https://www.avient.com/sites/default/files/2023-03/Artisan Pre-colored Thermoplastics Technical Bulletin.pdf
TECHNICAL BULLETIN Characteristics Artisan™ Nylon Solution Painted Metal Painted Plastic Traditional Molded-in Color Impact Modified Nylon PA Ionomer Alloy Aesthetic Very Good Excellent Excellent Good Very Good Very Good Scratch Appearance Excellent Poor Poor Good Excellent Excellent Scratch & Mar Resistance Very Good Excellent Excellent Poor Very Good Excellent Color Customization Good Excellent Excellent Very Good Good Good Stress Whitening Excellent Fair Fair Poor Excellent Excellent Weatherability Good Excellent Excellent Very Good Good Very Good Temperature Performance Good Excellent Fair Fair Fair Good Corrosion Resistance Excellent Fair Excellent Excellent Excellent Excellent Processability One Step Multi Step Multi Step One Step One Step Complex One Step Total Production Cost $$$ $$$$$ $$$$ $$ $$$ $$$$ Order Quantity Restrictions Some Some Some None More More COMPARISON OF NYLON, METAL, AND PLASTIC Properties Test Method Artisan™ AR6000-0007 HI UV* Gloss Level** Gloss reading at 60 degrees 80-93 Molding Shrinkage – Across Flow ASTM D955 0.009 to 0.013 in/in Tensile Strength (Yield) ASTM D638 7300 psi Tensile Strength (Break) ASTM D638 5300 psi Tensile Elongation (Yield) ASTM D638 6.0% Flexural Modulus ASTM D790 270500 psi Flexural Strength (Yield) ASTM D790 9950 psi Notched Izod Impact ASTM D256 -4°F (-20°C) 5 ft-lb/in 73°F (23°C) 11 ft-lb/in Unnotched Izod Impact ASTM D256 -4°F (-20°C) 29 ft-lb/in 73°F (23°C) 30 ft-lb/in Color & Aesthetics*** Green, medium blue, dark blue, red, orange, white, gray, black Color customization available based on specific needs KEY PROPERTIES Features: high-gloss finish, UV stability, scratch resistance, chemical/corrosion resistance, cold temperature impact resistance, heat resistance * Reflects average of several colors, properties shift slightly depending on color ** Gloss level varies based on tooling temperature *** UV data available upon request Copyright © 2023, Avient Corporation.
https://www.avient.com/sites/default/files/2020-10/edgetek-peek-product-selection-guide.pdf
EDGETEK™ POLYETHERETHERKETONE (PEEK) HIGH PERFORMING MELT-PROCESSABLE POLYMER PRODUCT SELECTION GUIDE Edgetek™ Polyetheretherketone (PEEK) HIGH PERFORMING MELT-PROCESSABLE POLYMER PROPERTY CONDITIONS TEST METHOD UNITS EDGETEK™ ET9800-0001 EM EDGETEK™ ET9800-0002 RS EDGETEK™ ET9800-0003 RS EDGETEK™ ET9800-0004 RS EC LUBRIONE™ LB9800-0001 AR PHYSICAL Mold Shrinkage - Transverse – ASTM D955 in/in 0.014 0.010 0.011 0.009 0.014 MECHANICAL Tensile Strength - Yield – ASTM D638 PSI 14425 15640 23680 36500 19700 Tensile Elongation - Yield – ASTM D638 % 5.4 3.0 2.2 1.5 0.2 Tensile Elongation - Break – ASTM D638 % 19.5 3.1 2.2 1.5 1.9 Tensile Modulus – ASTM D638 PSI 555150 827700 1591300 5301000 2285600 Flexural Modulus – ASTM D790 PSI 529300 690700 1418300 3084300 1443400 Flexural Strength – ASTM D790 PSI 23500 27300 36000 52100 30300 IMPACT Izod, Notched – ASTM D256 ft-lbs/in 1.0 0.7 1.1 1.3 0.6 Izod, Unnotched – ASTM D256 ft-lbs/in N.B. 13.1 15.3 13.8 5.0 THERMAL Melting Point – – °C 343 343 343 343 343 Glass Transition (DSC) – – °C 143 143 143 143 143 Heat Deflection Temp 264 psi, Unannealed ASTM D648 °C 151 178 320 325 > 300 CLTE, Flow Direction 23°C to 140°C ASTM E831 cm/cm/°C 4.0E-05 5.5E-05 2.2E-05 7.0E-06 1.9E-05 CLTE, Flow Direction 140°C to 250°C ASTM E831 cm/cm/°C 9.7E-05 7.8E-05 2.3E-05 6.5E-06 2.2E-05 Polyetheretherketone (PEEK) is widely considered to be one of the highest performing melt-processable polymers in the industry.
