https://www.avient.com/sites/default/files/2023-01/Mevopur Standard Colors Product Bulletin _ Color Card.pdf
KEY CHARACTERISTICS
• Globally harmonized formulations are
manufactured at four ISO 13485 certified
medical sites, providing global consistency
and increased security of supply
• Documented change control available
• A range of standard colors eliminates color
matching to expedite development time
• The portfolio includes compliant colors for
use in:
- Needle hub applications: ISO 6009
- Ophthalmic container closures
(American Academy of Ophthalmology)
REGULATORY SUPPORT
• A library of pre-tested raw materials including:
- ISO 10993-1 and USP biological
evaluation
- European Pharmacopeia 3.1.3/3.1.5
(polyolefin)
- USP (polyethylene)
- ICH Q3D elemental impurities
• Registered Drug Master File (Type III) and/or
Device Master File
• Food contact established with FDA/EU*
HEALTHCARE APPLICATIONS
• Medical devices such as catheters, surgical and
dental instruments, and drug delivery devices
• Pharmaceutical packaging including vials
and bottles
• Diagnostics for blood analysis or In Vitro
Diagnostics (IVD)
PRODUCT BULLETIN & COLOR CARD
* FDA/EU compliance information available upon request; exceptions may occur
Color Pantone Reference PE Base PP Base
Transparent
PP Base PEBA Base PC Base
Transparent
PC Base* ABS Base*
White — PE0M176031 PP0M176045 ** AH0M415001 NC0M176058 ** SB0M665206
Yellow 102C PE1M176076 PP1M176060 PP1M176062 AH1M415002 NC1M176058 NC1M176059 SB1M664958
Orange 158C PE2M176044 PP2M176046 ** ** NC2M176044 NC2M664912 SB2M664939
Red 199C PE3M176131 PP3M176111 PP3M176113 AH3M415002 NC3M176116 NC3M176122 SB3M665037
Pink 196C PE3M176130 PP3M176109 ** AH3M415001 NC3M176117 NC3M665052 SB3M665039
Violet 2593C PE4M176023 PP4M176036 PP4M176039 AH4M415001 NC4M176038 NC4M176044 SB4M664978
Light Blue 292C PE5M176155 PP5M176169 ** AH5M415003 NC5M176142 ** SB5M665402
Mid Blue 285C PE5M176154 PP5M176171 PP5M176175 AH5M415002 NC5M176143 NC5M176146 SB5M665404
Dark Blue 288C PE5M176153 PP5M176173 ** ** NC5M176144 ** SB5M665406
Light Green 346C PE6M176128 PP6M176111 ** ** NC6M176118 ** SB6M665070
Bluish Green 3145C PE6M176126 PP6M176115 ** ** NC6M176119 ** SB6M665068
Medium Green 348C PE6M176127 PP6M176113 PP6M176118 AH6M415001 NC6M176120 NC6M176121 SB6M665072
Dark Gray 425C PE7M176066 PP7M176091 PP7M176094 ** NC7M176124 ** SB7M665297
Mid Gray Cool Gray 5C PE7M176067 PP7M176089 ** AH7M415001 NC7M176125 NC7M665175 SB7M665295
Beige 7502C PE8M176048 PP8M176058 ** ** NC8M176058 ** SB8M664871
Brown 463C/731C PE8M176049 PP8M176060 ** ** NC8M176059 ** SB8M664869
Black Black C PL9M176008 PP9M176017 ** ** NC9M176008 NC9M176009 SB9M664896
Colors may vary from actual color shown.
For more detailed information on Mevopur uses and restrictions see www.avient.com/healthcare-use-limitations-mevopur-products or contact your Avient sales representative.
1.844.4AVIENT
www.avient.com
https://www.avient.com/sites/default/files/2022-12/Mevopur Healthcare Colorants and Formulations for Needle Hubs Application Bulletin.pdf
KEY CHARACTERISTICS
• Manufactured at four ISO 13485 certified sites,
providing global consistency and increased
security of supply
• Documented change control beyond CAS
number, reducing risk of change
• Non-phthalate and formulated without
animal-derived substances
• Color can be combined with additives to
enhance performance and protection
REGULATORY SUPPORT
• Raw materials tested to:
- ISO 10993-1 and USP biological
evaluation
- European Pharmacopeia 3.1.3/3.1.5
(polyolefin)
- USP (polyethylene)
- ICH Q3D elemental impurities
• Registered Device Master File
• Food contact established with FDA/EU*
NOMINAL
OUTSIDE
DIAMETER OF
NEEDLE (MM)
COLOR
DESCRIPTION RAL PANTONE
TRANSPARENT
PRODUCT CODE
OPAQUE
PRODUCT
CODE
0.4 Medium Grey 7035 423 C PP7M665125 PP7M665127
0.45 Brown 8017 7588 C PP8M665294 PP8M665296
0.5 Orange 2003 173 C PP2M665298 PP2M665300
0.55 Medium Purple 4005 7676 C PP4M665290 PP4M665292
0.6 Deep Blue 5010 288 C PP5M665894 PP5M665896
0.7 Black 9005 Black C PP9M664950 PP9M664952
0.8 Deep Green 6001 7483 C PP6M665687 PP6M665689
0.9 Yellow 1021 115 C PP1M665211 PP1M665213
1.1 Cream 1015 7401 C PP0M665290 PP0M665292
1.2 Pink 3015 502 C PE3M665725 PP3M665727
Healthcare use limitations apply—see below.
