https://www.avient.com/sites/default/files/2024-04/OnColor Orange Nylon Colorant for EV Connectors Application Bulletin.pdf
One of the critical components
inside an EV is the charging connector, which
comprises high-voltage parts that deliver power
to the vehicle’s battery.
A
cautionary orange color is often used in EVs to
distinguish high-voltage power connectors and
cables from other parts.
https://www.avient.com/sites/default/files/2023-10/Wire _ Cable Tri-fold Selection Guide_0.pdf
PRODUCT SELECTION GUIDE
WIRE & CABLE
SOLUTIONS
Specialty Engineered
Materials
High performance insulation, jacketing,
and cross-web formulations for the
wire and cable industry
Syncure™ XLPE Cross-linkable
Polyethylene Formulations
• Ambient curing
• Flame performance
• Resistant to heat, oil, creep,
& abrasion
• Low temperature properties
• Low capital investment
• High extrusion speeds
• DBDPE-free grades available
• UL/CSA bulletins
Maxxam™ FR Flame Retardant
Polyolefin Formulations
• FEP alternative
• Fire performance
• UL 444 & plenum yellow
card compliance
• Low dielectric
• High extrusion speeds
• Thin wall extrudability
Maxxam™ SY Foamable Flame
Retardant Formulations
• Low dielectric
• Uniform cell structure
• Crush & heat resistance
• Ease of chemical foaming
ECCOH™ Low Smoke and Fume
Non-Halogen Formulations
• Improved fire safety
• Low smoke, fume, non-halogen
(LSFOH) formulations
• Chemical resistance
ECCOH™ XL Cross-Linkable Solutions
• Non-halogen, low smoke, toxicity,
& corrosiveness
• Excellent mechanical & electrical
properties
• Easily processed
• Operating temperature of 90°C
• Moisture cure technology
Synprene™ Flame Retardant
Thermoplastic Elastomers
• Flexibility
• Flame performance
• Low temperature
brittleness (LTB) resistance
• Chemical resistance
• Easily colored
FireCon™ CPE Insulation Jacketing
Formulations
• Resistance to harsh environments
• Low temperature performance
• Flame performance
• High extrusion speeds
• Sunlight resistance
FEATURES SPECIFICATION
ECCOH™ XL 8148 Non-halogen, low smoke, toxicity, & corrosiveness EN50618
Syncure™ S100FH Horizontal flame UL 44
Syncure™ S100FH-XUV Horizontal flame, UV resistant UL 44
Syncure™ S100FH-UV Horizontal flame, FV-1 flame, UV resistant UL 44, UL 4703
Syncure™ S100FV VW-1 flame UL 44
Syncure™ S100FV-UV VW1, UV resistant UL 44
Syncure™ S112NA Non-flame retardant CSA 22.2
Syncure™ S120NA Non-flame retardant NSF 61
Syncure™ S200FH Horizontal flame, DBDPE-free UL 44
Syncure™ S200FV VW-1, DBDPE-free UL 44
INSULATION FOR POWER CABLE SYSTEMS
Low Voltage Power Cables
• Flame performance
• Resistance to heat, oil, creep, & abrasion
• Low temperature performance
• Low capital investment
• High extrusion speeds
INSULATION & CROSS-WEBS FOR DATA CABLE SYSTEMS
Category Cables
• FEP alternative
• Flame performance
• Low dielectric constant
• High extrusion speeds & thin wall capability
• Chemical resistance
• Low temperature performance
• Flexibility
FEATURES SPECIFICATION
Maxxam™ FR 0521-48 R1 Low smoke & fume, non-halogen UL 444
Maxxam™ FR 0587-21 R3 Halogenated to plenum performance UL 444
Optical Fiber Cables
• Resistance to harsh environments, chemicals, & sunlight
• Low temperature brittleness (LTB) resistance
• Low smoke & toxicity
• Flexibility
• High extrusion speeds
FEATURES SPECIFICATION
ECCOH™ 6649 UV Low DD Low smoke & fume, non-halogen Meets customer-specific flame requirements
Coaxial Cables
• Flexibility
• High extrusion speeds
• Low dielectric constant
• Uniform cell structure
• Crush & heat resistance
FEATURES SPECIFICATION
Maxxam™ SY 89-22-7 Foamable Meets customer-specific flame requirements
JACKETING FOR POWER & DATA CABLE SYSTEMS
Low & Medium Voltage Jacketing
• Resistance to harsh environments, chemicals, & UV degradation
• Low temperature brittleness (LTB) resistance
• Low smoke & toxicity
• Flexibility
• High extrusion speeds
• Easily colored
FEATURES SUBMARKETS & USES
FireCon™ CPE 30-33 RoHS Black Flame retardant, flexible Building & construction, industrial, nuclear
FireCon™ CPE 37-36 RoHS Black Flame retardant, flexible Building & construction, industrial, nuclear
FireCon™ CPE 30-20 RoHS Natural Flame retardant, flexible Building & construction, industrial, nuclear
ECCOH™ 5549 UV Low smoke & fume, non-halogen, flame retardant Building & construction, industrial
ECCOH™ 6649 UV Low DD Low smoke & fume, non-halogen, flame retardant Optical fiber, ducts
ECCOH™ 5981 UV Low smoke & fume, non-halogen, flame retardant Industrial, Teck 90 wire
Synprene™ RT5180 Flame retardant, LTB resistance Building & construction, industrial
Synprene™ RT5180UV Flame retardant, LTB resistance Building & construction, industrial
Synprene™ RT3870M Flame retardant, LTB resistance Building & construction, industrial
1.844.4AVIENT
www.avient.com
Copyright © 2023, Avient Corporation.
