https://www.avient.com/sites/default/files/2022-06/Avient PCR Color Prediction Tool Solution Bulletin.pdf
Convertors and brand owners need to make
educated choices for their recycled materials based
on formulation expertise and data science to help
achieve a consistent packaging product.
Based on color science, the tool helps optimize
the ratio of virgin resin to PCR in order to achieve
the best acceptable rendering, proven by scientific
data.
https://www.avient.com/sites/default/files/2021-06/fl.datasheet-frp.pdf
FRP FIBERS PROCESSES PRODUCTS
MOVING HIGH PERFORMANCE FIBERS FORWARD
This data is provided for informational purposes only, and does not constitute a specification.
Uranusweg 3
8938 AJ Leeuwarden
The Netherlands
+31(0) 58 216 75 99
info@fiber-line.com
ABOUT FIBER-LINE®
NOTICE: The information and data contained herein do not constitute sales specifications.
https://www.avient.com/sites/default/files/2021-06/fl.datasheet-kevlarr-distribution-program.pdf
KEVLAR® DISTRIBUTION PROGRAM FIBERS PROCESSES PRODUCTS
MOVING HIGH PERFORMANCE FIBERS FORWARD
This data is provided for informational purposes only, and does not constitute a specification.
°C 425-480
KEVLAR® PARA-ARAMID (HM) BARE FIBER PERFORMANCE
KEVLAR® PARA-ARAMID DATA
Standard Modulus High Modulus
* Equilibrium moisture regain @ 55% RH ** Creep @ 40%-58% ultimate tensile strength *** Shrinkage in dry air @ 177 C for 30 minutes
CHEMICAL COMPATIBILITY
Chemical Resistance to Acid: Degrades in Formic, Hydrochloric, and Sodium Hydroxide acid.
Uranusweg 3
8938 AJ Leeuwarden
The Netherlands
+31(0) 58 216 75 99
info@fiber-line.com
ABOUT FIBER-LINE®
NOTICE: The information and data contained herein do not constitute sales specifications.
https://www.avient.com/sites/default/files/2021-06/fl.us-.datasheet-carbon-fiber.pdf
MOVING HIGH PERFORMANCE FIBERS FORWARD
CARBON FIBER
CARBON FIBER DATA
Standard Modulus
Property UOM Value
Breaking Tenacity g/d 23.0
Specific Gravity Ratio 1.80
Elongation @ Break % 1.5
Tensile Modulus g/d 1480
Moisture Regain* % 0
Creep** % 0
Shrinkage*** % 0
Melt Point °C None
Decomposition Temp.
°C Various
Abrasion
Resistance
Yarn on Yarn
Abrasion
Ultraviolet (UV)
Resistance
Flame
Resistance
Chemical
Resistance
(Acid)
Chemical
Resistance
(Alkali)
Chemical
Resistance
(Organic Solvent)
O X P P P P P
This data is provided for informational purposes only, and does not constitute a specification.
Uranusweg 3
8938 AJ Leeuwarden
The Netherlands
+31(0) 58 216 75 99
info@fiber-line.com
ABOUT FIBER-LINE®
NOTICE: The information and data contained herein do not constitute sales specifications.
https://www.avient.com/sites/default/files/2021-06/fl.a4.datasheet-technora.pdf
TECHNORA® FIBERS PROCESSES PRODUCTS
MOVING HIGH PERFORMANCE FIBERS FORWARD
This data is provided for informational purposes only, and does not constitute a specification.
TECHNORA®
TECHNORA® DATA
Standard Modulus
* Equilibrium moisture regain @ 55% RH ** Creep @ 40%-58% ultimate tensile strength *** Shrinkage in dry air @ 177 C for 30 minutes
MOVING HIGH PERFORMANCE FIBERS FORWARD
LOCATIONS
Headquarters, R&D, Manufacturing
FIBER-LINE® LLC
3050 Campus Drive
Hatfield, PA 19440
+1 215.997.9181
fiber@fiber-line.com
Manufacturing Operations
FIBER-LINE® LLC
280 Performance Drive SE
Hickory, NC 28602
+1 828.326.8700
fiber@fiber-line.com
EMEA & Asia Pacific Operations
FIBER-LINE® INTERNATIONAL B.V.
