https://www.avient.com/sites/default/files/2022-08/Schedule 2 a_b_c - SCCs_0.pdf
The data importer shall immediately inform the data exporter if it is unable to follow those instructions. 8.2 Purpose limitation The data importer shall process the personal data only for the specific purpose(s) of the transfer, as set out in Annex I.B, unless on further instructions from the data exporter. 8.3 Transparency On request, the data exporter shall make a copy of these Clauses, including the Appendix as completed by the Parties, available to the data subject free of charge.
Any onward transfer is subject to compliance by the data importer with all the other safeguards under these Clauses, in particular purpose limitation. 8.9 Documentation and compliance a.
Any onward transfer is subject to compliance by the data importer with all the other safeguards under these Clauses, in particular purpose limitation. 8.9 Documentation and compliance a.
https://www.avient.com/sites/default/files/2025-04/Supplier Code of Conduct FV_Port.pdf
A nossa posição única na cadeia de abastecimento permite-nos trabalhar com os fornecedores para inovar em soluções de materiais que ajudem os nossos clientes a ter sucesso, permitindo simultaneamente um Reconhecemos que a nossa responsabilidade se estende para além dos nossos limites operacionais e de processo, abrangendo os nossos parceiros fornecedores.
https://www.avient.com/sites/default/files/2020-12/maxxam-fr-case-study.pdf
AN ALTERNATIVE FLAME RETARDANT SOLUTION FOR CATEGORY CABLES CASE STUDY: MAXXAM™ FR POLYPROPYLENE Challe nge Accepted.
THE SOLUTION The manufacturer worked with Avient to identify alternatives to FEP insulation that would meet requirements in their data cable.
https://www.avient.com/sites/default/files/2025-07/ISO IEC 17025 Chemical Avon Lake.pdf
No. 0514.02) 12/11/2023 Page 1 of 1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 AVIENT CORPORATION – ANALYTICAL SOLUTIONS 33587 Walker Road Avon Lake, OH 44012 Stephanie Mims Phone: 440-930-3499 CHEMICAL Valid To: September 30, 2025 Certificate Number: 0514.02 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following rubber and plastics tests: Test Description: Test Method or Standard: FTIR (Fourier Transform Infrared) Spectroscopy ASTM E1252 (Except 7.6, 11.2, and 11.4) Flammability Horizontal Burn of Self-Supporting Plastics ASTM D635; UL 94; IEC 60695-11-10 Horizontal Burn of Materials Used in Occupant Compartments of Motor Vehicles ASTM D5132; FMVSS 302 (49 CFR 571.302); ISO 3785 Vertical Burn, 20 mm ASTM D3801; UL 94; IEC 60695-11-10 Vertical Burn, 125 mm ASTM D5048; UL 94; IEC 60695-11-20 Thin Material Burning Test UL-94 Glow Wire Test IEC 60695 2-10, 2-11, 2-12, 2-13 Thermal Analysis DSC (Differential Scanning Calorimetry) ASTM D3418, E794, E1356 TGA (Thermogravimetric Analysis) ASTM E1131 TMA (Linear Thermal Expansion of Solid Materials by Thermomechanical Analysis) ASTM E831; ISO 11359-2 Karl Fischer Moisture Content ASTM D6869 For the tests to which this accreditation applies, please refer to the laboratory’s Chemical Scope of Accreditation.
Accredited Laboratory A2LA has accredited AVIENT CORPORATION – ANALYTICAL SOLUTIONS Avon Lake, OH for technical competence in the field of Chemical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories.
https://www.avient.com/sites/default/files/2025-07/ISO IEC 17025 Mechanical Avon Lake.pdf
No. 0514.01) 12/11/2023 Page 1 of 1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 AVIENT CORPORATION – ANALYTICAL SOLUTIONS 33587 Walker Road Avon Lake, OH 44012 Stephanie Mims Phone: 440 930 3499 MECHANICAL Valid To: September 30, 2025 Certificate Number: 0514.01 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following rubber and plastics tests: Test Description Test Method or Standard Brittleness Temperature (Impact) ASTM D746; ISO 812 Charpy Impact ISO 179-1 Color Determination by Spectrophotometer ASTM D2244, E1331; ISO 7724 Conditioning of Plastics for Testing ASTM D618; ISO 291 Deflection Temperature Under Flexural Load ASTM D648; ISO 75-1, -2 Durometer Hardness (Shore A and D) ASTM D2240; ISO 7619-1 Flexural Properties ASTM D790; ISO 178 Flow Rate (Extrusion Plastometer) ASTM D1238 (Procedures A and B); ISO 1133 Impact Resistance (Izod) ASTM D256; ISO 180 Instrumented Impact ASTM D3763; ISO 6603-2 Specific Gravity/Density ASTM D792 (Method A); ISO 1183-1 Specular Gloss ASTM D523; ISO 2813 Tackiness of Interior Materials BO 061-01 Tear Resistance ASTM D624, D1004; ISO 34 Tensile Properties ASTM D412 (Method A), D638, D882; ISO 37, 527-1, -2, -3, -4, -5 Xenon-Arc Exposure Testing ASTM D2565, G155; SAE J1885 (Withdrawn January 2008), J1960 (Withdrawn January 2008), J2412, J2527; BO-116-01 For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation.
Accredited Laboratory A2LA has accredited AVIENT CORPORATION – ANALYTICAL SOLUTIONS Avon Lake, OH for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories.
https://www.avient.com/sites/default/files/2023-03/Therma-Tech Heat Sink for Auto Lights Case Study.pdf
THE SOLUTION Avient worked with Elausa to develop a thermoplastic solution to suit their requirements and Therma-Tech™ Thermally Conductive Formulations were chosen as a potential fit.
https://www.avient.com/sites/default/files/2024-11/Edwards Ballistic Panel Case Study.pdf
THE SOLUTION This coordinated effort resulted in the innovative Modular Protective System (MPS) portable structure, which incorporates an Edwards-designed collapsible truss framework and Avient’s GlasArmor™ ballistic resistant composite panels.
With our hardware fabrication capabilities and Avient’s knowledge of composite ballistic protection technology, we were able to create modular systems that reduce time and logistic requirements for our brave soldiers.” 1 https://www.erdc.usace.army.mil/Missions/Military-Engineering/Deployable-Force-Protection-Demo/ To learn more about ballistic resistant solutions from Avient, visit avient.com or click to request a quote.
https://www.avient.com/sites/default/files/2020-09/hiviz-recoil-pad-case-study.pdf
THE SOLUTION HIVIZ had several years of experience working with Avient materials for shotgun sights.
CUSTOM RECOIL PAD MATERIALS DELIVER SUPERIOR RECOIL REDUCTION AND EXCEPTIONAL DURABILITY TO A HIGH-END RIFLE MANUFACTURER To learn more about customizable TPE solutions, contact Avient at +1.844.4AVIENT (1.844.428.4368) or visit www.avient.com. © 2020, All Rights Reserved Avient Corporation, 33587 Walker Road, Avon Lake, Ohio USA 44012
https://www.avient.com/sites/default/files/2023-05/case-study-piranha-propeller.pdf
THE SOLUTION Avient proactively worked with Piranha to develop the next generation propeller.
Complēt™ MT long glass fiber reinforced nylon 6 composite was selected because of the extra durability provided, making this solution ideal for demanding applications like Piranha’s propellers.
https://www.avient.com/sites/default/files/2020-08/trilliant-case-study-1.pdf
THE SOLUTION The manufacturer approached Avient with its challenge.
Since chemical resistance was one of the most important requirements for this solution, stress tests involving disinfectants were used to filter initial options.