https://www.avient.com/sites/default/files/2025-03/ECCOH XL Cable Insulation Case Study Snapshot.pdf
POWER CABLE
PRODUCER
C A B L E I N S U L A T I O N
• Easy to process
• To pass CPR fire test
• Low smoke and toxicity values on smoke test
• Possibilities for low-voltage cables
• Cable insulation that passed G18 of the CEI EN 50363-0:
2015 standard
• Offered Sioplas technology for cross-linking
providing ambient curing
• Delivered new cable design possibilities for low-
voltage cables while offering easy processing
• Processed more efficiently than market-
established elastomeric technology which is
processed using a CV line
• Provided cable insulation that passes the hot set
test at 250°C
ECCOH XL Cross-Linkable Solutions 8054
KEY REQUIREMENTS
WHY AVIENT?
All Rights Reserved
https://www.avient.com/products/engineered-polymer-formulations/sustainable-formulations/eccoh-xl-cross-linkable-solutions
Power cable producer
https://www.avient.com/resources/safety-data-sheets?page=5354
MC-23785PE SNOW POLE GREEN T1232039
Together we can unlock the powerful potential of a future envisioned by you... and shared by us all.
https://www.avient.com/sites/default/files/2024-01/ECCOH 5983 - Power Cable - Case Study Snapshot.pdf
https://www.avient.com/sites/default/files/2020-10/wire-cable-1-pager.pdf
APPLICATIONS: Power cables, Ethernet category cables, industrial cables, solar installation cables, coaxial cables,
fiber optics, hybrid cables
SYNCURE™
Cross-Linked Polyethylene for Power Cable Insulation
• Resistant to heat, oil, creep and abrasion
• Fast extrusion speeds
• UL 44 & UL 4703 flame performance
• UL/CSA bulletins
MAXXAM™ FR W&C
Flame Retardant Polypropylene for Category Cable
Insulation and Cross-Webs
• Alternative to FEP
• Low dielectric
• Thin wall extrusion capabilities
• UL 444 & plenum yellow card flame performance
FIRECON™
Flame Retardant Chlorinated Polyethylene
for Industrial Cable Jackets
• Resistance to harsh environments
• Low temperature properties
• UV resistance
• UL 44 flame performance
ECCOH™ LSFOH
Low Smoke and Fume, Non-Halogen for Insulation
and Jackets
• Low smoke and toxicity
• Improved fire safety
• Resistance to chemicals
• UL44 and CPR flame performance
ADDITIONAL SOLUTIONS
MAXXAM™ SY
Foamed Polypropylene for Coaxial Cable Insulation
SYNPRENE™
Flame Retardant Thermoplastic Elastomers
POLYMIX™
Customer Proprietary Formulations
For more information, please visit avient.com
or call +1.844.4AVIENT (+1.844.428.4368).
https://www.avient.com/sites/default/files/2020-08/colormatrix-joule-tech-bulletin-a4.pdf
Such recipes
define the overall power input as well as the
lamp configuration and other important process
variables consistent with the resin and preform/
bottle design.
CAUSE AND EFFECT DIAGRAM
Methods Machines
Materials Manpower
Variable
energy
saving
during
SBM
Maintenance
instructions
Operating
instructions
Faulty
Operator
Job spec
NIR Lamps
SBM
Type/Design
vPET reheat
content
vPET
formulation
rPET
blend/quality
Temperature
recording
Temperature
measurement
probe
External
temperature
Faulty
Incomplete
Inappropriate
Incomplete
Incomplete
Different
Different
Different
Manual
Different
Variable
Variable
Variable
Training
New
Faulty
Alignment
Same
Throughput
Too many tasks
Time conflict
Age/intensity
variable
Set up conditions
Configuration
- When starting to process a new resin, first
run through new preforms for 15 minutes at
‘standard’ conditions to establish steady state
conditions prior to any process optimization
- Slowly start to reduce preform blowing
temperatures until failures are present
(visible pearl internal wall or pearl feet)
- Increase blowing temperatures until defects
are eliminated
- QC check bottle quality for acceptance versus
established tolerances
- Change the power consumption profile in the
ovens for early heat and longer sink times but
ensure overall temperatures do not exceed cold
crystallization temperature
- Repeat temperature reduction stage and
then defect elimination stage to test if further
optimization is possible
- Recheck QC bottle quality for acceptance versus
established tolerances
- Log all process parameters and create new
specific ‘recipe’ for future use
www.avient.com
Copyright © 2020, Avient Corporation.
