https://www.avient.com/sites/default/files/2024-10/Avient_CodeConduct_2024_final2.pdf
• Complete required compliance and ethics training and certifications.
Each of us has the responsibility to prepare and maintain accurate information and complete records.
You are also responsible for completing expense reports accurately and in a timely fashion.
https://www.avient.com/sites/default/files/2020-12/maxxam-fr-case-study.pdf
After Avient delivered test data for pair combinations and the manufacturer’s team completed material trials, they were able to replace FEP with Maxxam FR material in four out of four insulation pairs.
https://www.avient.com/sites/default/files/2024-02/US_OH_North Baltimore_ ISO_IEC 17025.pdf
No. 0562.01) Revised 05/31/2022 Page 1 of 1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 AVIENT CORPORATION 733 East Water Street North Baltimore, OH 45872 Claire Holman Phone: (419) 257-1327 MECHANICAL Valid To: October 31, 2023 Certificate Number: 0562.01 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following automotive plastics tests: Test Method: Test Name: ASTM D412 Tensile ASTM D523 Specular Gloss ASTM D618 (A) Conditioning of Plastics ASTM D624 (Die C) Tear Strength ASTM D638 Tensile Properties ASTM D792 (A) Density and Specific Gravity by Displacement ASTM D1004 Initial Tear Resistance ASTM D1203 (A) Volatile Loss ASTM D1895 (A) Apparent Density, Bulk Factor, Pourability ASTM D1921 Particle Size (Sieve Analysis) ASTM D2240 Durometer Hardness (Shore A and D) ASTM E1331 Color by Spectrophotometry Using Hemispherical Geometry FMVSS 571.302 Flammability FORD BN-102-01 (A) Low Temperature Flexibility FORD BO-131-03 Interior Odor ISO 3795 Determination of Burning Behavior of Interior Materials SAE J323 (A) Cold Cracking (Mandrel Bend) SAE J1351 Hot Odor for Insulation Materials SAE J1545 Instrumental Color Difference Measurement SAE J1756 Fogging Characteristics of Interior Automotive Materials (Photometric Only) DOC-058151 Angle of Repose 1 Laboratory Developed Method For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation.
https://www.avient.com/sites/default/files/2024-12/Avient Norwalk A2LA ISO17025-17.pdf
No. 0962.01) 09/05/2023 Page 1 of 1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 AVIENT CORPORATION 80 North West Street Norwalk, OH 44857 Craig Polta Phone: 419 660 4278 MECHANICAL Valid To: September 30, 2025 Certificate Number: 0962.01 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following tests on plastics: Test Method(s) Test Name ASTM D256; ISO 180 Notched Izod ISO 179 (1eA) Determination of Charpy Impact ASTM D523 Gloss ASTM D618 (Method A) Conditioning of Test Specimens ASTM D792 (Method A) Specific Gravity ASTM D1238 (Method B) Melt Flow Rate ASTM D3012 Thermal Oxidative Stability ASTM D3641 Injection Molding Test Specimens FMVSS 302 Flammability ASTM E1331; SAE J1545 Spectrophotometric Color Difference SAE J1885 (Rev.
https://www.avient.com/sites/default/files/2025-07/ISO IEC 17025 Chemical Avon Lake.pdf
No. 0514.02) 12/11/2023 Page 1 of 1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 AVIENT CORPORATION – ANALYTICAL SOLUTIONS 33587 Walker Road Avon Lake, OH 44012 Stephanie Mims Phone: 440-930-3499 CHEMICAL Valid To: September 30, 2025 Certificate Number: 0514.02 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following rubber and plastics tests: Test Description: Test Method or Standard: FTIR (Fourier Transform Infrared) Spectroscopy ASTM E1252 (Except 7.6, 11.2, and 11.4) Flammability Horizontal Burn of Self-Supporting Plastics ASTM D635; UL 94; IEC 60695-11-10 Horizontal Burn of Materials Used in Occupant Compartments of Motor Vehicles ASTM D5132; FMVSS 302 (49 CFR 571.302); ISO 3785 Vertical Burn, 20 mm ASTM D3801; UL 94; IEC 60695-11-10 Vertical Burn, 125 mm ASTM D5048; UL 94; IEC 60695-11-20 Thin Material Burning Test UL-94 Glow Wire Test IEC 60695 2-10, 2-11, 2-12, 2-13 Thermal Analysis DSC (Differential Scanning Calorimetry) ASTM D3418, E794, E1356 TGA (Thermogravimetric Analysis) ASTM E1131 TMA (Linear Thermal Expansion of Solid Materials by Thermomechanical Analysis) ASTM E831; ISO 11359-2 Karl Fischer Moisture Content ASTM D6869 For the tests to which this accreditation applies, please refer to the laboratory’s Chemical Scope of Accreditation.
