https://www.avient.com/sites/default/files/2024-07/woonkeatmoh_2024.pdf
He is based in Avient’s world headquarters located outside Cleveland, Ohio.
https://www.avient.com/sites/default/files/2024-03/Aircraft Flooring Case Study Snapshot.pdf
A I RC R A F T I N T E R I O R
O E M
A I R C R A F T F L O O R I N G
• Meet aircraft flammability requirements (FAA)
• Provide flame retardance and smoke mitigation
• Maintain physical properties
• Control viscosity and allow enhanced processability
• Retain product integrity as contaminant free
• Provide product traceability
• Provided strong global EHS and regulatory support
to minimize risk
• Offered a solution to improve quality consistency and
control viscosity
• Enhanced mixing capability and improved
processing temperature and imprint hold
• Allowed greater security of supply with multiple
manufacturing locations
• Provided an integrated solution of plastisols and
pigment dispersions that met traceability
requirements with JIT delivery
KEY REQUIREMENTS
QUALITY + PERFORMANCE
WHY AVIENT?
https://www.avient.com/sites/default/files/2024-02/Gordon Glass Distributor List.pdf
SUSTAINING A LEGACY
Avient is proud to support the art and tradition of bow building by
offering Gordon Glass™ laminates to independent bowyers of any size or
location through our authorized distributors.
https://www.avient.com/sites/default/files/2022-08/ISO9001-2015 EN -EM.pdf
Zwolseweg 1, 2994 LB, Barendrecht, Netherlands - TEL: +31(0)102922689. www.dnv.com/assurance
Page 2 of 2
Appendix to Certificate
Polyone - Suzhou, China
Locations included in the certification are as follows:
Site Name Site Address Site Scope
PolyOne Management
(Shanghai) Co., Ltd.
https://www.avient.com/sites/default/files/2022-09/FR Healthy Bldg Codes Application Snapshot.pdf
P R O F I L E / S H E E T E X T R U D E R
R A I L S A N D K I C K P L A T E S
• Convert existing PVC profile and sheet rails and kick plates to
polyolefin resin to meet Class A fire safety (ASTM E84)
• Provide a system that meets healthy building certifications
and approvals
• Utilize a more sustainable flame retardant technology,
removing brominated or halogenated flame retardants from
the environment
• Achieve non-compromising performance in aesthetics,
impact, dimensional stability, CLTE, and E84 testing
• Provided broad flame retardant platform, backed by
extensive application and industry expertise, to meet
global flammability standards
• Has largest UL94 recognized Prospector membership
with HB, V-0, V-1, V-2 and 5VA/5VB ratings, and broad
glow wire performance products
• Included in-house UL certified labs and manufacturing
locations to perform UL94 material sampling and testing
• Supported application development to meet fire safety
standards, address current or emerging healthy building
codes, smart home requirements, and LEED credits
• Offered custom formulations in small lot quantities
Cesa™ Flam Non-Halogen Flame Retardants
KEY REQUIREMENTS
WHY AVIENT?
https://www.avient.com/sites/default/files/2021-04/shanghai-9001.pdf
TEL:+31(0)102922689. www.dnvgl.com/assurance
Page 2 of 2
Appendix to Certificate
PolyOne-Shanghai, China
Locations included in the certification are as follows:
Site Name Site Address Site Scope
PolyOne Polymer (Tianjin)
Company Limited
No.28#C, Jin Bin Hi-Tech
Industrial Park, 156 Nan Hai Road,
Tianjin Economic-Technological,
Tianjin, China, 300457
Manufacture of Masterbatch
PolyOne-Shanghai, China No. 88, Guo Shou Jing Road, Z.
https://www.avient.com/sites/default/files/2024-12/ISO-9001_English_Shanghai Zhangjiang.pdf
Zwolseweg 1, 2994 LB, Barendrecht, Netherlands - TEL: +31(0)102922689. www.dnv.com/assurance
Page 2 of 2
Appendix to Certificate
PolyOne-Shanghai, China
Locations included in the certification are as follows:
Site Name Site Address Site Scope
PolyOne Polymer (Tianjin) Company
Limited
No. 28#C, Jin Bin Hi-Tech Industrial Park,
No. 156, Nan Hai Road, Tianjin Economic-
Technological Development Area, Tianjin,
China 300457
Manufacture of Colour and Additive
Concentrates
PolyOne-Shanghai, China No. 88, Guo Shou Jing Road, Z.
https://www.avient.com/sites/default/files/2020-10/luxury-closures-gravi-tech-design-guide-2.0-application-specific.pdf
Gating Location
Choosing the correct gate location is an
extremely important part of the mold design
process .
Also, in a
location that will prevent weld line .
