https://www.avient.com/sites/default/files/2021-06/colormatrix-select-brochure.pdf
COLORMATRIX SELECT WILL ENABLE:
• Immediate visibility of color
performance and cost data
for multiple formulation options
• On-demand color supply
• Full color choice with no minimum
order quantities
• Shorter development lead times
enabling faster market access and
multiple product introductions
• Assured global color consistency
• All the performance and process
efficiency advantages of ColorMatrix advanced
liquid colorants
MANUFACTURERS
TAKE CONTROL OF YOUR
COLOR SUPPLY
For manufacturers who use ColorMatrix Select will
be able to create and order color formulations online
in minutes.
CONVENTIONAL COLOR
DEVELOPMENT PROCESS
REDEFINED COLOR
DEVELOPMENT
Direct online access
to create new colors or view multiple color
formulations matching your specification
Full visibility
on color accuracy data performance,
price and regulatory status
Order samples
for dispatch within 24 hours
On-demand
color supply for production
Color Supplier
Designer
Brand
Target samples/
Target samples/
Matches
Trials
Manufacturer
ApprovalsApprovals Trials
Designer BrandManufacturer
ColorMatrix Select
Color Supplier
Designer
Brand
Target samples/
Target samples/
Matches
Trials
Manufacturer
ApprovalsApprovals Trials
Designer BrandManufacturer
ColorMatrix Select
Multiple rounds of sampling, trials and
approvals, usually over many weeks
COLORMATRIX
ADVANCED
LIQUID COLOR
SYSTEMS
Not all liquid colors are the same!
https://www.avient.com/sites/default/files/2025-01/Maxxam NHFR Non-Halogen Flame Retardant Polyolefins - Product Selector Guide EMEA.pdf
MAXXAM™ NHFR
NON-HALOGEN
FLAME RETARDANT
POLYOLEFINS
PRODUCT SELECTION GUIDE
Maxxam™ NHFR Polyolefins – Homopolymers
Disclaimer: The technical data provided here reflects the characteristic values of flame-retardant polypropylene materials and is not intended
as a product specification.
Product Name H15 H XF
V2 70
MF5200-5004
NHFR V2 HS
MF5200-5005
NHFR V2 RS H
MF5200-5006
NHFR V2 RS HS
H6 H XF
H20 H XF
H6 T/05 H XF
H6 T/10 H XF
H6 T/20 XF
H6 GF/10 XF
V070
H8 GF/20 XF
H12 GF/25 H
XF V0 70
H6 GF/30 XF
PE H XF
Polymer PP PE
Flammability V2 V2 V2 V2 V0 V0 V0 V0 V0 V0 V0 V0 V0 V0
UL Listed No No No No No No No No No No No No No Yes
Reinforcement Unfilled Unfilled Talc Talc Unfilled Unfilled Talc Talc Talc Glass Filled Glass Filled Glass Filled Glass Filled Unfilled
Density (g/cm3) 1.03 0.9 0.98 1.05 1.07 1.06 1.08 1.15 1.16 1.11 1.25 1.32 1.35 1
MFI,
230°C/2.16 kg 13 20 23 20 5.5 20 6 6 6 6 7 12 5.5
E-Modulus (Tensile
Modulus - Mpa) 1900 1500 2400 2600 2500 2500 2500 3000 3000 4300 6500 7500 8250 2000
Tensile Strength
(Mpa) 25 30 32 30 26 20 26 25 23 55 70 75 78 20
Elongation (%)
https://www.avient.com/sites/default/files/2021-10/maxxam-fr-category-cable-case-study.pdf
MAJOR W&C
PRODUCER
C A T E G O R Y C A B L E
• Flame retardance
• Replace fluorinated ethylene propylene (FEP)
• High tensile strength and high elongation at break
• Low dielectric constant (Dk) of 2.7-2.9 for data signal
integrity
• Satisfied stringent UL 444 requirements with
an FEP alternative to achieve cost savings
• Mitigated regulatory concerns with
comprehensive technical support during
testing and commercialization
• Met required melt strength parameters for
efficient profile extrusion
Maxxam™ FR Flame Retardant Polyolefin
Formulations
KEY REQUIREMENTS
WHY AVIENT?