https://www.avient.com/sites/default/files/2025-07/ISO IEC 17025 Mechanical Avon Lake.pdf
No. 0514.01) 12/11/2023 Page 1 of 1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 AVIENT CORPORATION – ANALYTICAL SOLUTIONS 33587 Walker Road Avon Lake, OH 44012 Stephanie Mims Phone: 440 930 3499 MECHANICAL Valid To: September 30, 2025 Certificate Number: 0514.01 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following rubber and plastics tests: Test Description Test Method or Standard Brittleness Temperature (Impact) ASTM D746; ISO 812 Charpy Impact ISO 179-1 Color Determination by Spectrophotometer ASTM D2244, E1331; ISO 7724 Conditioning of Plastics for Testing ASTM D618; ISO 291 Deflection Temperature Under Flexural Load ASTM D648; ISO 75-1, -2 Durometer Hardness (Shore A and D) ASTM D2240; ISO 7619-1 Flexural Properties ASTM D790; ISO 178 Flow Rate (Extrusion Plastometer) ASTM D1238 (Procedures A and B); ISO 1133 Impact Resistance (Izod) ASTM D256; ISO 180 Instrumented Impact ASTM D3763; ISO 6603-2 Specific Gravity/Density ASTM D792 (Method A); ISO 1183-1 Specular Gloss ASTM D523; ISO 2813 Tackiness of Interior Materials BO 061-01 Tear Resistance ASTM D624, D1004; ISO 34 Tensile Properties ASTM D412 (Method A), D638, D882; ISO 37, 527-1, -2, -3, -4, -5 Xenon-Arc Exposure Testing ASTM D2565, G155; SAE J1885 (Withdrawn January 2008), J1960 (Withdrawn January 2008), J2412, J2527; BO-116-01 For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation.
https://www.avient.com/sites/default/files/2021-01/w-9-clariant-plastics-coatings-usa-llc-july-20201.pdf
If you are a nonresident alien or a foreign entity, give the requester the appropriate completed Form W-8 or Form 8233.
If the owner of the disregarded entity is a foreign person, the owner must complete an appropriate Form W-8 instead of a Form W-9.
Complete the certification as indicated in items 1 through 5 below.
https://www.avient.com/sites/default/files/2021-09/neu-sales-terms-and-conditions.9-16-212.pdf
Buyer shall accept, as full and complete performance by Seller, deliveries in accordance with such determinations as Seller may make.
These Terms, together with (i) the product description, quantity, price, and payment terms stated on Seller’s order confirmation, (ii) any credit agreement, and (iii) the Specifications, if any, constitute the complete and final agreement and understanding between Seller and Buyer relating to the Product and supersede all prior oral or written communications, agreements, understandings, representations, statements, and assurances between the parties.
https://www.avient.com/sites/default/files/resources/PDI_Healthcare_Brochure_2011_0.pdf
PDI) is a complete solutions provider of plastics testing and polymer consulting within the medical materials and device industries.
PDI) is a complete solutions provider of plastics testing and polymer consulting within the medical materials and device industries.
https://www.avient.com/sites/default/files/2020-09/crtm-panel-product-bulletin-2020.pdf
The unique manufacturing process yields uniform quality throughout the panel, ensuring complete resin impregnation, high fiber volume content, low void content, uniform thickness, and core bonding throughout.