For more detailed information on Mevopur uses and restrictions see www.avient.com/healthcare-use-limitations-mevopur-products or contact your Avient sales representative.
1.844.4AVIENT
www.avient.com
https://www.avient.com/sites/default/files/2022-12/Mevopur Healthcare Functional Additives Medical Devices Application Bulletin.pdf
KEY CHARACTERISTICS
• Manufactured at four ISO 13485 certified sites,
providing global consistency and increased
security of supply
• Documented change control beyond CAS
number reducing risk of change
• Non-phthalate and formulated without animal-
derived substances
• Available for use in a wide range of polymers
including polyolefins, styrenics, polycarbonate
and alloys, polyester, POM
• Functionality can be combined with colorants
into convenient combination concentrates and
ready-to-use formulations
REGULATORY SUPPORT
• Raw materials tested to:
- ISO 10993-1 and USP biological
evaluation
- European Pharmacopeia 3.1.3/3.1.5
(polyolefin)
- USP (polyethylene)
- ICH Q3D elemental impurities
• Registered Drug Master File (Type III) and/or
Device Master File
• Food contact established with FDA/EU*
APPLICATION BULLETIN
* FDA/EU compliance information available upon request
FUNCTIONALITY TARGET APPLICATIONS
DRUG
DELIVERY
DEVICES
SYRINGES &
NEEDLES DIAGNOSTICS CATHETERS
Clarifying PP
Sorbitol-free for transparent
applications with reduced migration
and improved thermal stability
Lubricant—
permanent/
non-migrating
Fast acting reduction in friction
for wide variety of polymers such
as PP, ABS, POM, PC
Protection from
UV in transparent
applications for PP,
PE, PETG, COP
UV blocking in 290-450nm with
no impact on clarity; can be
combined with colors (e.g., amber)
Antistatic ready-to-
use solution for PP,
ABS, PC/ABS
Permanent/non-migrating;
fast decay time independent
of % relative humidity
Gamma/e-beam
sterilization
protection of the
polymer
Preserving the properties of
PP and COC/COP; reduction
in yellowing using Color
Compensation Technology (CCT)
Reduced material
consumption/cycle
time—nucleation
Fast acting new generation
nucleant for PE and PP; improved
thermal and mechanical properties
allows wall thinning; reduction of
tolerance/dimensional problems
between different colors
Laser marking
replacing ink
printing/labels
Solvent-free, high-speed
identification for Nd/YAG laser
for PE,PP, ABS, PC, POM
Antioxidants for
PE, PP, TPE
Thermal protection during
converting/downstream sterilization
Brand protection/
anticounterfeit
Covert and non-covert systems
Healthcare use limitations apply—see below.
For more detailed information on Mevopur uses and restrictions see www.avient.com/healthcare-use-limitations-mevopur-products or contact your Avient sales representative.
1.844.4AVIENT
www.avient.com
https://www.avient.com/sites/default/files/2022-12/Mevopur Healthcare Functional Additives Pharma Pkg Application Bulletin.pdf
KEY CHARACTERISTICS
• Manufactured at four ISO 13485 certified sites,
providing global consistency and increased
security of supply
• Documented change control beyond CAS
number, reducing risk of change
• Non-phthalate and formulated without animal-
derived substances
• Available for use in a wide range of polymers
including polyolefins, styrenics, polycarbonate
and alloys, polyester, POM
• Functionality can be combined with colorants
into convenient combination concentrates or
formulations
REGULATORY SUPPORT
• Pre-tested raw materials:
- ISO 10993-1 and USP biological
evaluation
- European Pharmacopeia 3.1.3/3.1.5
(polyolefin)
- USP (polyethylene)
- ICH Q3D elemental impurities
• Registered Drug Master File (Type III)
• Food contact established with FDA/EU*
APPLICATION BULLETIN
* FDA/EU compliance information available upon request
FUNCTIONALITY TARGET APPLICATIONS EBM/IBM CONTAINERS CLOSURES FILM
COMBINATION
DEVICES
Clarifying PP
Sorbitol-free—possibilities in
packaging ocular solutions
Slip/torque reduction
Slip for PE, PP films, processing aid,
torque reduction for closures
Protection from UV in
transparent packaging
for PP, PE, PETG, COP
UV blocking in 290–450nm with
no impact on clarity
Antistatic ready-to-use
solution for PE films e.g.
