https://www.avient.com/news/polyone-features-polymer-solutions-and-services-designed-specifically-mexico-and-central-america-plastimagen
Reinforced Polyolefins for Automotive: Maxxam™ LO low odor talc-filled polypropylenes and Maxxam™ XST thermoplastic olefins are the latest additions to a complete line of specially formulated polyolefins.
Maxxam™ LO materials help OEMs meet vehicle interior air quality (VIAQ) standards in underhood HVAC applications because it enables reduced VOC emissions and consistently achieves odor testing results of 3.0 per VDA 270.
In addition, Maxxam™ XST materials offer an exceptional balance of stiffness and impact performance for automotive interior design, even in cold temperatures.
https://www.avient.com/sites/default/files/2020-12/case-study-one-pager-maxxam-fr-fridge-base.pdf
GLOBAL FRIDGE MANUFACTURER R E F R I G E R A T O R B A S E • Provide 5VA flame retardant rating • Utilize existing molds • Keep the same mechanical and physical properties as current material • Dimensional stability – limit shrinkage of final part • High strength – bearing the weight of the whole fridge • Maintain or reduce weight • Expedited development time, providing solutions ready for testing within a week • Enabled first time approval through close customer collaboration • Provided excellent in person support to both customer and moulder throughout trials • Gave technical advice on how to adjust processing parameters, enabling the use of existing molds with the new material Maxxam™ FR Flame Retardant Formulations KEY REQUIREMENTS WHY AVIENT?
All Rights Reserved. https://www.avient.com/products/engineered-polymer-formulations/flame-retardant-formulations/maxxam-fr-flame-retardant-polyolefin-formulations Global Fridge manufacturer
https://www.avient.com/news/archives?page=45
Improved Vehicle Interior Air Quality Made Possible with New PolyOne Maxxam™ LO
TROY, Mich. – October 9, 2018 – At the SPE TPO Automotive Engineered Polyolefins Conference today, PolyOne unveiled Maxxam™ LO, a low odor
https://www.avient.com/news/archives?page=24
Caption: Avient adds Maxxam™ REC recycled polyolefins and Maxxam™ BIO bio-based polyolefin grades to its broad portfolio of sustainable specialty
https://www.avient.com/sites/default/files/2025-02/Maxxam_ Polyolefin Formulations- Coaxial Signal Cable Jacket - case study snapshot.pdf
AUTO DATA CABLE MANUFACTURER C O A X I A L S I G N A L C A B L E J A C K E T • Provide good chemical resistance like that of machine oil • Pass 3,000 hours aging test of finish goods • Have low dielectric property - characteristic impedance of transmission line: 100Ω, capacitance in water: around 102.8pf/m • Provided excellent performance with low dielectric constant to make the jacket layer of signal cables have low capacitance loss • Offered a solution by combining physical and chemical foaming products in the foaming layer to reduce the dielectric constant further • Maintained exceptional mechanical properties under high temperatures Maxxam Polyolefin Formulations KEY REQUIREMENTS WHY AVIENT?
All Rights Reserved https://www.avient.com/products/engineered-polymer-formulations/general-engineered-formulations/maxxam-polyolefin-formulations Slide 1: Auto data Cable manufacturer
https://www.avient.com/sites/default/files/2023-10/Wire _ Cable Tri-fold Selection Guide_0.pdf
PRODUCT SELECTION GUIDE WIRE & CABLE SOLUTIONS Specialty Engineered Materials High performance insulation, jacketing, and cross-web formulations for the wire and cable industry Syncure™ XLPE Cross-linkable Polyethylene Formulations • Ambient curing • Flame performance • Resistant to heat, oil, creep, & abrasion • Low temperature properties • Low capital investment • High extrusion speeds • DBDPE-free grades available • UL/CSA bulletins Maxxam™ FR Flame Retardant Polyolefin Formulations • FEP alternative • Fire performance • UL 444 & plenum yellow card compliance • Low dielectric • High extrusion speeds • Thin wall extrudability Maxxam™ SY Foamable Flame Retardant Formulations • Low dielectric • Uniform cell structure • Crush & heat resistance • Ease of chemical foaming ECCOH™ Low Smoke and Fume Non-Halogen Formulations • Improved fire safety • Low smoke, fume, non-halogen (LSFOH) formulations • Chemical resistance ECCOH™ XL Cross-Linkable Solutions • Non-halogen, low smoke, toxicity, & corrosiveness • Excellent mechanical & electrical properties • Easily processed • Operating temperature of 90°C • Moisture cure technology Synprene™ Flame Retardant Thermoplastic Elastomers • Flexibility • Flame performance • Low temperature brittleness (LTB) resistance • Chemical resistance • Easily colored FireCon™ CPE Insulation Jacketing Formulations • Resistance to harsh environments • Low temperature performance • Flame performance • High extrusion speeds • Sunlight resistance FEATURES SPECIFICATION ECCOH™ XL 8148 Non-halogen, low smoke, toxicity, & corrosiveness EN50618 Syncure™ S100FH Horizontal flame UL 44 Syncure™ S100FH-XUV Horizontal flame, UV resistant UL 44 Syncure™ S100FH-UV Horizontal flame, FV-1 flame, UV resistant UL 44, UL 4703 Syncure™ S100FV VW-1 flame UL 44 Syncure™ S100FV-UV VW1, UV resistant UL 44 Syncure™ S112NA Non-flame retardant CSA 22.2 Syncure™ S120NA Non-flame retardant NSF 61 Syncure™ S200FH Horizontal flame, DBDPE-free UL 44 Syncure™ S200FV VW-1, DBDPE-free UL 44 INSULATION FOR POWER CABLE SYSTEMS Low Voltage Power Cables • Flame performance • Resistance to heat, oil, creep, & abrasion • Low temperature performance • Low capital investment • High extrusion speeds INSULATION & CROSS-WEBS FOR DATA CABLE SYSTEMS Category Cables • FEP alternative • Flame performance • Low dielectric constant • High extrusion speeds & thin wall capability • Chemical resistance • Low temperature performance • Flexibility FEATURES SPECIFICATION Maxxam™ FR 0521-48 R1 Low smoke & fume, non-halogen UL 444 Maxxam™ FR 0587-21 R3 Halogenated to plenum performance UL 444 Optical Fiber Cables • Resistance to harsh environments, chemicals, & sunlight • Low temperature brittleness (LTB) resistance • Low smoke & toxicity • Flexibility • High extrusion speeds FEATURES SPECIFICATION ECCOH™ 6649 UV Low DD Low smoke & fume, non-halogen Meets customer-specific flame requirements Coaxial Cables • Flexibility • High extrusion speeds • Low dielectric constant • Uniform cell structure • Crush & heat resistance FEATURES SPECIFICATION Maxxam™ SY 89-22-7 Foamable Meets customer-specific flame requirements JACKETING FOR POWER & DATA CABLE SYSTEMS Low & Medium Voltage Jacketing • Resistance to harsh environments, chemicals, & UV degradation • Low temperature brittleness (LTB) resistance • Low smoke & toxicity • Flexibility • High extrusion speeds • Easily colored FEATURES SUBMARKETS & USES FireCon™ CPE 30-33 RoHS Black Flame retardant, flexible Building & construction, industrial, nuclear FireCon™ CPE 37-36 RoHS Black Flame retardant, flexible Building & construction, industrial, nuclear FireCon™ CPE 30-20 RoHS Natural Flame retardant, flexible Building & construction, industrial, nuclear ECCOH™ 5549 UV Low smoke & fume, non-halogen, flame retardant Building & construction, industrial ECCOH™ 6649 UV Low DD Low smoke & fume, non-halogen, flame retardant Optical fiber, ducts ECCOH™ 5981 UV Low smoke & fume, non-halogen, flame retardant Industrial, Teck 90 wire Synprene™ RT5180 Flame retardant, LTB resistance Building & construction, industrial Synprene™ RT5180UV Flame retardant, LTB resistance Building & construction, industrial Synprene™ RT3870M Flame retardant, LTB resistance Building & construction, industrial 1.844.4AVIENT www.avient.com Copyright © 2023, Avient Corporation.
https://www.avient.com/products/engineered-polymer-formulations/flame-retardant-formulations
Maxxam™ FR Flame Retardant Formulations and Maxxam™ NHFR Non-Halogen Flame Retardant Formulations
Maxxam™ FR Flame Retardant Formulations and Maxxam™ NHFR Non-Halogen Flame Retardant Formulations
Maxxam™ Polyolefin Formulations
https://www.avient.com/sites/default/files/resources/Polyolefins%2520Product%2520Selection%2520Guide.pdf
11.866.POLYONE www.polyone.com MAXXAM™ FILLED & REINFORCED POLYOLEFINS PRODUCT SELECTION GUIDE 2 31.866.POLYONE www.polyone.com MAXXAM™ FILLED & REINFORCED POLYOLEFINS PolyOne manufactures a complete line of filled and reinforced polymer polyolefins for injection molding and blow molding.
Under the Maxxam™ brand, standard grades are formulated with any combination of calcium carbonate, glass fiber, mica and talc to provide a desired balance of properties, including stiffness, durability, impact resistance and heat resistance.
