https://www.avient.com/technical-tips-transfer-printing
Pre-heat paper in a dryer to 260 F (132 C), then print immediately to maintain registration, or cover with plastic sheeting.
Oven temperature should be set in the region of 100 F (38 C).
Continual temperatures of 100 F (38 C) or more may result in the transfer ink not easily releasing from the paper.
https://www.avient.com/sites/default/files/2025-01/Glasforms Dowel Bar Application Overview.pdf
Matrix Resin Fiber Reinforcement Fiber Content, by Weight (%) Epoxy E-CR or E-Glass >70% MATERIAL TECHNICAL DATA Property Test Procedure Rod Diameter 1.25 in (31.75 mm) 1.50 in (38.10 mm) Glass Transition Temp (Tg) ASTM 1356 100°C Minimum 100°C Minimum Water Absorption 24 hours at 50°C (122°F) ASTM D570 0.03% 0.03% Short Beam Strength (ILSS) ASTM 2344 8,400 psi (58 MPa) 9,200 psi (64 MPa) Transverse Shear Strength ASTM 7617 23,400 psi (160 MPa) 24,640 psi (170 MPa) Traceability Lot number shall be clearly marked on each package/shipment.
TYPICAL PROPERTIES Tensile Strength Tensile Modulus Flexural Strength Compressive Strength ASTM D3916 ASTM D3916 ASTM D790 ASTM D695 110 ksi (760 N/mm²) 6.0 psi x 106 (41 kN/mm²) 130 ksi (900 N/mm²) 85 ksi (590 N/mm²) TYPICAL EQUIVALENT MECHANICAL PERFORMANCE*
https://www.avient.com/sites/default/files/2023-11/2023 Syncure Wire and Cable Product Selection Guide_SPANISH.pdf
Syncure™ XLPE Formulaciones Para Polietileno Reticulable PARA CABLES DE BAJA TENSIÓN GUÍA DE SELECCIÓN DE PRODUCTO Syncure™ XLPE POLIETILENO RETICULABLE POR HUMEDAD PARA AISLAMIENTO PARA CABLES DE BAJA TENSIÓN SISTEMA S100FH S100FH-XUV S100FH-UV S100FV S100FV-UV S112NA S120NA S200FH S200FV Aplicaciones Cable para construcción, bandeja de cables Cable para construcción, bandeja de cables Cable fotovoltaico (PV) Cable para construcción, bandeja de cables Cable para construcción, bandeja de cables Cable para construcción, Teck-90 Tuberia Cable para edificaciones, tray cables, cables de servicio Cable para edificaciones, tray cables, cables de servicio Especificaciones UL 44 UL 44 UL 44, UL 4703 UL 44 UL 44 CSA 22.2 Usable para NSF 61 UL 44 UL 44 Tipo de alambre XHHW-2, RHW-2, USE-2, SIS XHHW-2, RHW-2, USE-2, SIS XHHW-2, RHW-2, USE-2, SIS, PV XHHW-2, RHW-2, SIS XHHW-2, RHW-2, USE-2, SIS, PV RW-90, Teck-90 – RHW-2, RHW, RHH, XHHW-2, XHH, XHHW, SIS RHW, RHH, RHW-2 % de componentes 83% S1054A 17% V0022G RoHS 83% S1054A 17% V0022G-UV RoHS 70% S1054A 30% V0022G-UV RoHS 50% S1054A 50% V0044G RoHS 50% S1054A 50% V0044G-UV RoHS 95% S1054A 5% S1000B 95% S1016A 5% S1037B 78% S1054A 22% SC5400-0002 RoHS MB ALT FR 50% S1054A 50% SC5400-0003 RoHS MB ALT FR Caracteristicas Flama horizontal Flama horizontal, resistencia UV, posibilidad de colorear Flama horizontal, flama FV-1, resistencia UV, posibilidad de colorear VW-1 VW-1, resistencia UV, posibilidad de colorear Sin retardante a la flama Para aplicaciones de tuberia Flama horizontal, libre de DBDPE VW-1, libre de DBDPE PROPIEDADES GENERALES Gravedad Específica 1.01 1.02 1.10 1.31 1.31 0.92 0.95 1.01 1.31 Rigidez Shore D, 10 Segundos 47 47 47 48 48 47 59 47 48 % de Contenido de Gel 68 68 70 70 70 72 72 68 70 PROPIEDADES DE RESISTENCIA A LA TRACCIÓN Resistencia a la Tracción (psi) 2800 2500 2500 3200 2650 2800 4500 2800 3200 % de Elongación 400 400 400 470 540 400 80 400 470 % de Retención de Tracción 100 100 97 110 110 95 75 95 100 % de Retención de Elongación 90 90 94 100 100 90 75 90 93 PROPIEDADES ELÉCTRICAS Resistencia Dieléctrica (V/mil) 1000 1400 1400 1200 1200 1000 –– 1000 1200 Constante Dieléctrica 2.31 2.45 2.61 2.61 2.61 2.24 2.1 2.31 2.61 % de Factor de Disipación 0.0012 0.0080 0.008 0.0043 0.0043 0.0008 0.002 0.0012 0.0043 PROPIEDADES TÉRMICAS Condiciones Nominales de Temperatura en °C 90 90 90 90 90 90 125 90 90 % de Deformación Térmica 10 10 5 5 5 10 10 10 5 La cartera Syncure XLPE es un sistema de dos pasos de Polietileno reticulable por humedad, injertado con Silano.
