https://www.avient.com/news/avient’s-newest-trilliant-hc-materials-stand-disinfectants-better-alternative-fr-polymers
Homepage
//
News Center
//
Avient’s Newest Trilliant™ HC Materials Stand Up to Disinfectants Better Than Alternative FR Polymers
These materials feature improved chemical resistance to trusted hospital-grade disinfectants over other flame-resistant (FR) polymers such as PC/ABS, PC/PET, and copolyester.
Using a method adapted from ASTM D543 for ESCR (environmental stress cracking resistance), results versus alternative FR materials demonstrate superior mechanical and aesthetic property retention, and prevention of cracks and crazing after exposure to leading healthcare disinfectants* such as Virex® Tb, CaviCide™, Vesphene® IIse and Super Sani-Cloth®¹.
https://www.avient.com/sites/default/files/2023-03/Silcosperse Flame Retardant Additives Product Bulletin %281%29.pdf
MATERIAL PROPERTY
SILCOSPERSE FR
107443
SILCOSPERSE FR
HS 107449
SILCOSPERSE FR
HS-B 107453
Silicone X X X
Ceramifier
Material ceramifies, it doesn’t char.
https://www.avient.com/sites/default/files/2023-01/Disinfectant Resistant Trilliant and Versaflex HC Materials Program Bulletin_0.pdf
Virex® Tb Vesphene™ IIse CaviCide™
Trilliant™ HC 8910 +++ +++ +++
Trilliant™ HC 8920 (FR) – +++ +++
FR PC/PET – + ++
FR COPE (copolyester) + ++ +++
Tensile Strength Property Retention After 72-hour Continuous Exposure
+++ Best (>90% retention),
++ Better (50-90% retention),
+ Good (
Average Peel Strength (PLI) Versaflex™ HC OM 8940
Trilliant™ HC 8910 16.3
Trilliant™ HC 8920 FR 17.0
https://www.avient.com/sites/default/files/2022-11/Bergamid -Battery Pack-Application Snapshot.pdf
SBD CORDLESS
POWER TOOL
B A T T E R Y P A C K
• PA66-based solution
• Meet flame retardant UL94 V-0 standard
• Pass 10-meter drop test
• Achieved flame retardance of UL94 V-0
rating @1.5 and 3.0 mm, GWFI 750 °C
• Offered material and high impact with good
laser marking performance strength
• Accomplished excellent surface appearance
with less visible fibers
• Provided shorter lead time and stronger
technical support than the competition
Bergamid™ FR Non-Halogen Flame Retardant
Formulation
KEY REQUIREMENTS
WHY AVIENT?
LEARN MORE
https://www.avient.com/products/engineered-polymer-formulations/flame-retardant-formulations/bergamid-fr-non-halogen-flame-retardant-formulations
https://www.avient.com/sites/default/files/2022-11/Bergamid_Battery Frame - Application Snapshot.pdf
SOLAR ENERGY
COMPANY
B A T T E R Y F R A M E
• Good dimensional stiffness at high operating temperatures
• Eco-conscious performance of a non-halogenated fire
retardant
• Easy processing
• Met regulatory requirements of UL 746C for
ultraviolet light, water, and immersion
exposures
• Delivered excellent high heat and eco-
friendly performance of non-halogenated
flame resistance
• Offered prompt development and on-site
technical services to accelerate the speed-
to-market
Bergamid™ FR Non-Halogen Flame
Retardant Formulations
KEY REQUIREMENTS
HIGH HEAT FLAME RESISTANCE
WHY AVIENT?
LEARN MORE
https://www.avient.com/products/engineered-polymer-formulations/flame-retardant-formulations/bergamid-fr-non-halogen-flame-retardant-formulations
https://www.avient.com/sites/default/files/2023-10/Syncure XLPE 200 Series DBDPE-free Grades Product Bulletin.pdf
This literature shall NOT operate as permission, recommendation, or inducement to practice any patented invention without permission of the patent owner.