https://www.avient.com/sites/default/files/2020-10/2020-gravi-tech-design-guide-.pdf
A larger processing window
will account for the lot to lot changes between
materials, without having to make process
changes.3
Setting the Beginning Variables
• Injection Pressure = Maximum of machine
- Should not be pressure limited
• Injection Velocity = Maximum of machine
- This is for the injection velocity curve
starting point
- If flashing is an issue start slower and
then increase
• Injection Cut-Off Time = 15 seconds
- This is only a limiting factor, needs to
be above 10 seconds for velocity graph
• Hold Pressure = 0
- Need to get 95% full part with a hold
pressure of 0
• Hold Time = 10-15 seconds
- Need to ensure gate is frozen
• Screw Speed = 90% of Maximum
- Unless shear sensitive material, if shear
sensitive, set RPMs to optimum
• Cooling Time = 10–15 seconds
• Shot Size = 50% of calculated part volume
• Decompression = .25in
• Transfer Position = High enough to ensure
a cushion
- Cushion size does not matter but there
must be a cushion to keep a constant
pressure on the melt during hold time
- Typically 0.25" is sufficient
• Back Pressure = 800-1000 plastic pressure
- 100–150 hydraulic pressure
- Unless specified by material data sheet
Determining Shot Size
The shot size should be determined by
calculating the combined volume of the parts
and the runner system.
If
the material is shear-sensitive, consult the
material data sheet or processing guide for
instructions to set recovery time
• The cooling time should only be 1–2 seconds
longer than the screw recovery time, unless
dictated by dimensional stability or part
thickness
Minimize Clamp Pressure
This step is done to reduce the amount of energy
used by the machine
https://www.avient.com/sites/default/files/2025-04/Supplier Code of Conduct FV_Eng.pdf
url=https%3A%2F%2Fwww.cbp.gov%2Ftrade%2Fforced-labor&data=05%7C01%7Cjacqueline.thomson%40avient.com%7Ca0427e02fa1b4b576fe208db6dac207e%7C7bc21b5c83b04482be9e2825d33c1759%7C0%7C0%7C638224359373869329%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C3000%7C%7C%7C&sdata=xxFjS7ADNXRYgriLexntpLUCOyllzLGactoRmj2EoCE%3D&reserved=0
https://www.avient.com/sites/default/files/2020-10/avient-conflict-minerals-policy-10.2020.pdf
https://www.avient.com/sites/default/files/2020-10/avient-conflict-minerals-policy-10.2020.pdf
• Engage in due diligence of supply chains by following
a nationally or internationally recognized due
diligence framework;
• Upon request, report to Avient on its due diligence
process and certify that 3TG metals supplied to
Avient from the Covered Countries are conflict free;
and
• Promptly report to Avient any supply chain changes
regarding the origin of 3TG metals or conflict status
Establish an information security and data privacy
system to protect Avient’s information, including
information of its customers and employees, from
being disclosed, changed, destroyed, or used for any
purpose other than the purpose for which it was
provided.
https://www.avient.com/sites/default/files/2021-06/fl.datasheet-strengthmembers.pdf
K58220T N/A Kevlar®
2480 LBs
(1125 KGs)
230 FT/LB
(154 M/KG)
Flat 2.81 mm N/A
Strength member in
cable application
Product ID
Polymer Jacket
Base Fiber
Break
Yield Geometry
Nominal
Diameter
Description
13.75mm
K/Hytrel
Hytrel Jacket Kevlar®
29000 LBs
(13154 KGs)
138 KGs/KM Round 13.75mm
Kevlar rope w/ Hytrel
12.5mm K/TPU TPU jacket Kevlar®
24000 LBs
(10885 KGs)
115 KGs/KM Round 12.5mm
Kevlar rope w/ Hytrel
7.87mm
K/MDPE
MDPE Jacket Kevlar®
24000 LBs
(10885 KGs)
50 KGs/KM Round 7.87mm
Kevlar w/ MDPE
.58mm C/PU TPU jacket Carbon
74 LBs
(33.6 KGs)
N/A Round/ Flat .58mm
Carbon w/ TPU
4.50mm
K/HDPE
HDPE jacket Kevlar®
2000 LBs
(907 KGs)
16 KGs/KM Round 4.06 mm
Kevlar w/ HDPE
POPULAR JACKETED STRENGTH MEMBERS
This data is provided for informational purposes only, and does not constitute a specification.