Uranusweg 3
8938 AJ Leeuwarden
The Netherlands
+31(0) 58 216 75 99
info@fiber-line.com
NOTICE: The information and data contained herein do not constitute sales specifications.
https://www.avient.com/sites/default/files/2021-06/fl.us-.datasheet-uhmwpe.pdf
°C TBD
Standard Tenacity High Tenacity
MOVING HIGH PERFORMANCE FIBERS FORWARD
This data is provided for informational purposes only, and does not constitute a specification.
UHMWPE DATA
UHMWPE BARE FIBER PERFORMANCE
* Equilibrium moisture regain @ 55% RH ** Creep @ 40%-58% ultimate tensile strength *** Shrinkage in dry air @ 177 C for 30 minutes
MOVING HIGH PERFORMANCE FIBERS FORWARD
ABOUT FIBER-LINE®
LOCATIONS
Headquarters, R&D, Manufacturing
FIBER-LINE® LLC
3050 Campus Drive
Hatfield, PA 19440
+1 215.997.9181
fiber@fiber-line.com
Manufacturing Operations
FIBER-LINE® LLC
280 Performance Drive SE
Hickory, NC 28602
+1 828.326.8700
fiber@fiber-line.com
EMEA & Asia Pacific Operations
FIBER-LINE® INTERNATIONAL B.V.
Uranusweg 3
8938 AJ Leeuwarden
The Netherlands
+31(0) 58 216 75 99
info@fiber-line.com
NOTICE: The information and data contained herein do not constitute sales specifications.
https://www.avient.com/sites/default/files/2020-08/colormatrix-flexcart-melt-injection-metering-system-flyer-1.pdf
Are data management facilities needed?
VALUE BENEFITS OF USING THE
FLEXCART SYSTEM
FlexCart & PlanetPak components create a market leading
metering technology:
• Robust and reliable system control
• Reliable yield (99%) and sustainable packaging
• Capability of data networking and remote
internet support
• Reduced changeover cost with interchangeable cassettes
FLEXCART™
MELT INJECTION LIQUID
METERING SYSTEM
Combined with the PlanetPak™
delivery packaging
ATTRIBUTE FLEXCART M.I.
ATTRIBUTE PC PUMP
CMG
6000
Metering throughput High –
Volumetric/gravimetric V V/G
Data export/network – Yes
Touch screen – Yes
Multiple log-in levels – Yes
Multiple log-in levels – No
www.avient.com
Copyright © 2020, Avient Corporation.
https://www.avient.com/sites/default/files/2020-08/colormatrix-flexcart-mini-liquid-metering-system-flyer-1.pdf
Are data management facilities needed?
VALUE BENEFITS OF USING THE
FLEXCART MINI SYSTEM
FlexCart units & PlanetPak containers create
a market leading metering system:
• Robust and dependable system control
• Reliable yield (typically 99% using a PlanetPak)
and sustainable packaging
• Capability of data networking and remote
internet support
• Simplified changeover with interchangeable
cassettes
FLEXCART™
MINI LIQUID
METERING SYSTEM
Combined with the PlanetPak™
delivery packaging
Note: PC = Progressing Cavity Pump
Peri = Peristatic Pump
ATTRIBUTE FLEXCART MINI
Footprint (LxW cm) 98 x 38
Controller options
3000
5000
Typical max.
ATTRIBUTE PC PUMP
PERI
PUMP
CMG
3000
CMG
5000
Delivery throughput – Low – –
Metering throughput High Low – –
Volumetric/gravimetric V V V V/G
Data export/network – – No Yes
Touch screen – – No Yes
Multiple log-in levels – – No Yes
The range of progressing
cavity pump rates attainable
can be used to determine
the correct size of pump.
https://www.avient.com/sites/default/files/resources/TPE_Overmolding_Solutions_for_Engineering_Thermoplastics.pdf
The other commercially available TPE’s
were processed as per the recommendations made in their respective data
sheets.
Data is reported in pounds
per linear inch (pli).
Set 22hr. @ 70 C 88 85 86 85 85 91 73
Table 2: Adhesion data of developed products in pli units.
https://www.avient.com/sites/default/files/2024-12/Terms and Conditions of Sale for Austria.pdf
Data Protection.
Seller is entitled to process the personal data
entrusted to it within the scope of the purpose of the contractual
relationship and in compliance with the provisions of the Data
Protection Act.
Buyer consents to the transfer of its data, entrusted
to the Seller, to Avient in the USA for purposes related to the
contractual relationship.
25.