1.844.4AVIENT
www.avient.com
System
Syncure XLPE
S200FH
Syncure XLPE
S200FV
Applications
Building Wire, Tray Cable,
Service Entrance
Building Wire, Tray Cable,
Service Entrance
Specification UL 44 UL 44
Wire Type
RHW-2, RHW, RHH, XHHW-2,
XHH, XHHW, SIS
RHW, RHH, RHW-2
Components
78% S1054A
22% SC5400-0002 RoHS
MB ALT FR
50% S1054A
50% SC5400-0003 RoHS
MB ALT FR
Features Horizontal Flame, DBDPE-free VW-1, DBDPE-free
General Properties
Specific Gravity (g/cm3) 1.01 1.31
Hardness Shore D, 10sec 47 48
Gel % 68 70
Tensile Properties
Tensile Strength (psi) 2800 3200
Elongation % 400 470
Tensile Retention % 95 100
Elongation Retention % 90 93
Electrical
Dielectric Strength (V/mil) 1000 1200
Dielectric Constant 2.31 2.61
Dissipation Factor % 0.0012 0.0043
Thermal
Temperature Rating °C 90 90
Heat Deformation % 10 5
TECHNICAL PROPERTIES
https://www.avient.com/sites/default/files/2021-04/trilliant-hc8900-medical-device-housing-case-study.pdf
DEVICE
MANUFACTURER
M E D I C A L D E V I C E H O U S I N G
• Improved chemical resistance compared to PC/ABS,
PC/PET & COPE
• Flame retardant (FR) rating of V-1 at 0.75 mm
• Zero BPA & non-halogenated FR material
• Available in standard hospital grade pre-colors
• Provided a cost-effective material with superior
chemical resistance to traditional materials
• Formulated a medical-grade, semi-crystalline
blend to support regulatory testing and
approvals
• Demonstrated superior property retention and
crack resistance after exposure to hospital-
grade disinfectants, including Virex® Tb,
helping to extend the device life
Trilliant™ HC8900 Thermoplastics
KEY REQUIREMENTS
WHY AVIENT?
https://www.avient.com/sites/default/files/2023-10/2023 Syncure Wire and Cable Product Selection Guide.pdf
Syncure™ XLPE
Cross-linkable
Polyethylene
Formulations
FOR LOW VOLTAGE CABLES
PRODUCT SELECTION GUIDE
Syncure™ XLPE
MOISTURE CROSS-LINKABLE POLYETHYLENE INSULATION FOR LOW VOLTAGE CABLE SYSTEMS
SYSTEM S100FH S100FH-XUV S100FH-UV S100FV S100FV-UV S112NA S120NA S200FH S200FV
Applications
Building Wire,
Tray Cable
Building Wire,
Tray Cable
Photo-Voltaic (PV)
Wire
Building Wire,
Tray Cable
Building Wire,
Tray Cable
Building Wire,
Teck-90
Pipe and Tube
Building Wire, Tray Cable,
Service Entrance
Building Wire, Tray Cable,
Service Entrance
Specification UL 44 UL 44 UL 44, UL 4703 UL 44 UL 44 CSA 22.2
Suitable for
NSF 61
UL 44 UL 44
Wire Type
XHHW-2, RHW-2, USE-2,
SIS
XHHW-2, RHW-2, USE-2,
SIS
XHHW-2, RHW-2,
USE-2, SIS, PV
XHHW-2, RHW-2,
SIS
XHHW-2, RHW-2,
USE-2, SIS, PV
RW-90, Teck-90 –
RHW-2, RHW, RHH,
XHHW-2, XHH, XHHW, SIS
RHW, RHH, RHW-2
Components %
83% S1054A
17% V0022G RoHS
83% S1054A
17% V0022G-UV RoHS
70% S1054A
30% V0022G-UV RoHS
50% S1054A
50% V0044G RoHS
50% S1054A
50% V0044G-UV RoHS
95% S1054A
5% S1000B
95% S1016A
5% S1037B
78% S1054A
22% SC5400-0002 RoHS
MB ALT FR
50% S1054A
50% SC5400-0003 RoHS
MB ALT FR
Features
Horizontal
Flame
Horizontal Flame,
UV Resistant,
Colors Possible
Horizontal Flame,
FV-1 Flame, UV Resistant,
Colors Possible
VW-1
VW-1, UV Resistant,
Colors Possible
Non-FR Rigid Pipe Applications
Horizontal Flame,
DBDPE-free
VW-1, DBDPE-free
GENERAL PROPERTIES
Specific Gravity 1.01 1.02 1.10 1.31 1.31 0.92 0.95 1.01 1.31
Hardness Shore D,
10 Seconds
