
Copyright © 2023, Avient Corporation.
https://www.avient.com/sites/default/files/resources/PDI_Healthcare_Brochure_2011_0.pdf
This
information sheet shall NOT operate as permission, recommendation, or inducement to practice any patented invention without permission of the patent owner.
33587 Walker Road
Avon Lake, Ohio 44012
United States
+1 800 438 2335
+1 440 930 1644 fax
Polymer Diagnostics Inc. is a contract laboratory with accreditation to ISO/IEC 17025 by the American
Association for Laboratory Accreditation (A2LA) for both chemical and mechanical capacities.
At PDI, our goals are to help clients:
• Solve the toughest technical problems
• Grow their business
• Commercialize products quickly
Core Competencies
We offer unmatched expertise in material, process, and end product polymer
testing, including:
• Support studies for device qualifi cation
• Material analysis and identifi cation
• Suggestions on process improvement
• Advanced failure analysis
• Litigation support
The PDI Difference
We provide solutions—not just raw data
We help you determine the root cause of failure and recommend real-world
solutions and better routes to successful commercialization.
This
information sheet shall NOT operate as permission, recommendation, or inducement to practice any patented invention without permission of the patent owner.
33587 Walker Road
Avon Lake, Ohio 44012
United States
+1 800 438 2335
+1 440 930 1644 fax
Polymer Diagnostics Inc. is a contract laboratory with accreditation to ISO/IEC 17025 by the American
Association for Laboratory Accreditation (A2LA) for both chemical and mechanical capacities.