https://www.avient.com/sites/default/files/2020-09/lubrione-processing-guide.pdf
BASE
RESIN
PPA PC PSU PES PPS
CO-
POLYMER
ACETAL
PEEK PA
Barrel Temperatures* °F (°C)
Rear Zone
550–580
(288–305)
520–560
(271–293)
600–640
(316–338)
630–660
(332–338)
550–580
(288–304)
350–370
(177–188)
660–700
(349–371)
440–490
(227–254)
Center Zone
560–600
(293–316)
530–570
(277–299)
620–670
(327–354)
650–680
(343–360)
560–615
(293–324)
380–390
(193–200)
700–730
(371–388)
470–510
(243–266)
Front Zone
580–620
(304–327)
550–580
(288–305)
630–680
(332–360)
670–730
(354–388)
590–630
(310–332)
390–430
(200–221)
720–750
(382–400)
490–540
(254–282)
Nozzle
575–615
(302–324)
550–600
(288–316)
630–680
(332–360)
680–700
(360–371)
600–625
(316–330)
380–415
(193–213)
720–750
(382–400)
520–570
(271–300)
Melt
Temperature
575–615
(302–324)
560–600
(293–316)
625–675
(330–358)
650–710
(343–377)
600–625
(316–330)
370–410
(188–210)
670–740
(354–393)
520–570
(271–300)
Mold
Temperature
250–300
(121–150)
175–240
(80–116)
190–300
(88–150)
225–325
(107–164)
250–325
(121–164)
150–225
(66–107)
290–375
(143–190)
150–200
(66–93)
Pack & Hold
Pressure
50%–75%
of Injection Pressure
Injection
Velocity
in/s
1.0–3.0
Back Pressure
psi
50
Screw Speed
rpm
50–90
Drying
Parameters
°F (°C)
6 hrs @ 175
(80)
4 hrs @ 250
(121)
4 hrs @ 275
(135)
4 hrs @ 300
(150)
4 hrs @ 250
(121)
2 hrs @ 200
(93)
3 hrs @ 300
(150)
4 hrs @ 180
(82)
Allowable
Moisture
%
< 0.05 < 0.02 < 0.02 < 0.04 < 0.02 0.15–0.20 < 0.02 0.10–0.20
Cushion
in
0.125–0.250
Screw
Compression
Ratio
2.5:1–3.5:1 2.0:1–2.5:1 2.5:1–3.5:1 2.5:1–3.5:1 2.5:1–3.5:1 2.5:1–3.5:1 2.5:1–3.5:1 2.5:1–3.5:1
Nozzle
Type
General
Purpose
General
Purpose
General
Purpose
General
Purpose
General
Purpose
General
Purpose
General
Purpose
Reverse
Taper
Clamp
Pressure
5–6 Tons/in2 of projected area of cavities and runner system
* Barrel temperatures should be elevated for compounds designed for electrical insulative properties.
Draft Angle • Maintain a minimum draft angle of 1/2° per side.
https://www.avient.com/sites/default/files/2020-09/edgetek-processing-guide.pdf
Base Resin PPA PC PSU PES PPS
Co-
polymer
Acetal
PEEK PA
Barrel Temperatures* °F (°C)
Rear Zone
550–580
(288–305)
550–590
(288–310)
600–640
(316–338)
630–660
(332–338)
550–580
(288–304)
350–370
(177–188)
660–700
(349–371)
440–490
(227–254)
Center Zone
560–600
(293–316)
570–600
(300–316)
620–670
(327–354)
650–680
(343–360)
560–615
(293–324)
380–390
(193–200)
700–730
(371–388)
470–510
(243–266)
Front Zone
580–620
(304–327)
580–630
(304–322)
630–680
(332–360)
670–730
(354–388)
590–630
(310–332)
390–430
(200–221)
720–750
(382–400)
490–540
(254–282)
Nozzle
575–615
(302–324)
580–630
(304–322)
630–680
(332–360)
680–700
(360–371)
600–625
(316–330)
380–415
(193–213)
720–750
(382–400)
520–570
(271–300)
Melt
Temperature
575–615
(302–324)
580–625
(304–330)
625–675
(330–358)
650–710
(343–377)
600–625
(316–330)
370–410
(188–210)
670–740
(354–393)
520–570
(271–300)
Mold
Temperature
250–300
(121–150)
175–240
(80–116)
190–300
(88–150)
225–325
(107–164)
250–325
(121–164)
190–250
(88–121)
290–375
(143–190)
150–200
(66–93)
Pack & Hold
Pressure
50%–75%
of Injection Pressure
Injection
Velocity
in/s
1.0–3.0
Back Pressure
psi
50
Screw Speed
rpm
50–90
Drying
Parameters
°F (°C)
6 hrs @ 175
(80)
4 hrs @ 250
(121)
4 hrs @ 275
(135)
4 hrs @ 250
(121)
3 hrs @ 300
(150)
2 hrs @ 200
(93)
3 hrs @ 275
(135)
4 hrs @ 180
(82)
Cushion
in
0.125–0.250
Screw
Compression
Ratio
2.5:1–3.5:1 2.0:1–2.5:1 2.5:1–3.5:1 2.5:1–3.5:1 2.5:1–3.5:1 2.5:1–3.5:1 2.5:1–3.5:1 2.5:1–3.5:1
Nozzle
Type
General
Purpose
General
Purpose
General
Purpose
General
Purpose
General
Purpose
General
Purpose
General
Purpose
Reverse
Taper
Clamp
Pressure
5–6 Tons/in2 of projected area of cavities and runner system
* Barrel temperatures should be elevated for compounds designed for electrical insulative properties.
