https://www.avient.com/sites/default/files/2023-01/Carbon Footprint Infographic.pdf
Carbon Footprint Infographic
Downstream
COMMON TERMINOLOGY
Carbon Dioxide Equivalent (CO2e):
A common way to measure and
report greenhouse gas (GHG)
emissions such as carbon dioxide
(CO2), methane (CH4), nitrous oxide
(N2O), hydrofluorocarbons (HFCs),
perfluorocarbons (PFCs), and
sulphur hexafluoride (SF6)
Emission Standards: The
classification of emissions across
the supply chain
Scope 1: Direct emissions from
sources that are owned or
controlled by an organization (e.g.,
company-owned vehicles, process
emissions, and on-site heating)
Scope 2: Indirect emissions from
purchased indirect sources, such
as the production of electricity and
steam for an organization’s use
Scope 3: Indirect emissions from
sources up and down the supply
chain, including materials,
transportation of goods, and the
processing, use, and end-of-life
treatment of sold products
Cradle-to-Gate: Carbon impact of a
product from raw materials and
product manufacturing
Cradle-to-Grave: Carbon impact
and analysis across the entire life
cycle of a product from raw materials
to disposal
© 2023 Avient • www.avient.com • 1.844.4AVIENT
Raw Materials
Supply Chain
UNDERSTANDING CARBON FOOTPRINT
CO2e
Transportation
End-of-Life
Treatment
Processing
of Goods
Use of
Products
Transportation
Chemical
Processing
Cradle-to-Gate (B2B)
Cradle-to-Grave (B2C)
SCOPE 3
INDIRECT
SCOPE 3
INDIRECT
Electricity
Steam
Company
Facilities
Company-Owned
Vehicles
SCOPE 1
DIRECT
SCOPE 2
INDIRECT
Reporting CompanyUpstream
https://www.avient.com/sites/default/files/2024-11/Terms and Conditions of Sale for Canada %28French Translation%29.pdf
Si cela est nécessaire pour
permettre à une autorité ou un organisme compétent de vérifier
le respect des lois en matière de contrôle du commerce,
l’acheteur doit, à la demande du vendeur, fournir rapidement au
vendeur tous les renseignements relatifs à l’opération en
question, notamment en ce qui concerne le client final, la
destination précise et l’utilisation prévue des produits, ainsi que
tout autre renseignement pertinent concernant les lois en matière
de contrôle du commerce en vigueur.
L’acheteur s’engage à
indemniser le vendeur et à le dégager de toute responsabilité (y
compris les amendes ou les honoraires d’avocat) engagée par le
vendeur à l’égard de toute activité d’exportation ou de
réexportation par l’acheteur en violation de ses obligations aux
termes des lois en matière de contrôle du commerce applicables.
Le vendeur a le droit de mettre fin à
une confirmation de commande avec prise d’effet immédiate si,
à tout moment avant la livraison, une personne ou un groupe de
personnes qui ne sont pas liées aux personnes qui contrôlent
l’acheteur à la date de la confirmation de commande acquiert le
contrôle de l’acheteur au moyen de la propriété de titres
comportant droit de vote ou autrement.
https://www.avient.com/sites/default/files/2022-03/Trilliant HC Electrically Conductive Formulations for Pipette Tips Application Bulletin.pdf
In
some applications, conductivity is needed to avoid
static discharge that could give a false or inaccurate
reading.
Some of the information arises from laboratory work with small-scale equipment which may not provide a reliable
indication of performance or properties obtained or obtainable on larger-scale equipment.
https://www.avient.com/sites/default/files/2020-10/wire-cable-1-pager.pdf
Some of the information arises from laboratory work with small-scale equipment which may not provide a reliable
indication of performance or properties obtained or obtainable on larger-scale equipment.
Some of the information arises from laboratory work with small-scale equipment which may not provide a reliable
indication of performance or properties obtained or obtainable on larger-scale equipment.
