https://www.avient.com/sites/default/files/2023-11/reSound BIO TPEs Technical Bulletin.pdf
TECHNICAL BULLETIN
reSound™ BIO Thermoplastic Elastomers
Customizable Bio-based TPEs
reSound™ BIO TPEs are formulated utilizing between
35 and 60 percent bio-renewable content.
https://www.avient.com/sites/default/files/2021-06/colormatrix-select-brochure.pdf
COLORMATRIX SELECT WILL ENABLE:
• Immediate visibility of color
performance and cost data
for multiple formulation options
• On-demand color supply
• Full color choice with no minimum
order quantities
• Shorter development lead times
enabling faster market access and
multiple product introductions
• Assured global color consistency
• All the performance and process
efficiency advantages of ColorMatrix advanced
liquid colorants
MANUFACTURERS
TAKE CONTROL OF YOUR
COLOR SUPPLY
For manufacturers who use ColorMatrix Select will
be able to create and order color formulations online
in minutes.
Technical Support Services
Our team of technical service engineers are located
globally to provide full training and manufacturing
support.
Full on-site
technical support
Process
reporting
Regulatory
advice and
documentation
Custom dosing
systems
Rapid color
development
Colorant
and additive
technologies
COLOR IS GLOBAL
At Avient we think a lot about plastics: how to make them process better, perform better, look better and
be kinder to the planet.
https://www.avient.com/sites/default/files/2023-03/AvientRY 2021 CDP Verification Opinion Declaration_07-26-22r%5B96%5D.pdf
Data and information supporting the Scope 3 GHG emissions assertion were in many cases estimated rather
than historical in nature.
Level of Assurance and Qualifications:
Limited
This verification used a materiality threshold of ±5% for aggregate errors in sampled data for each of the
above indicators
GHG Verification Methodology:
Evidence-gathering procedures included, but were not limited to:
Interviews with relevant personnel of Avient and their consultant;
Review of documentary evidence produced by Avient;
Review of Avient data and information systems and methodology for collection, aggregation, analysis and
review of information used to determine GHG emissions; and
Audit of sample of data used by Avient to determine GHG emissions.
Attestation:
Scott Johnston, Lead Verifier David Reilly, Technical Reviewer
Principal Consultant Principal Consultant
Apex Companies, LLC.
https://www.avient.com/sites/default/files/2023-07/Avient_RY 2022 CDP Verification Opinion Declaration_07-24-23%5B30%5D.pdf
Data and information supporting the Scope 3 GHG emissions assertion were in many cases estimated rather
than historical in nature.
Level of Assurance and Qualifications:
Limited
This verification used a materiality threshold of ±5% for aggregate errors in sampled data for each of the
above indicators
GHG Verification Methodology:
Evidence-gathering procedures included, but were not limited to:
Interviews with relevant personnel of Avient and their consultant;
Review of documentary evidence produced by Avient;
Review of Avient data and information systems and methodology for collection, aggregation, analysis and
review of information used to determine GHG emissions; and
Audit of sample of data used by Avient to determine GHG emissions.
Attestation:
Scott Johnston, Lead Verifier Cody Lorentson, Technical Reviewer
Principal Consultant Program Manager
Apex Companies, LLC.
https://www.avient.com/sites/default/files/2024-09/Chemical Resistance Technical Bulletin %281%29.pdf
TECHNICAL BULLETIN
SOLUTIONS DESIGNED TO ADDRESS EVOLVING NEEDS
Determining the appropriate polymer for the job can prevent product failures, thereby reducing service calls,
product returns and warranty claims for manufacturers.
https://www.avient.com/sites/default/files/2021-06/edgetek-et8900-cr-technical-bulletin.pdf
TECHNICAL BULLETIN
1.844.4AVIENT
www.avient.com
Copyright © 2021, Avient Corporation.
https://www.avient.com/sites/default/files/2020-09/sem-stain-resistant-technical-bulletin.pdf
Based on visual test results
TECHNICAL BULLETIN
TEST METHOD: INDIGO STAIN RESISTANCE TEST
The same rigorous method used to test for staining on automotive interior seats, Ford Laboratory Test
Method – BN 107-01, was used.
https://www.avient.com/sites/default/files/2021-02/versaflex-non-blooming-solution-technical-bulletin.pdf
TECHNICAL BULLETIN
1.844.4AVIENT
www.avient.com
PROPERTY TEST METHOD UNITS VERSAFLEX
™
CE 3130-80N
VERSAFLEX™
CE 3130-70N
Shore Hardness ASTM D2240 Shore A 79 69
Specific Gravity ASTM D792 g/cm3 1.08 1.04
Tensile Strength ASTM D412 psi 2,484 2,222
Melting Flow Index (190°C, 21.6kg) ASTM D1238 g/10min 5.2 4.4
Elongation ASTM D412 % 864 667
Flexural Modulus @ 300% ASTM D790 psi 975 855
Viscosity @ 11,170 sec, 200°C ASTM D3835 Pa.s 30.6 22.2
Abrasion (Mass Lost) ASTM D3389 mg 1.1 2.6
UV Resistance 0.68W/m
2
45°C 168hours — Good Good
Stain Resistance *Condition 1*Condition 2 — Excellent Excellent
Blooming 85% RH30°C,168 hours — Non Non
Processing (Demold) — — Excellent Good
Cycle Time — — Short Middle
Overmold Substrate — — PC/ABS PC/ABS
KEY PROPERTIES AND OVERMOLD PERFORMANCE
Copyright © 2021, Avient Corporation.
https://www.avient.com/sites/default/files/2024-09/Colorant Chromatics Brochure_2024.pdf
10 standard colors
• All colors are heavy metal-free
• Special color matches can be done upon request
using Pantone® or RAL
color standards
• Customized pigment loadings can be provided to
address specialized coloration needs
• Functional additives can be provided
to address tailored properties
Let-down ratios and specific processing suggestions
are provided in the product data sheet available from
your Avient representative.
OUR CUSTOMER SUPPORT ACTIVITIES INCLUDE:
• Food and Drug Administration (FDA) compliance support
• Compliance with National Inventories
• Biocompatibility compliance
• REACH – European Legislation on Registration, Evaluation,
Authorization and Restriction of Chemicals
• Restriction on Hazardous Substances (RoHS) and Waste Electrical
and Electronic Equipment (WEEE) electronics compliance
• Data entry into the International Material Database System (IMDS)
• Hazardous communication, including safety data sheets (SDS)
and labeling
GENERATING REGULATORY COMPLIANCE
DOCUMENTATION INCLUDING:
• California Proposition 65
• European Food Contact
• Individual Customer Restricted Substance lists
• Drug Master Files
• Medical Application Files
• Food and Drug Administration Certification
• Potable Water Certification
Contact us if you have questions or for specific information
on your application’s regulatory compliance requirements.
https://www.avient.com/sites/default/files/resources/PolyOne%2520Standard%2520Quality%2520Response_2016_6_9.pdf
Specifications are generally agreed to before
purchase by each business’s technical
management.
What level of lab / technical support is
provided during the early phase of sales to a
new customer?
All critical systems located central data center.