Draft Angle • Maintain a minimum draft angle of 1/2° per side.
https://www.avient.com/sites/default/files/resources/PolyOne%2520India%2520Terms%2520and%2520Conditions%2520of%2520Sale%2520of%2520Products.May%25202016.pdf
Seller
makes no other warranties extending beyond the description of the
Product, whether used alone or in combination with any other substance
or in any process.
2.
Either party may suspend performance hereunder (except to
pay for Product already received) in the event of: (1) acts of God, fire,
explosion, flood, hurricanes; (2) strikes, lockouts or other industrial
disturbances or riots; (3) war, declared or undeclared, or acts of terrorism; (4)
compliance with any Federal, state, provincial, municipal or military law,
regulation, order, or rule, foreign or domestic, including priority, rationing,
allocation or preemption orders or regulations, or cancellation of Seller’s or
Buyer’s license to operate its plant; (5) catastrophic failure of facilities used
to manufacture Product, interruption or shortage of transportation, labor,
power, fuel or raw materials; (6) total or partial shutdown due to Seller’s
normal plant turnaround; or (7) any other cause or causes of any kind or
character reasonably outside the control of the party failing to perform,
whether similar or dissimilar from the enumerated causes (a “force
majeure”).
https://www.avient.com/sites/default/files/2024-03/ISO 9001 - NL027324 Current.pdf
To check this certificate validity ptease call: +31 (0) 88 450 5500
Page I of 2
R
[{$l'll.
fluA I
sYs.
248
Avient protective Materiats Urmonderbaan 22, 6167 RD Geteen,
The Nethertands
5750 Martin Luther King Jr.
https://www.avient.com/sites/default/files/2021-01/wire-and-cable-one-pager.pdf
APPLICATIONS: Power cables, Ethernet category cables, industrial cables, solar installation cables, coaxial cables,
fiber optics, hybrid cables
SYNCURE™
Cross-Linked Polyethylene for Power Cable Insulation
• Resistant to heat, oil, creep and abrasion
• Fast extrusion speeds
• UL 44 & UL 4703 flame performance
• UL/CSA bulletins
MAXXAM™ FR W&C
Flame Retardant Polypropylene for Category Cable
Insulation and Cross-Webs
• Alternative to FEP
• Low dielectric
• Thin wall extrusion capabilities
• UL 94 & plenum yellow card, V-2, V-0 & 5VA
fire performance ratings
FIRECON™
Flame Retardant Chlorinated Polyethylene
for Industrial Cable Jackets
• Resistance to harsh environments
• Low temperature properties
• UV resistance
• UL 44 flame performance
ECCOH™ LSFOH
Low Smoke and Fume, Non-Halogen for Insulation
and Jackets
• Low smoke and toxicity
• Improved fire safety
• Resistance to chemicals
• UL44 and CPR flame performance
ADDITIONAL SOLUTIONS
MAXXAM™ SY
Foamed Polypropylene for Coaxial Cable Insulation
SYNPRENE™
Flame Retardant Thermoplastic Elastomers
POLYMIX™
Customer Proprietary Formulations
For more information, please visit avient.com
or call +1.844.4AVIENT (+1.844.428.4368).
https://www.avient.com/sites/default/files/2020-11/eccoh-processing-guide.pdf
EXTRUDER
Screw 3/4" to 6" Polyethylene type—Single flight, no mixing section, 1.5–2:1 compression ratio
Tooling Semi-Pressure type: 30°–40° angle
Die On size with 1/8" or less land
L/D 24:1 recommended
Screen Pack No screen pack (Optional depending on pressure)
Cooling Trough 120–150°F (50–65°C) recommended
Feeder Gravimetric type preferred—3 compartment for cross-linked
Dryer
Desiccant type, 4 hours at 160°F (70°C) For ECCOH™ compound only; never put
Dry Silane in Dryers
PROCESSING
Temperature ECCOH 5000 Series ECCOH 6000 Series
Wire Preheat 180–250°F (80–120°C) 180–250°F (80–120°C)
Feed Zones 200°F (93°C) 275°F (135°C)
Transition 275°F (135°C) 325°F (163°C)
Metering 300°F (150°C) 375°F (190°C)
Head/Die 330°F (165°C) 420°F (215°C)
Target Melt 330–340°F (165–170°C) 420–440°F (215–225°C)
Flame at Die Tip Yes—as needed
Line Speed Shear sensitive: Observe Melt Temperature, Motor Amperage, and Pressure
Purge Compound HDPE
Copyright © 2020, Avient Corporation.