47 47 47 48 48 47 59 47 48
Gel 68 68 70 70 70 72 72 68 70
TENSILE PROPERTIES
Tensile Strength
(psi) 2800 2500 2650 3200 2650 2800 4500 2800 3200
Elongation % 400 400 540 470 540 400 80 400 470
Tensile
Retention %
100 100 97 110 110 95 75 95 100
Elongation
Retention %
90 90 94 100 100 90 75 90 93
ELECTRICAL
Dielectric
Strength (V/mil) 1000 1400 1400 1200 1200 1000 – 1000 1200
Dielectric
Constant
2.31 2.45 2.61 2.61 2.61 2.24 2.1 2.31 2.61
Dissipation
Factor %
0.0012 0.0080 0.008 0.0043 0.0043 0.0008 0.002 0.0012 0.0043
THERMAL
Temperature
Rating °C
90 90 90 90 90 90 125 90 90
Heat
Deformation %
10 5 5 5 5 10 10 10 5
The Syncure™ XLPE portfolio is a two-step, silane-
grafted, moisture cross-linkable polyethylene system.
https://www.avient.com/sites/default/files/2023-10/Wire _ Cable Tri-fold Selection Guide_0.pdf
PRODUCT SELECTION GUIDE
WIRE & CABLE
SOLUTIONS
Specialty Engineered
Materials
High performance insulation, jacketing,
and cross-web formulations for the
wire and cable industry
Syncure™ XLPE Cross-linkable
Polyethylene Formulations
• Ambient curing
• Flame performance
• Resistant to heat, oil, creep,
& abrasion
• Low temperature properties
• Low capital investment
• High extrusion speeds
• DBDPE-free grades available
• UL/CSA bulletins
Maxxam™ FR Flame Retardant
Polyolefin Formulations
• FEP alternative
• Fire performance
• UL 444 & plenum yellow
card compliance
• Low dielectric
• High extrusion speeds
• Thin wall extrudability
Maxxam™ SY Foamable Flame
Retardant Formulations
• Low dielectric
• Uniform cell structure
• Crush & heat resistance
• Ease of chemical foaming
ECCOH™ Low Smoke and Fume
Non-Halogen Formulations
• Improved fire safety
• Low smoke, fume, non-halogen
(LSFOH) formulations
• Chemical resistance
ECCOH™ XL Cross-Linkable Solutions
• Non-halogen, low smoke, toxicity,
& corrosiveness
• Excellent mechanical & electrical
properties
• Easily processed
• Operating temperature of 90°C
• Moisture cure technology
Synprene™ Flame Retardant
Thermoplastic Elastomers
• Flexibility
• Flame performance
• Low temperature
brittleness (LTB) resistance
• Chemical resistance
• Easily colored
FireCon™ CPE Insulation Jacketing
Formulations
• Resistance to harsh environments
• Low temperature performance
• Flame performance
• High extrusion speeds
• Sunlight resistance
FEATURES SPECIFICATION
ECCOH™ XL 8148 Non-halogen, low smoke, toxicity, & corrosiveness EN50618
Syncure™ S100FH Horizontal flame UL 44
Syncure™ S100FH-XUV Horizontal flame, UV resistant UL 44
Syncure™ S100FH-UV Horizontal flame, FV-1 flame, UV resistant UL 44, UL 4703
Syncure™ S100FV VW-1 flame UL 44
Syncure™ S100FV-UV VW1, UV resistant UL 44
Syncure™ S112NA Non-flame retardant CSA 22.2
Syncure™ S120NA Non-flame retardant NSF 61
Syncure™ S200FH Horizontal flame, DBDPE-free UL 44
Syncure™ S200FV VW-1, DBDPE-free UL 44
INSULATION FOR POWER CABLE SYSTEMS
Low Voltage Power Cables
• Flame performance
• Resistance to heat, oil, creep, & abrasion
• Low temperature performance
• Low capital investment
• High extrusion speeds
INSULATION & CROSS-WEBS FOR DATA CABLE SYSTEMS
Category Cables
• FEP alternative
• Flame performance
• Low dielectric constant
• High extrusion speeds & thin wall capability
• Chemical resistance