Gate
type should be selected based on location and
part geometry .
https://www.avient.com/sites/default/files/2021-06/fl.datasheet-pultrusion.pdf
MOVING HIGH PERFORMANCE FIBERS FORWARD
LOCATIONS
Headquarters, R&D, Manufacturing
FIBER-LINE® LLC
3050 Campus Drive
Hatfield, PA 19440
+1 215.997.9181
fiber@fiber-line.com
Manufacturing Operations
FIBER-LINE® LLC
280 Performance Drive SE
Hickory, NC 28602
+1 828.326.8700
fiber@fiber-line.com
EMEA & Asia Pacific Operations
FIBER-LINE® INTERNATIONAL B.V.
https://www.avient.com/sites/default/files/2020-09/surround-processing-guide-2020.pdf
TEMPERATURE
Material
Rear
°F (°C)
Center
°F (°C)
Front
°F (°C)
Nozzle
°F (°C)
Melt
°F (°C)
Mold
°F (°C)
Nylon 6,6
14% NiCF
540–570
(280–300)
530–560
(275–290)
530–560
(275–290)
540–570
(280–300)
540–570
(280–300)
200–300
(90–150)
Nylon 6,6
30% SS
540–570
(280–300)
530–560
(275–290)
530–560
(275–290)
540–570
(280–300)
540–570
(280–300)
200–300
(90–150)
PBT
14% NiCF
510–410
(265–280)
490–540
(255–280)
480–530
(250–275)
480–530
(250–275)
480–530
(250–275)
150–250
(65–120)
PC
14% NiCF
540–570
(280–300)
540–570
(280–300)
530–560
(275–290)
530–560
(275–290)
530–560
(275–290)
150–250
(65–120)
ABS
14% NiCF
470–520
(240–270)
460–520
(240–270)
460–520
(240–270)
460–530
(240–275)
460–530
(240–275)
100–200
(40–90)
PP
14% NiCF
440–480
(225–250)
440–480
(225–250)
430–470
(220–245)
420–460
(215–240)
420–460
(215–240)
125–175
(50–80)
DRYING
Material
Temperature
°F (°C)
Time
Minimum
Moisture
Maximum
Moisture
Nylon 6,6
14% NiCF
180 (80) 4–5 hours 0.05% 0.20%
Nylon 6,6
30% SS
180 (80) 4–5 hours 0.05% 0.20%
PBT
14% NiCF
250 (120) 6-8 hours 0.02% 0.03%
PC
14% NiCF
250 (120) 3–4 hours 0.02% 0.02%
ABS
14% NiCF
200 (90) 2–4 hours 0.05% 0.10%
PP
14% NiCF
180 (80) 2–4 hours 0.20% 0.30%
Equipment
• Feed throats smaller than 2.5" may cause bridging due to pellet size
- Larger feed throats will be more advantageous with long fiber EMI shielding resins
• General purpose metering screw is recommended
- Mixing/barrier screws are not recommended
• L/D ratio
- 18:1–20:1 (40% feed, 40% transition, 20% metering)
• Low compression ratio
- 2:1–3:1
• Deep flights recommended
- Metering zone 3.5 mm
- Feed zone 7.5 mm
• Check ring
- Three-piece, free-flowing check ring
• General purpose nozzle (large nozzle tips are recommended)
- Minimum orifice diameter of 7/32"
- Tapered nozzles are not recommended for long fiber EMI shielding resins
• Clamp tonnage:
- 2.5–5 tons/in2
Gates
• Large, free-flow gating recommended
- 0.25" x 0.125" land length
- 0.5" gate depth
Runners
• Full round gate design
• No sharp corners
• Minimum of 0.25" diameter
• Hot runners can be used
PROCESSING
Screw Speed Slower screw speeds are recommended to protect fiber length
Back Pressure Lower back pressure is recommended to protect fiber length
Pack Pressure 60–80% of max injection pressure
Hold Pressure 40–60% of max injection pressure
Cool Time 10–30 seconds (depends on part geometry and dimensional stability)
PROCESS CONSIDERATIONS
Recommended – retain fiber length (maximize conductivity)
• Low shear process
• Low screw speed and screw RPM
• Slow Injection speed
• Fill to 99–100% on first stage of injection
- Reduces potential nesting of fibers at gate location
- Improves mechanical performance near gate location
- Promotes ideal fiber orientation
Resin Rich Surface
• Achieved when using a hot mold temperature and longer cure times
≥ Max mold temperature recommendation
• Improved surface aesthetic
• Reduced surface conductivity
• Could reduce attenuation performance in an assembly
Fiber Rich Surface
• Achieved when using a cold mold temperature and shorter cure times
≤ Minimum mold temperature recommendation
• Improved surface aesthetic
• Reduced surface conductivity
• Could improve attenuation performance in an assembly
www.avient.com