https://www.avient.com/sites/default/files/resources/Investor%2520Day%2520-%2520May%25202012%2520-%2520Global%2520Engineered%2520Materials.pdf
Nikrant
Page 67
United
States
36%
Europe
36%
Canada
2%
Asia
20%
Latin
America
2011 Revenue: $0.6 Billion2011 Revenue: $0.6 Billion SolutionsSolutions
At a Glance
Global Specialty Engineered Materials
Appliance
6% Building &
Construction
3%
Wire & Cable
14%
Electrical &
Electronics
14%Consumer
21%
Packaging
5%
Industrial
8%
Misc.
3%
HealthCare
5%
Transportation
21%
America
6%
2011 Revenue by Industry Segment2011 Revenue by Industry Segment
1.1%
1.3%
3.4%
5.1%
9.6%
8.0%
12-16%
2006 2007 2008 2009 2010 2011 2015
Operating Income % of Sales
Target
Expanding ProfitsExpanding Profits
Page 68
Value Proposition
• GSEM is a global leader providing complete specialty solutions encompassing
innovative technologies and services to enable customer success
Transformation Highlights
• Dramatic turnaround of the Engineered Materials business through mix
improvement and specialty focus
Value Proposition and Transformation Highlights
Global Specialty Engineered Materials
improvement and specialty focus
• GLS acquisition successfully integrated, having more than
doubled earnings in 3 years
• PolyOne culture and strategy now engrained worldwide
• Expansion into healthcare with dedicated resources
> $15B Addressable Market
Page 69
• Polymer design, formulation and service expertise
• Broad, global technology base and regional centers
of excellence
• Ten innovation centers around the world
Key Differentiators
Global Specialty Engineered Materials
• Ten innovation centers around the world
• Specialty brand leadership with
PolyOne, GLS, NEU and ECCOH
• Ability to leverage global key
account team
Page 70
From Volume
Commodity-driven product portfolio
To Value
Specialty technology and solutions
EM North America Transformation
Volume Sales Gross Margin $
Mix Transformation – Executing the Strategy
Global Specialty Engineered Materials
2006 2011 2006 2011 2006 2011
Page 71
$12
$29
Operating Income
($ in millions)
• Provided access to new customers
in specialized, high-growth markets
such as healthcare and consumer
• Strategic partner to many of the
world’s best-known companies
GLS Integration Success
16.9%
8.2%
2007 2011
2007 2011
Working Capital % of Sales
• Complementary global footprint
provided additional cross-selling
opportunities
• Opportunity to expand margins
and drive working capital
improvement while remaining
customer-focused
Page 72
$1.3
$27.6
2006 2011
Healthcare Revenue
• Investment in dedicated
healthcare team to drive
penetration and growth
• Leverage product portfolio
globally & win specialty business
Areas of Focus
Global Specialty Engineered Materials
$10.5
$117.9
2006 2011
Consumer Revenue
2006 2011globally & win specialty business
in targeted markets
• Aggressively commercialize
specialty innovation platforms
• Utilize our innovation centers to
influence OEM design
(Revenue in $ millions)
Page 73
• Carbon Nanotube Formulations
� Applications: Semiconductor equipment, hard drives
� Customer benefits: Scrap cost reduction and
clean conductivity
• Thermally Conductive Solutions
Applications: Sockets and bulb holders for LED lighting
Key Innovations
Global Specialty Engineered Materials
� Applications: Sockets and bulb holders for LED lighting
� Customer benefits: Cost reduction, energy saving, and
design flexibility
• FDA-Regulated TPEs
� Applications: Food packaging seals, intravenous delivery
systems, medical stoppers, prefilled syringes
� Customer benefits: Clean and safe elastomers for highly
regulated applications
Page 74
Critical Imperatives and 2015 Goal
Global Specialty Engineered Materials
Critical Imperatives
• Commercialize critical new technology platforms
• Manage the mix as we continue to drive
the transformation
• Global translation of commercial successes
2015 Goal
• 12 - 16% return on sales
Page 75
Page 76
https://www.avient.com/sites/default/files/2023-05/Cesa Stat Product Selector Guide.pdf
Most temporary antistatic additives
require time to reach maximum effectiveness,
typically 2 to 7 days.
https://www.avient.com/sites/default/files/2023-06/Cesa_ Stat Antistatic Additives for Automotive - Application Bulletin.pdf
Cesa Stat Antistatic Additives for automotive can
support customers with electrostatic decay time
testing according to Standard DIN EN 61340-2-1
to speed up the development.
https://www.avient.com/sites/default/files/2023-08/EVSE Industry Bulletin.pdf
Electric Vehicle (EV) Charging Market
Solutions for Level 1, 2, and DC public charging equipment
INDUSTRY BULLETIN
With funding a priority for the industry,
considerable growth of the infrastructure
supporting the EV charging market is expected.