https://www.avient.com/resources-0?document_type=59&document_subtype=0&industry=0&product_family=0&product_name=0&op=FILTER RESULTS&form_id=resource_filter_form&page=4
Colorant Chromatics™ Metallic Effect Pre-colored Sulfone Colorants provided a non-conductive solution with reduced VOCs and coexisting color and metallic effects
Stat-Tech™ Static Dissipative & Electrically Conduction formulations provided flame retardant and anti-static solution for vacuum cleaner handle
https://www.avient.com/resources-0?document_type=59&document_subtype=0&industry=0&product_family=0&product_name=0&op=FILTER RESULTS&form_id=resource_filter_form&page=5
Colorant Chromatics™ Conductive Formulations provided tailored solutions for specific conductivity requirements
https://www.avient.com/resources-0?document_type=59&document_subtype=0&industry=0&product_family=0&product_name=0&op=FILTER RESULTS&form_id=resource_filter_form&page=41
Stat-Tech™ Static Dissipative and Electrically Conductive Formulations
Injection molding parameters, startup and shutdown, mold design and troubleshooting recommendations for Stat-Tech™ Static Dissipative and Conductive Formulations
https://www.avient.com/sitemap
Code of Conduct
Therma-Tech™ Thermally Conductive Formulations
Silcosperse™ TC Thermally Conductive Dispersions
https://www.avient.com/sites/default/files/2023-10/LubriOne Product Selection Guide.pdf
Steel – Static 0.25 0.46 0.18 0.15 0.12 0.19 0.11 0.14 0.13 0.24 0.17 0.17 Impact Notched Izod Impact (23°C, 3.18 mm, Injection Molded) J/m ASTM D256A 41 64(6) 110 107 107 70 80 37 37 75 – 69 Thermal Properties Heat Deflection Temperature ASTM D648 0.45 MPa °C 215(6) – 250 215 216 184 152 151(6) 153(6) 218(6) – – 1.8 MPa °C 65(6) 239(7) 244(6) 210 210 75 94 81.1(6) 88 197(6) – 135(5) Electrical Properties Surface Resistivity ohms/sq ASTM D254 – – – 1.30x1012 1.9x1012 5.2x1012 – – – – – 1.0x109 Dielectric Strength (Short Time) kV/mm – – 8.5 – – – – – – – – – Flammability Flame Rating Class UL 94 HB – – HB HB HB – HB – – – – LubriOne™ Internally Lubricated Formulations NOTES (1) Type I, 5.1mm/min (2) Type I, 21.3 mm/min (3) Type I, 50 mm/min (4) Type I, 5.1mm/min, Break (5) 3.2 mm thick, Unannealed (6) 6.35 mm thick, Unannealed (7) 3.2 mm thick, Annealed PRODUCT DESCRIPTION UNITS TEST METHOD LB6000- 5024 RS HI Natural LB6000- 5021 RS S1 Black LB6000- 5021 RS X2 Black LB6000- 5019 X1 Black LB6700- 5001 RS AF Black NN- 000/01M Black SO REC LB6600- 5030 RS Grey LB3300- 5010 RS Natural LB3300- 5005 RS Natural REC LB3220- 5001 RS C Natural X1 LB8900- 5010 GP Grey LB8900- 5006 RS PE Natural LB8900- 5004 RS PE Natural LB4200- 5022 Black LB4200- 5023 Natural Base Polymer PA 6 PA6/PA66 PA66 PBT PC PKE POM Lubricant UHMWPE1 UHMWPE UHMWPE UHMWPE UHMWPE MoS22 Graphite UHMWPE UHMWPE UHMWPE Graphite UHMWPE UHMWPE MoS2 UHMWPE Filler type GF10 GF30 GF30 GF50 GF50 Unfilled GF33 GF20 MI20 GF10 Unfilled GF20 GF30 Unfilled Unfilled General Properties Specific Gravity g/cm3 ISO 1183 1.18 1.35 1.39 1.55 1.58 1.14 1.44 1.42 1.46 1.23 1.26 1.34 1.43 1.4 1.35 Mechanical Properties Tensile Modulus (23°C) MPa ISO 527-1 4250 9500 9000 15500 16600 3500 10600 6300 3330 4000 1630 5300 9250 2470 2150 Tensile Strength (Yield, 23°C) MPa ISO-527-2 97 150 160 205 200 85 164 102 55 60 60 108 99.1 55 50 Tensile Elongation (Break, 23°C) % ISO-527-2 12 2.5 3 2.7 2.4 3.4 2.0 4.2 8 2.5 46 3.7 1.5 11 11 Flexural Strength (23°C) MPa ISO 178 103 – – 285 265 108 215 127 78 85 38 155 117 73 68 Flexural Modulus (23°C) MPa ISO 178 3250 – – 12400 11100 2690 9000 4700 3000 3100 1380 4600 5450 2210 2070 Impact Charpy Notched Impact Strength (23°C, Injection Molded) kJ/m^2 ISO 179 14 12 10 15 10 3 6 7.7 4.3 12 15 10 7.6 8 5 Charpy Unnotched Impact Strength (23°C, Injection Molded) kJ/m^2 ISO 179 82 55 61 75 60 65 50 47 69 - NB 63 36 NB NB Thermal Properties Deflection Temperature Under Load 1.8 Mpa, Unannealed °C ISO 75-2/A 107 – – 204 – 73 235 – – – 90 210 204 86 80 Cofficient of Friction (CoF) & Wear Rate CoF vs.
You have the responsibility to conduct full-scale end-product performance testing to determine suitability in your application, and you assume all risk and liability arising from your use of the information and/or use or handling of any product.
https://www.avient.com/knowledge-base/article/protecting-polymers-microbe-growth?ind[]=21537
To better evaluate how to protect plastic parts from microbial attack, Avient conducted a study to screen a variety of plastic substrates for susceptibility using American Society for Testing and Materials (ASTM) G21 (fungi susceptibility), Japanese Industrial Standard (JIS) Z2801, and modified ASTM E1428-15a (bacterial susceptibility) test standards.
https://www.avient.com/knowledge-base/article/protecting-polymers-microbe-growth?rtype[]=1164
To better evaluate how to protect plastic parts from microbial attack, Avient conducted a study to screen a variety of plastic substrates for susceptibility using American Society for Testing and Materials (ASTM) G21 (fungi susceptibility), Japanese Industrial Standard (JIS) Z2801, and modified ASTM E1428-15a (bacterial susceptibility) test standards.
https://www.avient.com/knowledge-base/article/understanding-tpe-material-and-performance-enabling-5g-technologies?rtype[]=1164
While rigid polymers are typically used for this because of their conductive and wireless properties, Avient has found additional value in low signal loss technology within its thermoplastic elastomer (TPE) portfolio.
https://www.avient.com/knowledge-base/article/understanding-tpe-material-and-performance-enabling-5g-technologies?ind[]=21508
While rigid polymers are typically used for this because of their conductive and wireless properties, Avient has found additional value in low signal loss technology within its thermoplastic elastomer (TPE) portfolio.
https://www.avient.com/knowledge-base/article/protecting-polymers-microbe-growth
To better evaluate how to protect plastic parts from microbial attack, Avient conducted a study to screen a variety of plastic substrates for susceptibility using American Society for Testing and Materials (ASTM) G21 (fungi susceptibility), Japanese Industrial Standard (JIS) Z2801, and modified ASTM E1428-15a (bacterial susceptibility) test standards.