This product selection guide provides detailed information to help you select the Maxxam product that’s right for your application. 4 INJECTION MOLDING POLYPROPYLENE Product Code - - - PP5113 B44 F5134T2-4 PP5130 B63 F5134T4-1 Filler Percentage - % - 13 20 30 40 Tensile Strength Yield psi ASTM D638 5000 4800 4600 4500 MPa ISO 527 33 33 32 31 Tensile Elongation Yield % ASTM D638 6 4 3 2 ISO 527 Break % ASTM D638 60 30 15 10 ISO 527 Flexural Modulus 73°F (23°C) psi ASTM D790 300,000 360,000 400,000 460,000 MPa ISO 178 2300 2450 2900 3300 Notched Izod Impact 73°F (23°C) ft-lb/in ASTM D256 0.65 0.60 0.55 0.50 kJ/m2 ISO 180 3.50 3.3 3.00 2.75 Heat Deflection 66 psi °F ASTM D648 230 240 260 275 °C ISO 75 110 116 127 135 264 psi °F ASTM D648 130 140 150 175 °C ISO 75 54 60 66 79 Specific Gravity 73°F (23°C) - ASTM D792 0.99 1.04 1.15 1.25 ISO 1183 Linear Shrinkage Range 1/8 in wall % - 1.2–1.6 1.0–1.4 0.8–1.2 0.6–1.0 3.2 mm wall % - 1.2–1.6 1.0–1.4 0.8–1.2 0.6–1.0 Product Code - - - PP6113 A77-SM PP6120 B16-2 PP6130 B11 PP6135 B40-UV Filler Percentage - % - 13 20 30 35 Tensile Strength Yield psi ASTM D638 4350 3500 2600 3700 MPa ISO 527 30 24 18 26 Tensile Elongation Yield % ASTM D638 5 4 7 6 ISO 527 Break % ASTM D638 35 70 150 70 ISO 527 Flexural Modulus 73°F (23°C) psi ASTM D790 290,000 280,000 280,000 390,000 MPa ISO 178 2000 1950 1750 2700 Notched Izod Impact 73°F (23°C) ft-lb/in ASTM D256 0.7 2.7 4.5 0.65 kJ/m2 ISO 180 4.0 14 24 3.5 Heat Deflection 66 psi °F ASTM D648 239 215 225 250 °C ISO 75 115 102 107 123 264 psi °F ASTM D648 140 125 130 150 °C ISO 75 60 52 54 60 Specific Gravity 73°F (23°C) - ASTM D792 0.99 1.05 1.15 1.18 ISO 1183 Linear Shrinkage Range 1/8 in wall % - 1.1–1.5 .9–1.3 0.7–1.1 0.5–0.9 3.2 mm wall % - 1.1–1.5 .9–1.3 0.7–1.1 0.5–0.9 Maxxam™ Talc-Filled Copolymer Polypropylene • Scratch & mar resistant • UL approved • FDA certifiable • Natural, black or colors • High flow grades • UV stabilized • UL approved • FDA certifiable • Natural, black or colors • High flow grades • UV stabilized • Recycled content Maxxam™ Talc-Filled Homopolymer Polypropylene Offers a moderate level of impact strength and improved stiffness and heat deflection performance.
https://www.avient.com/sites/default/files/2023-12/Wire _ Cable Tri-fold Selection Guide_SPANISH.pdf
GUÍA DE SELECCIÓN DE PRODUCTOS SOLUCIONES PARA CABLE & ALAMBRE Materiales de Ingenieria Especializada Formulaciones para aislamiento, revestimiento y cross-web para el mercado de cable y alambre Syncure™ XLPE Formulaciones de Polietileno Reticulable • Curado al ambiente • Alto desempeño a la flama • Resistente al calor, el aceite, a la deformación por stress constante y la abrasión • Propiedades de baja temperatura • Baja inversión de capital • Alta velocidad de extrusión • Libre de DBDPE disponible • Boletinados por UL/CSA Maxxam™ FR Polipropileno con Retardante de Flama • Reemplaza al FEP para aislamiento • Desempeño a la flama • Cumplimiento a UL 444 yellow card • Baja constante dieléctrica • Alta velocidad de extrusión • Capacidad de extrusión para paredes delgadas Maxxam™ SY Polipropileno Espumado • Baja constante dieléctrica • Estructura celular uniforme • Resistencia al calor y la compresión • Facilidad del espumado mediante proceso químico Soluciones LSFOH ECCOH™ Baja Emisión de Humo y Libre de Halógenos • Mejora de la seguridad contra incendios • Baja emisión de humo, toxicidad y libre de halogenos (LSFOH) • Resistencia química ECCOH™ XL Soluciones para Cable Reticulado • Libre de halógenos, baja emisión de humos, baja toxicidad y anticorrosiva • Excelentes propiedades electricas y mecanicas • Facilmente procesable • Temperaturas de operación 90°C • Tecnologia de curado por humedad Synprene™ Elastómeros Termoplásticos Retardantes de Flama • Flexibilidad • Alta desempeño a la flama • Resistencia a baja