Uranusweg 3
8938 AJ Leeuwarden
The Netherlands
+31(0) 58 216 75 99
info@fiber-line.com
ABOUT FIBER-LINE®
NOTICE: The information and data contained herein do not constitute sales specifications.
https://www.avient.com/sites/default/files/2023-06/Supplier Code of Conduct FV.pdf
url=https%3A%2F%2Fwww.cbp.gov%2Ftrade%2Fforced-labor&data=05%7C01%7Cjacqueline.thomson%40avient.com%7Ca0427e02fa1b4b576fe208db6dac207e%7C7bc21b5c83b04482be9e2825d33c1759%7C0%7C0%7C638224359373869329%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C3000%7C%7C%7C&sdata=xxFjS7ADNXRYgriLexntpLUCOyllzLGactoRmj2EoCE%3D&reserved=0
• Engage in due diligence of supply chains by following
a nationally or internationally recognized due
diligence framework;
• Upon request, report to Avient on its due diligence
process and certify that 3TG metals supplied to
Avient from the Covered Countries are conflict free;
and
• Promptly report to Avient any supply chain changes
regarding the origin of 3TG metals or conflict status
Establish an information security and data privacy
system to protect Avient’s information, including
information of its customers and associates, from
being disclosed, changed, destroyed, or used for any
purpose other than the purpose for which it was
provided.
https://www.avient.com/sites/default/files/2024-12/PKE grades for Powersports Application Bulletin.pdf
Gasoline - 30% glass-filled (GF) grade, dry as molded (DAM), room temperature
Testing methodology is an adaptation from ASTM D543
• Reapply freshly soaked gauze pad every 24 hours to prevent from drying out
• Repeat for a total of 72 hours
• Tensile properties recorded
*Chemical resistance data for DEET, motor oil, glass cleaner, and sunscreen available upon request
KEY CHARACTERISTICS
Figure 1
Figure 2
3.34
3.84
3.63
1.96
2.21
0.99
3.43
3.86 3.93
1.76
3.49
2.01
3.26
3.66 3.74
1.45
1.06 0.989
2.98
3.99
3.41
1.41
1.07
0.88
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
30% LGF PKE 30% LGF PA6 30% LGF PA66 30% SGF PKE 30% SGF PA6 30% SGF PA66
Ft
-lb
/in
Notched Izod Impact
ASTM D256
23C DAM 23C Conditioned -40C DAM -40C Conditioned
1.47
1.37 1.37
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
Glass-Filled PKE Glass-Filled PA6 Glass-Filled PA66
g/
cm
3
Density of Polyketone vs Nylon
ASTM D792
LESS MOISTURE ABSORPTION THAN NYLON
30% Short Glass Fiber (SGF) Comparison
Moisture uptake, environmental chamber 62% RH, 70°C
SIMILAR DENSITY TO NYLON
ASTM D792
COMPARABLE AND CONSISTENT IMPACT PERFORMANCE*
Notched Izod Impact (ASTM D256) of LGF and SGF for DAM and
Conditioned Materials
*3,000 hr weathering data available upon request
KEY CHARACTERISTICS
1.844.4AVIENT
www.avient.com
Copyright © 2024, Avient Corporation.
https://www.avient.com/sites/default/files/2024-10/Avient_CodeConduct_2024_INDO2.pdf
Ini termasuk cara Anda mengumpulkan,
menggunakan, menyimpan, membagikan, dan melindungi atau
menghapus atau membuang data pribadi.
Perinciannya tercakup dalam Kebijakan Privasi dan Perlindungan
Data Global yang tersedia di The Loop, dalam bagian Personalia &
Departemen, Kebijakan Etika & Perusahaan.
Anda harus
membiasakan diri dan mematuhi kebijakan, prosedur, dan protokol
perusahaan tentang keamanan, manajemen informasi, dan keamanan
siber, termasuk, tetapi tidak terbatas pada kebijakan, prosedur, dan
protokol perusahaan yang tercantum dalam Kebijakan Penggunaan
Sistem Informasi Avient, Kebijakan Privasi dan Perlindungan Data
Global, serta Kebijakan Tanggap Insiden Siber dan Data.
https://www.avient.com/sites/default/files/2024-08/PCF One-pager.pdf
This certification
ensures that our tool meets rigorous criteria and
addresses relevant safety aspects, providing you
with reliable and accurate data.