https://www.avient.com/news/avient-launches-new-cross-linkable-formulations-photovoltaic-cables-support-rising-need-solar-power-generation
Caption: ECCOH™ XL 8148 solutions are suitable for photovoltaic cables used in solar power generation
The new ECCOH™ XL Cross-Linkable Solutions for photovoltaic cables are REACH compliant and rated for permanent outdoor use with good UV and weather resistance, passing Arrhenius lifetime prediction tests as per IEC 60216-1.
ECCOH XL Cross-Linkable Solutions for photovoltaic cables are currently manufactured in Europe and are available globally.
https://www.avient.com/news/archives?page=2
Avient Expands Flame Retardant Solutions Portfolio for Wire and Cable with ECCOH™ XL 8054
Avient Launches ECCOH™ XL 8054, Expanding Cross-Linkable Flame Retardant Solutions Portfolio for Wire and Cable
To download a high-resolution ima
https://www.avient.com/resources/safety-data-sheets?page=3044
ECCOH 5549
ECCOH 1092
ECCOH 5555
https://www.avient.com/resource-center?document_type=59&document_subtype=0&industry=0&product_family=0&product_name=0&op=FILTER RESULTS&form_id=resource_filter_form&page=15
ECCOH™ XL Cross-Linkable Solutions for Photovoltaic Cables - Product Bulletin
ECCOH XL 8148 for Photovoltaic Cable
ECCOH XL 8148 solutions bring UV resistance and fast processing to photovoltaic cable
https://www.avient.com/sites/default/files/2023-01/ECCOH XL 8148 - Photovoltaic Cable - Application Snapshot.pdf
Name of topic CABLE PRODUCER P H O T O V O L T A I C C A B L E • Simplified supply chain and inventory by providing one solution for both insulation and jacket coating • Provided a material that gave cable a good surface finish and improved cable life time value (passed Arrhenius life time prediction as per IEC 60216-1 in internal lab test) • Reduced catalyst dosage resulting in lower material cost • Improved customer processing speeds • Enabled flame retardant performance to EN 50618 and IEC 60332-1 standards on complete cable ECCOH™ XL 8148 + ECCOH XL CAT 005 Formulations KEY REQUIREMENTS WHY AVIENT?
All Rights Reserved https://www.avient.com/products/engineered-polymer-formulations/eco-conscious-formulations/eccoh-cross-linkable-solutions Cable producer
https://www.avient.com/sites/default/files/2023-01/ECCOH XL Cross-Linkable Solutions for Photovoltaic Cable _8148_ Product Bulletin.pdf
ECCOH™ XL Cross-Linkable Solutions for Photovoltaic Cables Enabling a more sustainable and safer planet, Avient has developed ECCOH™ XL Cross-Linkable Solutions for photovoltaic cable applications (ECCOH XL 8148).
KEY CHARACTERISTICS UV and Weather Resistance - ECCOH XL 8148 solutions are suitable for permanent outdoor use.
Flame Retardant Performance - ECCOH XL 8148 cable solutions are non-halogen flame retardant offering low smoke and fume performance.
https://www.avient.com/company/sustainability/sustainability-report/products/markets/5g-case-study
ECCOH™ Micromodules and ECCOH™ + Syncure™ 5G Hybrid Cable Insulation + Jacket materials are specifically designed to for optical fiber components.