For more detailed information on Mevopur uses and restrictions see www.avient.com/healthcare-use-limitations-mevopur-products or contact your Avient sales representative.
1.844.4AVIENT
www.avient.com
https://www.avient.com/sites/default/files/2022-12/Mevopur Laser Marking Additives Application Bulletin.pdf
KEY CHARACTERISTICS
• Designed for Nd:YAG lasers operating between
1060-1070 nm
• Available for different polymers including
PP, PE, PC, PBT, POM, ABS, MABS
• Manufactured at four ISO 13485 certified sites,
providing global consistency and increased
security of supply
• Documented change control beyond CAS
number, reducing risk of change
• Can be designed for dark marking on natural
or white/light colored background or light
marking on black/dark background
REGULATORY SUPPORT
• Raw materials tested to:
- ISO 10993-1 and USP biological
evaluation
- European Pharmacopeia 3.1.3/3.1.5
(polyolefin)
- USP (polyethylene)
- ICH Q3D elemental impurities
• Registered Drug Master File (Type III) and/or
Device Master File
• Food contact established with FDA/EU*
APPLICATION BULLETIN
* FDA/EU compliance information available upon request.
For more detailed information on Mevopur uses and restrictions see www.avient.com/healthcare-use-limitations-mevopur-products or contact your Avient sales representative.
1.844.4AVIENT
www.avient.com
https://www.avient.com/sites/default/files/2022-12/Mevopur Colors for Ophthalmic Closures Application Bulletin_A4.pdf
KEY CHARACTERISTICS
• Manufactured at four ISO 13485 certified
manufacturing sites, providing global
consistency and increased security of supply
• Documented change control beyond CAS
number, reducing risk of change
• Non-phthalate and formulated without animal-
derived substances
• Standard concentrates in a PE carrier and
on request in PP
• Pre-colored formulations can be supplied in
specific resins selected for the application
REGULATORY SUPPORT
• Raw materials tested to:
- ISO 10993-1 and USP biological
evaluation
- European Pharmacopeia 3.1.3/3.1.5
(polyolefin)
- USP (polyethylene)
- ICH Q3D elemental impurities
• Registered Drug Master File (Type III)
• Food contact established with FDA/EU*
APPLICATION BULLETIN
DRUG TYPE COLOR DESCRIPTION
PANTONE
REFERENCE
AVIENT PRODUCT
CODE PE BASED
Adrenergic agonist
combinations
Light Green 373 C PE6M176349
Adrenergic agonists Purple 2583 C PE4M176057
Anti-infectives Tan 467 C PE8M176130
Anti-inflammatory,
nonsteroidal
Grey Cool Grey 4 C PE7M176184
Anti-inflammatory,
steroids
Pink 197 C PE3M176237
Anti-inflammatory,
immunomodulators
Olive Green 5763 C On request
Beta-blockers Yellow Yellow C PE1M176160
Beta-blocker combinations Dark Blue 281 C PE5M176272
Carbonic anhydrase inhibitors Orange 1585 C PE2M176089
Cytotoxic Black 6 C PL9M176008
Miotics Dark Green 348 C PE6M176267
Mydriatics and cycloplegics Red 1797 C PE3M176236
Prostaglandin analogues Turquoise 326 C PE5M176273
Healthcare use limitations apply—see below.
For more detailed information on Mevopur uses and restrictions see www.avient.com/healthcare-use-limitations-mevopur-products or contact your Avient sales representative.
1.844.4AVIENT
www.avient.com
https://www.avient.com/sites/default/files/2021-03/avient-antitrust-2021-update-port-a4.pdf
Linha direta de ética
https://www.Avient.com/company/policies-and-
governance/ethics-hotline
Telefone na linha direta de ética
1-877-228-5410
7
Índice Política antitruste revisada em 2021
mailto:ethics.officer%40avient.com?
subject=
http:// avient.ethicspoint.com
http://www.Avient.com/company/policies-and-governance/ethics-hotline
http://www.Avient.com/company/policies-and-governance/ethics-hotline
1.
