https://www.avient.com/sites/default/files/2025-08/Advanced Composites in Building _ Construction Application Guide.pdf
MATERIAL SOLUTION DESCRIPTION KEY CHARACTERISTICS POTENTIAL APPLICATIONS Hammerhead™ FR Flame Retardant Composite Panels Industry-first flame retardant thermoplastic composite panels that meet ASTM E84 Class A standards for flame spread and smoke developed and configurations available to meet NFPA 286 corner room burn testing • Excellent flame performance • Moisture, UV, corrosion, impact, and rot resistant • Lightweight structural integrity • Reduce labor cost and time • Interior Wall, Floor & Ceiling Panel Systems • Garage Doors • Interior & Entry Doors • Exterior Sheathing • Siding & Cladding • Kitchen Cabinetry Hammerhead™ and Polystrand™ Composite Panels Thermoplastic composite panels constructed with Polystrand™ continuous fiber laminates thermally bonded to thermoplastic foam or honeycomb cores • Moisture, UV, corrosion, impact, and rot resistant • Lightweight structural integrity • Reduce labor cost and time • Garage Doors • Interior Entry Doors • Interior Wall, Floor & Ceiling Panel Systems • Exterior Sheathing • Siding & Cladding • Kitchen Cabinetry Polystrand™ Continuous Fiber Tapes & Laminates High strength unidirectional (UD) glass fibers combined with thermoplastic resins available in unidirectional tapes or multi-ply laminates • High strength and stiffness • Enables impact resistance • Formulations available to meet ASTM E84 Class A and Class B flame/smoke rating • Composite Deckng • Interior & Entry Doors • Roofing Systems GlasArmor™ Ballistic Resistant Panels Ballistic protection constructed from layers of 0°/90° woven E-glass fiber reinforcements with a proprietary thermoset resin system • UL 752 Level 1–3 compliant • Less than 25% the weight of comparable steel panel • 1-hr fire rating per ASTM E119* • Safe/Panic Rooms • Garage Doors • Interior & Entry Doors ThermoBallistic™ Thermoplastic Panels Industry-first thermoplastic ballistic resistant panels thermally formed with layers of 0°/90° UD E-glass fiber reinforcements and polyolefin-based resin systems • UL 752 Level 3 compliant • Extremely lightweight • Moisture, UV, and corrosion resistant • Safe/Panic Rooms • Garage Doors • Interior & Entry Doors * UL Level 3 panel was fire tested as part of a wall system with steel studs and drywall facesheet
https://www.avient.com/sites/default/files/resources/TPE_Overmolding_Solutions_for_Engineering_Thermoplastics.pdf
The mold is then opened and the core plate is rotated and the second material is injected from the secondary rubber system.
If the part requires the use of thick sections, they should be cored out to minimize shrinkage problems and to reduce the part weight and cycle time.
Properly designed deep undercuts however are possible with GLS over-mold compounds if an advancing core is used when the mold opens and the part does not have sharp corners and the elastomer is allowed to deflect as it is ejected.
https://www.avient.com/sites/default/files/2020-08/maxxam-polyolefins-formualtions-case-study.pdf
As a core part of the HVAC system, the door flap is situated close to a set of brush motors, which are packed with copper wires.
https://www.avient.com/sites/default/files/2020-09/bettcher-case-study-1.pdf
THE IMPACT At its core, the goal of re-engineering the motor yoke was to maintain quality, durability and strength while reducing weight and lowering costs.
https://www.avient.com/sites/default/files/2021-12/MagIQ Nonwoven Electret for HEPA Application Bulletin.pdf
The core parts of filter media are engineered structures produced from PP meltblown nonwoven material.
https://www.avient.com/sites/default/files/2024-11/Ballistic Panel Infographic.pdf
Shots Composite Panel Nominal Thickness Nominal Weight Level 1 9mm full metal copper jacket with lead core 1175 ft/sec 358 m/sec 3 GlasArmor™ Level 1 0.256 in 6.5 mm 2.7 lb/ft2 13.2 kg/m2 Level 2 .357 magnum jacketed head soft point 1250 ft/sec 381 m/sec 3 GlasArmor™ Level 2 0.384 in 9.8 mm 4.0 lb/ft2 19.5 kg/m2 Level 3 .44 magnum lead semi-wadcutter gas checked 1350 ft/sec 411 m/sec 3 GlasArmor™ Level 3 0.500 in 12.7 mm 5.2 lb/ft2 26.4 kg/m2 ThermoBallistic™ Level 3 0.440 in 11.2 mm 3.9 lb/ft2 19.0 kg/m2 PR OT EC TI O N L EV EL S Level 4–8: Customized solutions available, contact Avient to learn more.
https://www.avient.com/investor-center/news/polyone-announces-appointment-woon-keat-moh-vice-president-asia
Guided by its Core Values, Sustainability Promise and No Surprises PledgeSM,
https://www.avient.com/investor-center/news/polyone-announces-promotion-robert-t-bindner-president-performance-products-solutions
Guided by its Core Values, Sustainability Promise and No Surprises PledgeSM,
https://www.avient.com/investor-center/news/polyone-appoints-walter-ripple-vice-president-sustainability-joins-alliance-end-plastic-waste-founding-member
Guided by its Core Values, Sustainability Promise and No Surprises PledgeSM,
https://www.avient.com/investor-center/news/polyone-board-directors-appoints-robert-m-patterson-chairman-board
Guided by its Core Values, Sustainability Promise and No Surprises PledgeSM,