https://www.avient.com/products/engineered-polymer-formulations/flame-retardant-formulations
ECCOH™ Low Smoke & Fume Formulations
ECCOH™ XL Cross-Linkable Solutions
ECCOH™ XL Cross-Linkable Solutions
https://www.avient.com/sites/default/files/2021-01/eccoh-selection-guide-cn.pdf
电线电缆对折页-210x285mm-CN1.8-1 电线与电缆 ECCOH™ 低烟、 无卤配方 www.avient.com 版权所有© 2020 埃万特公司。
+86-21-60284888 ECCOH™ ECCOH™无卤配方专为高阻燃性、低毒和 低烟密度设计,可应用于任何环境,尤其 适用于对烟雾减少有特别需求的地方, 如逃生方式受限的密闭空间(如酒店、大 型写字楼、沿海岸单体设施、火车、地铁 和船舶等)。
特点 电线和电缆 高度阻燃 毒性和烟密度极低 不同级层间可交联 可与色母料、添加剂浓缩液、紫外稳定剂一同加工 高度阻燃 毒性和烟密度极低 适合进行挤压和注射成型 管和配件 材料(ECCOH) 5924C 5920 5511C 5806UV 5127UV 5549/1 8300-8001 8300-8003 8300-8008 1125C 1052C 5309 5995/1C 5555C 5286 3140-3 6151 5865C XLS8002 6649 中低压电缆 光缆 机车/船 光缆 电缆/光缆 电子线 电缆 电子线 电子线 电缆 机车缆护套 电缆/光缆 电缆 机车缆 电缆 电缆/光缆 电缆 电缆 电缆/光缆 应用 热老化等级 热塑性 √ √ √ √交联型 交联方式 密度48 熔融指数(150℃/21.6kg) 硬度shore D 拉伸强度MPa 断裂伸长率% 氧指数% 耐环境应力开裂ESCR 阻燃性能 低温性能 耐油性能 耐UV性能 耐泥浆性能 低摩擦性能 产地 有焰(1mm)ASTM E662 无焰(1mm) 70 235 C类 √ √ √ 中国 45 265 中国 68 275 √ √ √ 欧洲 210 √ C类 中国 1.49~1.51 4.0 54 12.5 200 36 1.47 3.5 55 14 210 34 1.53 0.8 56 14 150 40 1.51 1 47 9.5 170 38 1.46 3.8 54 15.5 180 32 √ 中国 1.6 2.9 49 11.7 170 45 CPR B √ √ 中国/欧洲 1.29 13.5 48 17.5 345 27 FT-2 中国 1.27 9.5 48 13 360 29 90 190 √ 中国 1.49 8 53 15.7 245 35 63 180 √ 中国 1.54 2.7 55 11.5 180 40 106 214 CPR C √ √ 中国 1.5 8 50 12.5 180 34 84 206 C类 √ 中国 1.5 1.6 46 14 250 39 √ √ √ 欧洲 1.48 3 46 11 215 36 √ √ 欧洲 1.6 2.8 48 10.3 165 41 √ √ √ 欧洲 1.58 4.2 48 12.4 160 46 CPR B √ 欧洲 1.46 6 53 17 160 33 39 143 √ 欧洲 1.51 4 53 11.5 170 43 50 150 √ √ √ 中国 1.54 2.3 56 11.5 155 35 D类 中国 1.5 5.8 12 250 27 FT-2 中国 1.35 10 49 15 320 28 FT-2 中国 辐照/硅烷 辐照 辐照 辐照 辐照 辐照 自交联/水浴辐照/硅烷 √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ 90℃ 90℃ 90℃ 105℃ 90℃ 105℃ 125℃ 105℃ 105℃ 105℃ 90℃ 90℃ 90℃105℃ 105℃ 105℃ 105℃ 105℃ 加工方式(挤出) 材料性能:热塑状态(非交联后) 烟密度(最大) 特殊性能 ECCOH™低烟、无卤解决方案
https://www.avient.com/sites/default/files/2021-11/eccoh-5565-antenna-power-cable.pdf
CABLE MANUFACTURER A N T E N N A P O W E R C A B L E • Elongation at -40°C • High temperature bend test at 130°C • Low water absorption • Resistance to braided shielding • Fire performance to pass CPR class Dca • Provided best cold performance compared to competitor solutions • Enabled faster processing with increased line speed • Met material fire performance requirements and all other performance criteria ECCOH™ 5565 Formulation KEY REQUIREMENTS WHY AVIENT?
All Rights Reserv ed. https://www.avient.com/products/engineered-polymer-formulations/eco-conscious-formulations/eccoh-low-smoke-and-fume-non-halogen-formulations Cable manufacturer