https://www.avient.com/sites/default/files/2024-03/Cesa Stat Antistatic Additives Product Bulletin.pdf
They are compatible with a variety of resin systems,
as well as many processes including extrusion,
injection molding, blow molding, and calendering.
PRODUCT BULLETIN
KEY CHARACTERISTICS
• Eliminates electric charges to maintain good
product appearance
• Creates safer, static-dissipated parts for
electronics, packaging, automotive, and
military applications
• Improves product appeal by reducing static
charge-related dust accumulation
• Reduces the risk of a potential fire hazard in
product environments
• Reduces cycle times, maximizes throughput,
and lowers operating costs
• Can be combined with other additives or
colorants into a single masterbatch
• Compatible with a variety of processes
including blow molding, injection molding,
extrusion, and film processing
• FDA-approved and bio-based formulations
available
MARKETS AND APPLICATIONS
Cesa Stat Antistatic Additives are suitable for any
thermoplastic application that could benefit from
reduced static buildup, including:
• Automotive under-the-hood components
• Automotive dashboards
• Electrical connectors & components
• Electronic components
• Military components
• Consumer packaging
ARE YOU IN A BATTLE WITH STATIC?
https://www.avient.com/sites/default/files/2025-01/SEM MCCB Phase Barrier Application Bulletin.pdf
ONFLEX S HF
ONFLEX S HF &
HF 7001
SYNPRENE RT-5180
ROHS NATURAL
Commercial
Availability Asia Europe Americas
RoHS
Compliant Yes Yes Yes
Color Natural Natural Natural
Hardness 70/80/90 Shore A 50/70/90 Shore A 80 Shore A
Flame Retardant
Package Non-Halogenated Non-Halogenated Halogenated
Processing
Method
Injection Molding
Extrusion
Injection Molding
Injection Molding
Extrusion
ELECTRICAL & ELECTRONICS SOLUTIONS
REDUCE POSSIBILITY OF MOLDED
CASE CIRCUIT BREAKER FAILURE
WITH TPE PHASE BARRIERS
www.avient.com
Copyright © 2025, Avient Corporation.
https://www.avient.com/sites/default/files/2024-09/Chemical Resistance Technical Bulletin %281%29.pdf
MEDICAL DEVICE DISINFECTION—HOW TO PREVENT
CRACKING AND CRAZING
Understanding polymer performance is key to minimizing
disinfectant-related failures
DISINFECTANT-RELATED DAMAGE
ON POLYMER HOUSINGS
Strong chemicals used to reduce hospital-
acquired infections can damage equipment
and result in material failures, such as:
• Stress cracking
• Crazing
• Discoloration
CHEMICAL RESISTANCE REQUIREMENTS
VARY BY ENVIRONMENT
• Patient/exam rooms
• Operating and radiology rooms
• Reception areas
• Home (patient equipment & devices)
Healthcare devices must perform flawlessly in a myriad of challenging environments and engineers must
be certain their devices can withstand increasingly potent disinfectants, which have begun to outstrip
the performance of traditional polymers.
Additionally, the wide variability of environments that medical
devices might see, which can range from home to hospital, mean devices must be able to withstand varying
disinfectant strengths, exposure levels and frequencies.
Whether you are designing for a medical device housing or a surgical device in the operating room, we offer
solutions to meet a wide variety of performance specifications and application needs.
https://www.avient.com/industries/consumer/consumer-discretionary/outdoor-recreation/exercise-fitness
Medical Tubing
Medical Packaging
Medical Packaging
https://www.avient.com/sites/default/files/2024-11/Stan-Tone HC Plus Product Bulletin_0.pdf
These
USP-compliant colorants are available in liquid
silicone rubber (LSR) and high consistency silicone
rubber (HCR) forms and can be customized for
specific medical uses.
These high-quality silicone dispersions
excel in sterilization capabilities while maintaining
low toxicity, making them ideal for medical
applications.
KEY CHARACTERISTICS
• Meets USP Class VI standards
• Biocompatible
• Provides lightfastness, chemical resistance,
and heat stability
• Available in standard single pigment or custom
multi-pigment colors
• LSR and HCR options available
TARGET APPLICATIONS
Stan-Tone HC Plus silicone dispersions are suitable
for a variety of healthcare applications including:
• Catheters and medical tubing
• Medical and surgical equipment
• Labware and diagnostic devices
• Specialty medical devices and wearables
Product
Code
Pigment Type
% Pigment
(approx.)
https://www.avient.com/sites/default/files/2024-11/Stan-Tone HC Plus Product Bulletin.pdf
These
USP-compliant colorants are available in liquid
silicone rubber (LSR) and high consistency silicone
rubber (HCR) forms and can be customized for
specific medical uses.
These high-quality silicone dispersions
excel in sterilization capabilities while maintaining
low toxicity, making them ideal for medical
applications.
KEY CHARACTERISTICS
• Meets USP Class VI standards
• Biocompatible
• Provides lightfastness, chemical resistance,
and heat stability
• Available in standard single pigment or custom
multi-pigment colors
• LSR and HCR options available
TARGET APPLICATIONS
Stan-Tone HC Plus silicone dispersions are suitable
for a variety of healthcare applications including:
• Catheters and medical tubing
• Medical and surgical equipment
• Labware and diagnostic devices
• Specialty medical devices and wearables
Product
Code
Pigment Type
% Pigment
(approx.)