temperatura • Resistencia química • Permite coloración FireCon™ CPE Polietileno Clorado Retardante de Flama • Resistencia en ambientes extremos • Propiedades de baja temperatura • Alta desempeño a la flama • Alta velocidad de extrusión • Resistencia a la luz del sol y rayos UV CARACTERISTICAS ESPECIFICACIONES ECCOH™ XL 8148 Libre de halógenos, baja emisión de humos, baja toxicidad, anticorrosivo EN50618 Syncure™ S100FH Flama horizontal UL 44 Syncure™ S100FH-XUV Flama horizontal, resistencia UV UL 44 Syncure™ S100FH-UV Flama horizontal, FV-1, resistencia UV UL 44, UL 4703 Syncure™ S100FV VW-1 UL 44 Syncure™ S100FV-UV VW-1, resistencia UV UL 44 Syncure™ S112NA Sin retardante a la flama CSA 22.2 Syncure™ S120NA Sin retardante a la flama NSF 61 Syncure™ S200FH Flama horizontal, libre de DBDPE UL 44 Syncure™ S200FV VW-1, libre de DBDPE UL 44 SISTEMAS PARA AISLAMIENTO DE CABLES DE BAJO VOLTAJE Cables de baja tensión • Desempeño a la flama • Resistencia al calor, aceite y abrasión • Buen desempeño a bajas temperaturas • Baja inversión de capital • Altas velocidades de procesamiento AISLAMIENTO Y CROSS-WEBS PARA CABLES DE CATEGORIA Los sistemas de cables de categoría nos proporcionan • Alternativas de cables FEP • Desempeño a la flama • Baja constante dieléctrica • Altas velocidades de extrusión y desempeño para pared delgada • Resistencia química • Desempeño a bajas temperaturas • Flexibilidad CARACTERISTICAS ESPECIFICACIONES Maxxam™ FR 0521-48 R1 Baja emisión de humo, libre de halógenos UL 444 Maxxam™ FR 0587-21 R3 Halogenado, y desempeño para cables plenum UL 444 Cables para fibra optica • Resistencia a ambientes extremos, químicos y a la exposición a luz del sol • Resistencia a bajas temperaturas (LTB) • Baja emisión de humos y toxicidad • Flexibilidad • Altas velocidades en extrusion CARACTERISTICAS ESPECIFICACIONES ECCOH™ 6649 UV Low DD Baja emisión de humos, Libre de halógenos Cubre las requerimientos de retardacia a la flama requeridos por el cliente Cables Coaxiales • Flexibilidad • Altas velocidades de extrusión • Baja constante dieléctrica • Estructura de celda uniforme • Resistencia al calor y a la deformación CARACTERISTICAS ESPECIFICACIONES Maxxam™ SY 89-22-7 Espumable Cubre las requerimientos de retardacia a la flama requeridos por el cliente SISTEMAS PARA CUBIERTA PARA CABLES DE DATOS Cubiertas para medio y bajo voltaje • Resistencia a ambientes extremos, ambientes químicos y degradación por rayos UV • Resistencia a bajas temperaturas (LTB) • Baja emisión de humos y toxicidad • Flexibilidad • Altas velocidades de extrusión • Fácilmente de colorear CARACTERISTICAS MERCADOS Y APLIACIONES FireCon™ CPE 30-33 RoHS Black Retardante a la flama, flexible Edificación & construcción, industrial, nuclear FireCon™ CPE 37-36 RoHS Black Retardante a la flama, flexible Edificación & construcción, industrial, nuclear FireCon™ CPE 30-20 RoHS Natural Retardante a la flama, flexible Edificación & construcción, industrial, nuclear ECCOH™ 5549 UV Baja emisión de humos, libre de halógenos, retardante a la flama Edificación & construcción, industrial ECCOH™ 6649 UV Low DD Baja emisión de humos, libre de halógenos, retardante a la flama Fibra optica, ductos ECCOH™ 5981 UV Baja emisión de humos, libre de halógenos, retardante a la flama Cables industriales, cables Teck 90 Synprene™ RT5180 Retardante a la flama, resistente a LTB Edificación & construcción, industrial Synprene™ RT5180UV Retardante a la flama, resistente a LTB Edificación & construcción, industrial Synprene™ RT3870M Retardante a la flama, resistente a LTB Edificación & construcción, industrial www.avient.com Copyright © 2023, Avient Corporation.
https://www.avient.com/resources/safety-data-sheets?page=4791
X Maxxam FR WC 0521-48 R1 N02G RoHS NAT
X Maxxam FR WC 0521-48 R1 8523 RoHS NAT
X Maxxam FR WC 0521-48 R1 5571 RoHS NAT