https://www.avient.com/sites/default/files/2023-10/LubriOne Product Selection Guide.pdf
LUBRIONE™ INTERNALLY LUBRICATED FORMULATIONS PRODUCT SELECTION GUIDE PRODUCT DESCRIPTION UNITS TEST METHOD NN–000/15T BLACK NN–20GF– 10GB/13T–2S BLACK NN–30GF/10T WHITE LB8900-0001 30GF/15T NATURAL LB8900-0002 30GF/13T-2S NATURAL LB8900-0003 18T-2S NATURAL ATT–000/5T BLACK AT–000/18T– 2S NATURAL 5209 FPL 20 NATURAL PS–30GF/2S NATURAL LB5210–0237 1B NATURAL PC–10CF/15T BLACK Base Polymer PA 66 PA 66 PA 66 PK PK PK POM POM POM PBT PP PC General Properties Specific Gravity g/cm3 ASTM D792 1.23 1.46 1.47 1.56 1.55 1.33 1.38 1.47 1.51 1.54 1.13 1.31 Molding Shrinkage ASTM D955 Flow % 1.0–2.0 0.20–0.50 0.50–1.0 0.30–0.60 0.20–0.40 1.7–2.3 1.5–2.0 2.0–3.0 2.0–3.0 0.20–0.40 0.10–0.30 0.10–0.30 Water Absoprtion (23°C, 24 hr.) % ASTM D570 0.8 – 0.050–1.0 0.3 0.4 0.4 0.050 – 0.050 – – – Mechanical Properties Tensile Modulus(1) MPa ASTM D638 2650 9650 9790 8050 7380 1250 965 1770 2420 8620 4140 – Tensile Strength(1) (Yield) MPa ASTM D638 61.4 119 122 119 94 47 35 40 45 108 72.4 90 Tensile Elongation(1) (Break) % ASTM D638 3.0–5.0 1.0–3.0 1.5 3 2 35 40 30 26 3 – – Flexural Modulus MPa ASTM D790 2760 6890 6890 7380 6410 1300 1080 1740 1790 6690 4840 5500 Flexural Strength MPa ASTM D790 108 172 214 182 167 55 41.4 62.7 68.3 165 110 130 Coefficient of Friction ASTM D1894 vs.
Steel - Dynamic ASTM D1894 – 0.212 0.186 – – – – – – – – – – – – CoF vs.
Steel - Static ASTM D1894 – 0.237 0.183 – – – – – – – – – – – – CoF (20min 0.2 m/s) g/min ASTM G77 – – – – – – – – – – – 0.79 0.79 – – Wear Rate (20h, 1m/s) g/min ASTM G77 – – – – – – – – – – – 1.02E-05 1.89E-05 – – Wear Rate (PV=2500) (in3-min/ ft-lb-hr) *10-10 ASTM D3702 – 125 175 – – – – – – – – – – – – Flammability Flame Rating UL 94 – – – – – – – HB HB V2 @ 3mm – – – – – LubriOne™ Internally Lubricated Formulations - PTFE-Free NOTES *ASTM D3702 (PV=2500, against 1018-steel) 1UHMWPE - ultra high molecular weight polyethylene 2MoS2 - molybdenum disulphide To learn more about LubriOne™ internally lubricated solutions, contact Avient at +1.844.4AVIENT (1.844.428.4368) www.avient.com EXPLORE WEAR RESISTANCE LubriOne internally lubricated thermoplastic polymers have been specifically designed to improve tribological performance in components, offering low coefficient of friction and improved wear–resistance properties.
https://www.avient.com/sites/default/files/2025-07/ISO IEC 17025 Chemical Avon Lake.pdf
No. 0514.02) 12/11/2023 Page 1 of 1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 AVIENT CORPORATION – ANALYTICAL SOLUTIONS 33587 Walker Road Avon Lake, OH 44012 Stephanie Mims Phone: 440-930-3499 CHEMICAL Valid To: September 30, 2025 Certificate Number: 0514.02 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following rubber and plastics tests: Test Description: Test Method or Standard: FTIR (Fourier Transform Infrared) Spectroscopy ASTM E1252 (Except 7.6, 11.2, and 11.4) Flammability Horizontal Burn of Self-Supporting Plastics ASTM D635; UL 94; IEC 60695-11-10 Horizontal Burn of Materials Used in Occupant Compartments of Motor Vehicles ASTM D5132; FMVSS 302 (49 CFR 571.302); ISO 3785 Vertical Burn, 20 mm ASTM D3801; UL 94; IEC 60695-11-10 Vertical Burn, 125 mm ASTM D5048; UL 94; IEC 60695-11-20 Thin Material Burning Test UL-94 Glow Wire Test IEC 60695 2-10, 2-11, 2-12, 2-13 Thermal Analysis DSC (Differential Scanning Calorimetry) ASTM D3418, E794, E1356 TGA (Thermogravimetric Analysis) ASTM E1131 TMA (Linear Thermal Expansion of Solid Materials by Thermomechanical Analysis) ASTM E831; ISO 11359-2 Karl Fischer Moisture Content ASTM D6869 For the tests to which this accreditation applies, please refer to the laboratory’s Chemical Scope of Accreditation.