• Low temperature performance
• Flexibility
FEATURES SPECIFICATION
Maxxam™ FR 0521-48 R1 Low smoke & fume, non-halogen UL 444
Maxxam™ FR 0587-21 R3 Halogenated to plenum performance UL 444
Optical Fiber Cables
• Resistance to harsh environments, chemicals, & sunlight
• Low temperature brittleness (LTB) resistance
• Low smoke & toxicity
• Flexibility
• High extrusion speeds
FEATURES SPECIFICATION
ECCOH™ 6649 UV Low DD Low smoke & fume, non-halogen Meets customer-specific flame requirements
Coaxial Cables
• Flexibility
• High extrusion speeds
• Low dielectric constant
• Uniform cell structure
• Crush & heat resistance
FEATURES SPECIFICATION
Maxxam™ SY 89-22-7 Foamable Meets customer-specific flame requirements
JACKETING FOR POWER & DATA CABLE SYSTEMS
Low & Medium Voltage Jacketing
• Resistance to harsh environments, chemicals, & UV degradation
• Low temperature brittleness (LTB) resistance
• Low smoke & toxicity
• Flexibility
• High extrusion speeds
• Easily colored
FEATURES SUBMARKETS & USES
FireCon™ CPE 30-33 RoHS Black Flame retardant, flexible Building & construction, industrial, nuclear
FireCon™ CPE 37-36 RoHS Black Flame retardant, flexible Building & construction, industrial, nuclear
FireCon™ CPE 30-20 RoHS Natural Flame retardant, flexible Building & construction, industrial, nuclear
ECCOH™ 5549 UV Low smoke & fume, non-halogen, flame retardant Building & construction, industrial
ECCOH™ 6649 UV Low DD Low smoke & fume, non-halogen, flame retardant Optical fiber, ducts
ECCOH™ 5981 UV Low smoke & fume, non-halogen, flame retardant Industrial, Teck 90 wire
Synprene™ RT5180 Flame retardant, LTB resistance Building & construction, industrial
Synprene™ RT5180UV Flame retardant, LTB resistance Building & construction, industrial
Synprene™ RT3870M Flame retardant, LTB resistance Building & construction, industrial
1.844.4AVIENT
www.avient.com
Copyright © 2023, Avient Corporation.
https://www.avient.com/sites/default/files/2023-03/Cergy-AVIENT LUXEMBOURG-2022-Décret 2021-461 Certfificate.pdf
MAIA+
N° rapport :223-2023-000066-FR 10898066 0.5
jour
Date Début / Fin :04/11/2022 /04/11/2022 PolyOne France - site de Saint Ouen l'Aumône 1 /11
ATTESTATION DE RECONNAISSANCE
Attribué à
PolyOne France - site de Saint Ouen l'Aumône
14 avenue de l'Eguillette / ZA du Vert Galant
95310 - SAINT OUEN L'AUMONE - FRANCE
Bureau Veritas Certification certifie que les prestations de l’entreprise susmentionnée
ont été évaluées et jugées conformes aux caractéristiques énoncées dans le décret
en vigueur à la date d’édition du présent certificat :
Décret n°2021-461 du 16 avril 2021 relatif à la
prévention des pertes de granulés de plastiques
industriels dans l’environnement
Sous réserve du respect des caractéristiques vérifiées, cette attestation est
valable jusqu’au : 16/02/2026
Date originale : 17/02/2023
Attestation n°: 223-2023-000066-FR Date : 17/02/2023
Affaire n°: 10898066
Laurent CROGUENNEC - Président
Adresse de l’organisme certificateur : Bureau Veritas Certification France
Le Triangle de l'Arche - 9 Cours du Triangle - 92937 Paris La Défense
Des informations supplémentaires concernant le périmètre de cette attestation ainsi que
l'applicabilité des exigences du décret peuvent être obtenues en consultant l'organisme.