https://www.avient.com/sites/default/files/2020-08/stan-tone-epx-product-bulletin.pdf
% Pigment Specific Gravity Color Index Lightfastness
WHITE
10EPX03 Titanium Dioxide, Rutile 57 1.95 PW-6 I/O
YELLOW
12EPX01 Diarylide AAOT GS 25 1.22 PY-14 I
12EPX03 Diarylide HR RS 20 1.2 PY-83 I/O (Mass)
13EPX02 Isoindolinone RS 30 1.3 PY-110 I/O
13EPX03 Benzimidazolone GS 40 1.27 PY-151 I/O (Mass)
81EPX01 Iron Oxide 40 1.62 PY-42 I/O
ORANGE
15EPX03 Benzimidazolone 30 1.26 PO-36 I/O
RED
23EPX04 Quinacridone BS 25 1.21 PV-19 I/O
23EPX06 Specialty Naphthol BS 30 1.21 PR-170 I/O (Mass) C
25EPX01 Red 2B, Ca Salt Bs 24 1.27 PR-48:2 I/O (Mass)
28EPX01 Red 2B, Ba Salt YS 23 1.29 PR-48:1 I/O (Mass)
82EPX01 Iron Oxide, Light BS 40 1.67 PR-101 I/O
82EPX02 Iron Oxide, Dark BVS 40 1.68 PR-101 I/O
82EPX04 Iron Oxide, Light VYS 40 1.67 PR-101 I/O
BLUE
40EXP03 Phthalocyanine GS 25 1.25 PB-15:3 I/O
40EXP05 Phthalocyanine RS 25 1.25 PB-15:3 I/O
42EXP02 Ultramarine 50 1.54 PB-29 I/O
49EXP01 Cobalt 50 1.83 PB-28 I/O
GREEN
50EPX02 Phthalocyanine BS 18 1.34 PG-7 I/O
50EPX03 Phthalocyanine YS 25 1.42 PG-7 I/O
59EPX01 Chromium Oxide 40 1.64 PG-17 I/O
VIOLET/MAGENTA
24EPX03 Quinacridone Violet 15 1.2 PV-19 I/O
24EPX04 Ultramarine Violet 50 1.66 PV-15 I/O
24EPX05 Quinacridone Magenta 20 1.21 PR-122 I/O
24EPX06 Benzimidazolone 20 1.2 PV-32 I/O
24EPX07 Carbazole Violet 15 1.2 PV-23 I/O
BROWN/TAN
83EPX01 Iron Oxide, Light 39 1.64 PBr-6 I/O
83EPX02 Iron Oxide, Dark 40 1.66 PBr-6 I/O
BLACK
90EPX01 Furnace - High Jet 14 1.23 PBk-7 I/O
90EPX04 Furnace - Medium 20 1.25 PBk-7 I/O
90EPX05 Iron Oxide 50 1.77 PBk-11 I/O
EPX
RS = Red Shade
YS = Yellow Shade
VYS = Very Yellow Shade
BS = Blue Shade
VBS = Very Blue Shade
GS = Green Shade
HR = Heat-Resistant
LIGHTFASTNESS
I = Indoor Only
I/O = Indoor or Outdoor
Mass = Outdoor Masstone
Application Only
C = Some Caution Advised
www.avient.com
Copyright © 2020, Avient Corporation.
Some of the information arises from laboratory work with small-scale equipment which may not provide a reliable
indication of performance or properties obtained or obtainable on larger-scale equipment.
https://www.avient.com/sites/default/files/2020-10/tpes-for-automotive-hvac-product-bulletin.pdf
Some of the information arises from laboratory work with small-scale equipment which may not provide a reliable
indication of performance or properties obtained or obtainable on larger-scale equipment.
Some of the information arises from laboratory work with small-scale equipment which may not provide a reliable
indication of performance or properties obtained or obtainable on larger-scale equipment.
https://www.avient.com/sites/default/files/2020-09/sem-stain-resistant-technical-bulletin.pdf
Some of the information arises from laboratory work with small-scale equipment which may not provide a reliable
indication of performance or properties obtained or obtainable on larger-scale equipment.
Some of the information arises from laboratory work with small-scale equipment which may not provide a reliable
indication of performance or properties obtained or obtainable on larger-scale equipment.
https://www.avient.com/sites/default/files/2024-11/ColorMatrix Lactra LX Product Bulletin.pdf
Some of the information arises from laboratory work with small-scale equipment which may not provide a reliable
indication of performance or properties obtained or obtainable on larger-scale equipment.
Some of the information arises from laboratory work with small-scale equipment which may not provide a reliable
indication of performance or properties obtained or obtainable on larger-scale equipment.
https://www.avient.com/sites/default/files/2020-08/sem-edgetek-application-bulletin.pdf
Some of the information arises from laboratory work with small-scale equipment which may not provide a reliable
indication of performance or properties obtained or obtainable on larger-scale equipment.
Some of the information arises from laboratory work with small-scale equipment which may not provide a reliable
indication of performance or properties obtained or obtainable on larger-scale equipment.
https://www.avient.com/sites/default/files/2020-10/edgetek-peek-product-selection-guide.pdf
Some of the information arises from laboratory work with small-scale equipment which may not provide a reliable
indication of performance or properties obtained or obtainable on larger-scale equipment.
Some of the information arises from laboratory work with small-scale equipment which may not provide a reliable
indication of performance or properties obtained or obtainable on larger-scale equipment.