https://www.avient.com/sites/default/files/2021-12/certificate-of-registration-avient-s.a-r.l.-sweden-filial-nov-29-2021.pdf
Sweden Filial
Address:
Drottninggatan 56
411 07 GÖTEBORG
County and municipality: Västra Götaland, Göteborg
Note:
MANAGING DIRECTOR
630516 Palm, Christoph, Gruss Strooss 35, L-9991 WEISWAMPACH,
LUXEMBURG
AUDITORS
556053-5873 Ernst & Young Aktiebolag, Box 7850, 103 99 STOCKHOLM
Represented by: 850807-5135
PRINCIPALLY RESPONSIBLE AUDITOR
850807-5135 Edman, Mikael Thomas Gunnar, c/o Ernst & Young AB,
401 82 GÖTEBORG
SIGNATORY POWER
Signatory power alone by
Palm, Christoph
FINANCIAL YEAR
Registered financial year: 0101 - 1231
DATE OF REGISTRATION OF CURRENT AND PREVIOUS BUSINESS NAMES
2021-11-29 Avient S.à r.l., Sweden Filial
2018-08-28 PolyOne S.à.r.l., Sweden Filial
INFORMATION ABOUT THE FOREIGN COMPANY
B226205
Avient S.á.r.l.
19, Route de Bastogne
L-9638 Pommerloch
LUXEMBURG
Registered office of the foreign company:
Pommerloch
Name of the register in which the foreign company is registered:
e-Certificate of registration
Swedish Companies Registration Office
BRANCH
D1a- 6858922
Registration number
Date of registration of the company
Document created on
Date of registration of current name
Page
516411-5031
2018-08-28
2021-11-30 17:11
2021-11-29
3 (3)
RCS, Registre de Commerce,
Luxembourg Business Register
LUXEMBURG
Foreign company's financial year:
0101 - 1231
The above information is an extract from the Trade and Industry
Register Bolagsverket, the Swedish Companies Registration Office.
https://www.avient.com/sites/default/files/2023-01/Versaflex OM -Diastimeter Cover-Application Snapshot.pdf
POWER TOOL
BRAND
D I A S T I M E T E R C O V E R
• Anti-static properties to enable stable and accurate
measurements
• Good wear resistance to avoid friction between TPE-made
part and the internal metal part
• Met anti-static standard surface resistivity
109-1010 Ω/m2 which reduced error for
circular measurement by 55% and linear
measurement by 33%
• Provided a formulation with better wear
resistance than the previous overmold
material
• Offered excellent bond adhesion to PC/ABS
Versaflex ™ OM Thermoplastic Elastomer
KEY REQUIREMENTS
WHY AVIENT?
https://www.avient.com/sites/default/files/2021-01/wire-and-cable-one-pager.pdf
APPLICATIONS: Power cables, Ethernet category cables, industrial cables, solar installation cables, coaxial cables,
fiber optics, hybrid cables
SYNCURE™
Cross-Linked Polyethylene for Power Cable Insulation
• Resistant to heat, oil, creep and abrasion
• Fast extrusion speeds
• UL 44 & UL 4703 flame performance
• UL/CSA bulletins
MAXXAM™ FR W&C
Flame Retardant Polypropylene for Category Cable
Insulation and Cross-Webs
• Alternative to FEP
• Low dielectric
• Thin wall extrusion capabilities
• UL 94 & plenum yellow card, V-2, V-0 & 5VA
fire performance ratings
FIRECON™
Flame Retardant Chlorinated Polyethylene
for Industrial Cable Jackets
• Resistance to harsh environments
• Low temperature properties
• UV resistance
• UL 44 flame performance
ECCOH™ LSFOH
Low Smoke and Fume, Non-Halogen for Insulation
and Jackets
• Low smoke and toxicity
• Improved fire safety
• Resistance to chemicals
• UL44 and CPR flame performance
ADDITIONAL SOLUTIONS
MAXXAM™ SY
Foamed Polypropylene for Coaxial Cable Insulation
SYNPRENE™
Flame Retardant Thermoplastic Elastomers
POLYMIX™
Customer Proprietary Formulations
For more information, please visit avient.com
or call +1.844.4AVIENT (+1.844.428.4368).