https://www.avient.com/sites/default/files/resources/0514_02%2520PDI%2520ISO17025%2520Chemical_Extension%2520Cert2019.pdf
No. 0514.02) Revised 10/08/2019 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 POLYMER DIAGNOSTICS INC. 33587 Walker Road Avon Lake, OH 44012 Ana De La Ree Phone: 440-930-3271 CHEMICAL Valid To: December 31, 2019 Certificate Number: 0514.02 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following rubber and plastics tests: Test Description: Test Method or Standard: Analysis of Volatile Contaminants from Polymers (Chromatography) VDA 277 FTIR (Fourier Transform Infrared) Spectroscopy ASTM E1252 (Except 7.6, 11.2, and 11.4) Flammability Horizontal Burn of Self-Supporting Plastics ASTM D635; UL 94; IEC 60695-11-10 Horizontal Burn of Materials Used in Occupant Compartments of Motor Vehicles ASTM D5132; FMVSS 302 (49 CFR 571.302) Vertical Burn, 20 mm ASTM D3801; UL 94; IEC 60695-11-10 Vertical Burn, 125 mm ASTM D5048; UL 94; IEC 60695-11-20 Oxygen Index ASTM D2863 FT1 Flame Test UL1581, Clause 1060; UL2556/CSA C22.2 No 2556, Clause 9.3 Cable Flame Test UL1581, Clause 1061 VW1 Flame Test UL1581, Clause 1080; UL2556/CSA C22.2 No 2556, Clause 9.4 FT2/FH Flame Test UL1581, Clause 1100; UL2556/CSA C22.2 No 2556, Clause 9.1 FV-1 Flame Test UL1581, Clause 1060; UL2556/CSA C22.2 No 2556, Clause 9.5 Thin Material Burning Test UL-94 Glow Wire Test IEC 60695 2-10, 2-11, 2-12, 2-13 RVCM in PVC ASTM D4443 (A2LA Cert.
No. 0514.02) Revised 10/08/2019 Page 2 of 2 Test Description: Test Method or Standard: Thermal Analysis DSC (Differential Scanning Calorimetry) ASTM D3418, E794, E1356 TGA (Thermogravimetric Analysis) ASTM E1131 Karl Fischer Moisture Content ASTM D6869 Phthalate Determination by CPSIA CPSC-CH-C1001-09.3 1 The Consumer Product Safety Improvement Act (CPSIA) requires that every children's product subject to a federal consumer product safety requirement be tested by a Consumer Product Safety Commission (CPSC) accepted laboratory for compliance with the applicable federal children's product safety requirements.
https://www.avient.com/sites/default/files/2021-11/0514-02-dec2021.pdf
No. 0514.02) Revised 09/21/2021 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 POLYMER DIAGNOSTICS INC. 33587 Walker Road Avon Lake, OH 44012 Ana De La Ree Phone: 440-930-3271 CHEMICAL Valid To: December 31, 2021 Certificate Number: 0514.02 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following rubber and plastics tests: Test Description: Test Method or Standard: Analysis of Volatile Contaminants from Polymers (Chromatography) VDA 277 FTIR (Fourier Transform Infrared) Spectroscopy ASTM E1252 (Except 7.6, 11.2, and 11.4) Flammability Horizontal Burn of Self-Supporting Plastics ASTM D635; UL 94; IEC 60695-11-10 Horizontal Burn of Materials Used in Occupant Compartments of Motor Vehicles ASTM D5132; FMVSS 302 (49 CFR 571.302); ISO 3785 Vertical Burn, 20 mm ASTM D3801; UL 94; IEC 60695-11-10 Vertical Burn, 125 mm ASTM D5048; UL 94; IEC 60695-11-20 Oxygen Index ASTM D2863 FT1 Flame Test UL1581, Clause 1060; UL2556/CSA C22.2 No 2556, Clause 9.3 Cable Flame Test UL1581, Clause 1061 VW1 Flame Test UL1581, Clause 1080; UL2556/CSA C22.2 No 2556, Clause 9.4 FT2/FH Flame Test UL1581, Clause 1100; UL2556/CSA C22.2 No 2556, Clause 9.1 FV-1 Flame Test UL1581, Clause 1060; UL2556/CSA C22.2 No 2556, Clause 9.5 Thin Material Burning Test UL-94 Glow Wire Test IEC 60695 2-10, 2-11, 2-12, 2-13 RVCM in PVC ASTM D4443 (A2LA Cert.
