https://www.avient.com/idea/advanced-composites-ballistic-protection
Electrically non-conductive.
Fiberglass thermoset composites are inherently non-conductive to prevent arcing in electrically charged environments, such as utility substations.
https://www.avient.com/news/move-over-metal-polyone-launches-surround-emi/rfi-shielding-formulations
This portfolio of conductive thermoplastic materials shields sensitive electronics from both electromagnetic interference (EMI) and radio frequency interference (RFI).
With its integrated EMI/RFI shielding capabilities, Surround material adds depth to PolyOne’s existing electrically conductive and shielding material lineup.
https://www.avient.com/sites/default/files/2020-08/colormatrix-joule-fast-reheat-dispersions-tech-bulletin-a4.pdf
The additive is not soluble in MEG, but is very
thermally heat stable and at the low ppm addition
levels commonly used has no measurable impact
on the polymer process other than that coming
from the blue tint introduced into the polymer.
Other additives, such as Phosphoric Acid
(which is typically used as a thermal stabilizer)
can be used in conjunction with Joule RHB
additive and may be dosed at the same point
if process constraints dictate, but only when
using a separate lance to that used for the
reheat additive.
You have the responsibility to conduct full-scale end-product performance testing
to determine suitability in your application, and you assume all risk and liability arising from your use of the information and/or use or handling of any product.
https://www.avient.com/sites/default/files/2022-08/ColorMatrix Excelite Product Bulletin.pdf
Formulations
typically feature a combination of exothermic
and endothermic agents which, when under
thermal decomposition, cause gas to evolve
forming a cellular structure in the polymer matrix.
Excelite additives are not subject to significant
thermal exposure in the manufacturing process, so
the formulations are optimized for decomposition
during the customer process.
You have the responsibility to conduct full-scale end-product performance testing to determine
suitability in your application, and you assume all risk and liability arising from your use of the information and/or use or handling of any product.
https://www.avient.com/products/engineered-polymer-formulations/high-temperature-polymer-formulations/edgetek-pk-peek-formulations
Thermally stable Edgetek PK, with its excellent UV resistance, high purity and light weight, is an excellent high strength alternative to fluoropolymers, particularly in tougher environments.
https://www.avient.com/crtm-panels-0
Improved thermal insulation
https://www.avient.com/products/advanced-composites/pultrusion-and-continuous-filament-winding-technology/composite-heat-release-technology
This proprietary technology combines multiple layers of carbon fiber and ceramic composites applied to manufacturer-supplied steel bores, and leverages the principle of thermal inertia to accelerate heat dissipation from the barrel's bore.
https://www.avient.com/sites/default/files/2023-10/Syncure XLPE 200 Series DBDPE-free Grades Product Bulletin.pdf
You have the responsibility to conduct full-scale end-product performance testing
to determine suitability in your application, and you assume all risk and liability arising from your use of the information and/or use or handling of any product.
This literature shall NOT operate as permission, recommendation, or inducement to practice any patented invention without permission of the patent owner.
1.844.4AVIENT
www.avient.com
System
Syncure XLPE
S200FH
Syncure XLPE
S200FV
Applications
Building Wire, Tray Cable,
Service Entrance
Building Wire, Tray Cable,
Service Entrance
Specification UL 44 UL 44
Wire Type
RHW-2, RHW, RHH, XHHW-2,
XHH, XHHW, SIS
RHW, RHH, RHW-2
Components
78% S1054A
22% SC5400-0002 RoHS
MB ALT FR
50% S1054A
50% SC5400-0003 RoHS
MB ALT FR
Features Horizontal Flame, DBDPE-free VW-1, DBDPE-free
General Properties
Specific Gravity (g/cm3) 1.01 1.31
Hardness Shore D, 10sec 47 48
Gel % 68 70
Tensile Properties
Tensile Strength (psi) 2800 3200
Elongation % 400 470
Tensile Retention % 95 100
Elongation Retention % 90 93
Electrical
Dielectric Strength (V/mil) 1000 1200
Dielectric Constant 2.31 2.61
Dissipation Factor % 0.0012 0.0043
Thermal
Temperature Rating °C 90 90
Heat Deformation % 10 5
TECHNICAL PROPERTIES
https://www.avient.com/sites/default/files/2024-03/Edgetek PKE High Impact Formulations Technical Bulletin.pdf
You have the responsibility to conduct full-scale end-product performance testing
to determine suitability in your application, and you assume all risk and liability arising from your use of the information and/or use or handling of any product.
TECHNICAL
PROPERTIES(1)
TEST METHOD
Edgetek™
ET8900-0011
HI UV NAT
Edgetek™
ET8900-0012
HI UV White
Edgetek™
ET8900-0013
HI UV Black
Physical
Density/Specific Gravity ASTM D792 1.13 g/cm3 1.15 g/cm3 1.13 g/cm3
Molding Shrinkage - Flow ASTM D955 1.4–2% 1.4–2% 1.4–2%
Mechanical
Tensile Strength (Yield) ASTM D638 5,900 psi 5,800 psi 5,800 psi
Tensile Modulus(2) ASTM D638 169,000 psi 161,087 psi 176,000 psi
Flexural Modulus(3) ASTM D790 187,000 psi 190,985 psi 188,000 psi
Impact
Notched Izod Impact
73°F (23°C), 0.125 in
ASTM D256A 17.3 ft-lb/in 16.5 ft-lb/in 16.5 ft-lb/in
Notched Izod Impact
-22°F (-30°C), 0.125 in
ASTM D256A 3.2 ft-lb/in 3.0 ft-lb/in 3.3 ft-lb/in
Thermal (HDT)
66 psi (0.45 MPa), 0.125 in ASTM D648 121°C 135°C 129°C
NORTH AMERICA GRADES
(1) Data based on single lot of lab generated samples.
https://www.avient.com/sites/default/files/2021-03/lubrione-pke-product-bulletin.pdf
LubriOne
PKE formulations also offer improved chemical
resistance and thermal performance, plus reduced
flammability, over POM
You have the responsibility to conduct full-scale end-product performance testing
to determine suitability in your application, and you assume all risk and liability arising from your use of the information and/or use or handling of any product.