Na primeira oportunidade que tiver, entre em contato com o Departamento Jurídico da
Avient e documente o incidente.
10
Índice Política antitruste revisada em 2021
América do Norte
Sede global Avon Lake,
Estados Unidos
33587 Walker Road Avon Lake,
OH, Estados Unidos 44012
Ligação gratuita: +1 (866) 765 9663
Telefone: +1 (440) 930 1000
Fax: +1 (440) 930 3064
Ásia-Pacífico
Sede regional Xangai, China
2F, Block C 200 Jinsu Road
Pudong, 201206 Xangai, China
Telefone: +86 (0) 21 6028 4888
Fax: +86 (0) 21 6028 4999
América do Sul
Sede regional São Paulo, Brasil
Av.
https://www.avient.com/sites/default/files/2021-03/avient-antitrust-2021-update-esp-a4.pdf
Línea Directa de Ética
https://www.Avient.com/company/policies-and-
governance/ethics-hotline
Teléfono en la Línea Directa de Ética:
1-877-228-5410
7
Índice Política Antimonopolio revisada de 2021
mailto:ethics.officer%40avient.com?
subject=
http://avient.ethicspoint.com
http://www.Avient.com/company/policies-and-governance/ethics-hotline
http://www.Avient.com/company/policies-and-governance/ethics-hotline
1.
Póngase en contacto con el Departamento Jurídico de Avient en cuanto tenga la primera
oportunidad y documente el incidente.
10
Índice Política Antimonopolio revisada de 2021
Norteamérica
Sede mundial de Avon Lake,
Estados Unidos
33587 Walker Road
Avon Lake, OH,
Estados Unidos 44012
Llamada gratuita: +1 866 765 9663
Teléfono: +1 440 930 1000
Fax: +1 440 930 3064
Asia Pacífico
Sede regional de Shanghái,
China
2F, Bloque C 200 Jinsu Road
Pudong, 201206
Shanghái, China
Teléfono: +86 (0) 21 6028 4888
Fax: +86 (0) 21 6028 4999
Sudamérica
Sede regional en São Paulo,
Brasil
Av.
https://www.avient.com/sites/default/files/2021-03/avient-antitrust-2021-update-rus-a4.pdf
Горячая линия по вопросам этики компании
https://www.Avient.com/company/policies-and-
governance/ethics-hotline
телефону
1-877-228-5410
7
Содержание Пересмотренная антимонопольная политика в 2021 г.
subject=
http://avient.ethicspoint.com
http://www.Avient.com/company/policies-and-governance/ethics-hotline
http://www.Avient.com/company/policies-and-governance/ethics-hotline
1.
Эйвон-Лейк, США
33587 Walker Road Avon Lake,
OH, United States 44012
Бесплатный тел.:
+1-866-765-9663
Телефон: +1-440-930-1000
Факс: +1-440 930 3064
Азиатско-Тихоокеанский
регион
Региональный офис в Шанхае,
Китай
2F, Block C 200 Jinsu Road
Pudong, 201206 Shanghai,
China
Телефон: +86 (0) 21 6028 4888
Факс: +86 (0) 21 6028 4999
Южная Америка
Региональный офис в
Сан-Паулу, Бразилия
Av.
https://www.avient.com/sites/default/files/2021-03/avient-antitrust-2021-update-czech-a4.pdf
Horká linka pro etiku
https://www.Avient.com/company/policies-and-
governance/ethics-hotline
telefonu
1-877-228-5410
6
Obsah Revidované antimonopolní zásady 2021
mailto:ethics.officer%40avient.com?
subject=
http://avient.ethicspoint.com
http://www.Avient.com/company/policies-and-governance/ethics-hotline
http://www.Avient.com/company/policies-and-governance/ethics-hotline
1.
Při
nejbližší příležitosti kontaktujte právní oddělení společnosti Avient a zdokumentujte incident.
9
Obsah Revidované antimonopolní zásady 2021
Severní Amerika
Globální centrála Avon Lake,
Spojené státy
33587 Walker Road Avon Lake,
OH, Spojené státy 44012
Bezplatná linka: +1-866-765-9663
Telefon: +1-440-930-1000
Fax: +440 930 3064
Asie a Tichomoří
Regionální centrála Šanghaj,
Čína
2F, Blok C 200 Jinsu Road
Pudong, 201206 Šanghaj, Čína
Telefonní číslo:
+86 (0) 21 6028 4888
Fax: +86 (0) 21 6028 4999
Jižní Amerika
Regionální centrála Sao Paulo,
Brazílie
Av.