CARACTERÍSTICAS • Curación a temperatura ambiente • Pirorresistencia • Resistente al calor, el aceite, la fluencia lenta y la abrasión • Propiedades de baja temperatura • Temperature rating por arriba de 125°C • Baja inversión de capital • Alta velocidad de extrusión • Incluidos en boletines de UL/CSA www.avient.com Copyright © 2023, Avient Corporation.
https://www.avient.com/sites/default/files/2020-07/entry-door-1-page-case-study.pdf
Entry door 1-page case study EXTERIOR DOORS R E S I D E N T I A L & C O M M E R C I A L Reinforcement of steel to reduce weight and provide: • Corrosion resistance • Improved dent resistance to withstand windborne debris • Structural performance to meet regional wind load requirements • Improved resistance to corrosion and moisture degradation • Increased dent resistance up to 60% vs. unreinforced metal • Enabled reduction in thickness of sheet metal while maintaining structural performance Polystrand™ PETG continuous fiber reinforced composite laminate thermally bonded to steel door skin KEY REQUIREMENTS WHY AVIENT?
https://www.avient.com/sites/default/files/2023-01/Nymax Motorcycle Trunk Application Snapshot.pdf
TRANSPORTATION OEM A F T E R M A R K E T M O T O R C Y C L E T R U N K L I D & B A S E • Maintain physical performance of incumbent 30% glass fiber nylon while improving sink and warp issues • Black with an easy-to-paint surface • UV resistant • Collaborated to rapidly provide an alternative material with excellent balance of physical properties and durability • Achieved comparable performance while improving paintability • Quickly provided samples and offered on-site application development and technical support at molding trials Nymax™ Glass and Mineral Fiber Reinforced Nylon 6 Formulation KEY REQUIREMENTS WHY AVIENT?
https://www.avient.com/sites/default/files/2021-04/versaflex-hc-bt218-biopharmaceutical-tubing-case-study.pdf
MEDICAL TUBING EXTRUDER B I O P H A R M A C E U T I C A L T U B I N G • Low leachables & extractables • Great tensile performance and kink resistance • Good thermal weldability • Excellent clarity and medical blue tint • ISO 10993-4 & 5, USP Class VI & Animal Derivative Free (ADF) • Supplied drop-in material replacement to overcome supply constraints of incumbent TPE • Offered a lower extractable profile than comparable materials in the market • Enabled easy material transition without changes in tooling or thermal welding machine settings • Formulated solution with proprietary additives to provide clarity and prevent yellowing after sterilization Versaflex™ HC BT218 Thermoplastic Elastomer KEY REQUIREMENTS WHY AVIENT?
https://www.avient.com/knowledge-base/article/understanding-tpe-material-and-performance-enabling-5g-technologies?rtype[]=1164
The ASTM D2520 standard is split into three parts: Part A for shorted transmission line method, Part B for waveguide cavities, and Part C for general examination.
Using the test method reference from ASTM D2520 Part C, we generated repeatable data on the samples of four select formulations at the same four thicknesses, recording the average and median values for both dielectric constant (Dk) and dissipation factor (Df).
https://www.avient.com/knowledge-base/article/understanding-tpe-material-and-performance-enabling-5g-technologies?ind[]=21508
The ASTM D2520 standard is split into three parts: Part A for shorted transmission line method, Part B for waveguide cavities, and Part C for general examination.
Using the test method reference from ASTM D2520 Part C, we generated repeatable data on the samples of four select formulations at the same four thicknesses, recording the average and median values for both dielectric constant (Dk) and dissipation factor (Df).
https://www.avient.com/knowledge-base/article/understanding-tpe-material-and-performance-enabling-5g-technologies
The ASTM D2520 standard is split into three parts: Part A for shorted transmission line method, Part B for waveguide cavities, and Part C for general examination.
Using the test method reference from ASTM D2520 Part C, we generated repeatable data on the samples of four select formulations at the same four thicknesses, recording the average and median values for both dielectric constant (Dk) and dissipation factor (Df).
https://www.avient.com/sites/default/files/2024-10/ECCOH_ LSFOH 5983 Formulation - Power Cable Jacket - Application Snapshot.pdf
CABLE MANUFACTURER J A C K E T F O R P O W E R C A B L E • High tear resistance > 11 N/mm • High environmental stress cracking resistance (ESCR) • Cost efficient solution • Hot pressure resistance above 80°C • Provided a jacket solution that complies with LTS1 requirements as per the BS 7655-6.1 standard • Enabled use in over-armored cables operating at a maximum conductor temperature of 90°C • Supported our customer in optimizing the processing of the new material ECCOH LSFOH 5983 Formulation KEY REQUIREMENTS WHY AVIENT?