No. 0514.02) Revised 09/21/2021 Page 2 of 2 Test Description: Test Method or Standard: Thermal Analysis DSC (Differential Scanning Calorimetry) ASTM D3418, E794, E1356 TGA (Thermogravimetric Analysis) ASTM E1131 Karl Fischer Moisture Content ASTM D6869 Phthalate Determination by CPSIA CPSC-CH-C1001-09.3, CPSC-CH-C1001-09.4 1 The Consumer Product Safety Improvement Act (CPSIA) requires that every children's product subject to a federal consumer product safety requirement be tested by a Consumer Product Safety Commission (CPSC) accepted laboratory for compliance with the applicable federal children's product safety requirements.
https://www.avient.com/sites/default/files/2023-03/Syncure XLPE Product Bulletin.pdf
This literature shall NOT operate as permission, recommendation, or inducement to practice any patented invention without permission of the patent owner. 1.844.4AVIENT www.avient.com TEST STANDARD UNIT SYNCURE™ XLPE S1054A ROHS NATURAL Specific Gravity ASTM D1505 – 0.919 Melt Flow Index, 190°C/2.16kg ASTM D1238 g/10min 1.045 Tensile Strength at Break ASTM D638 psi 2500 Tensile Elongation at Break ASTM D638 % 450 Delta Torque Internal g-m 2154 Moisture Content ASTM D2974 % 0.0004 Gel Content ASTM D2765 % 73 Hot Creep Elongation UL 2556 % 49 Hot Deformation UL 2556 % 6 TECHNICAL PROPERTIES *Gel Content, Hot Creep Elongation and Hot Deformation measured on 95 phr S1054A / 5 phr S100B system, and cured by autoclave for 9 hours
https://www.avient.com/sites/default/files/2024-12/Avient Norwalk A2LA ISO17025-17.pdf
No. 0962.01) 09/05/2023 Page 1 of 1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 AVIENT CORPORATION 80 North West Street Norwalk, OH 44857 Craig Polta Phone: 419 660 4278 MECHANICAL Valid To: September 30, 2025 Certificate Number: 0962.01 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following tests on plastics: Test Method(s) Test Name ASTM D256; ISO 180 Notched Izod ISO 179 (1eA) Determination of Charpy Impact ASTM D523 Gloss ASTM D618 (Method A) Conditioning of Test Specimens ASTM D792 (Method A) Specific Gravity ASTM D1238 (Method B) Melt Flow Rate ASTM D3012 Thermal Oxidative Stability ASTM D3641 Injection Molding Test Specimens FMVSS 302 Flammability ASTM E1331; SAE J1545 Spectrophotometric Color Difference SAE J1885 (Rev.
https://www.avient.com/sites/default/files/2022-03/Trilliant HC Electrically Conductive Formulations for Pipette Tips Application Bulletin.pdf
KEY PERFORMANCE PROPERTIES1 PHYSICAL NOMINAL VALUE UNIT TEST METHOD Density/Specific Gravity 1.00 ASTM D792 Melt Mass-Flow Rate (MFR) (230°C/2.16kg) 20 g/10 min ASTM D1238 MECHANICAL Tensile Strength 15.0 MPa ASTM D638 Flexural Modulus 1400 MPa ASTM D790 Flexural Strength 35.0 MPa ASTM D790 IMPACT Notched Izod Impact (Injection Molded) 150 J/m ASTM D256 ELECTRICAL Surface Resistivity < 100000 ohms/sq ASTM D257 PROCESSING INFORMATION INJECTION NOMINAL VALUE UNIT Drying Temperature 80 to 90 °C Drying Time 4.0 to 6.0 hr Processing (Melt) Temperature 220 to 250 °C Mold Temperature 30 to 80 °C Trilliant™ HC Electrically Conductive Formulations for Precision Performance Pipette Tips A critical design consideration for pipette tips is the accurate measurement of finite amounts of liquid.
https://www.avient.com/sites/default/files/2020-10/composites-innovation-cell-program-bulletin_0.pdf
Avient Advanced Composites – Polystrand 8375 Highfield Parkway Englewood, CO 80112 303.515.7700 TESTING SERVICES In-house testing capabilities allow for rapid material characterization and mechanical analysis according to the following standards: • ASTM D790 3-Point Flex • ASTM D7264 4-Point Flex • ASTM D2344 Short Beam Shear • ASTM C393 Core Compression • ASTM D7078 V-Notch Shear • ASTM D7249 4-Point Flex (Long Beam) • ASTM D6641 CLC Compression For more specialized resin and material analysis, additional testing capabilities are available through Polymer Diagnostics, Inc.