https://www.avient.com/sites/default/files/resources/TRA%2520-%25202016%2520Annual%2520Report%2520for%252017%2520Tideman.pdf
The amounts and values for the
facility(ies) identified below are accurate, based on reasonable estimates using available data.
The data for the facility(ies) that I represent are
hereby submitted to the programs identified below using the Single Window Reporting Application.
I also acknowledge that the data will be made public.
https://www.avient.com/sites/default/files/2021-06/fl.datasheet-strengthmembers.pdf
K58220T N/A Kevlar®
2480 LBs
(1125 KGs)
230 FT/LB
(154 M/KG)
Flat 2.81 mm N/A
Strength member in
cable application
Product ID
Polymer Jacket
Base Fiber
Break
Yield Geometry
Nominal
Diameter
Description
13.75mm
K/Hytrel
Hytrel Jacket Kevlar®
29000 LBs
(13154 KGs)
138 KGs/KM Round 13.75mm
Kevlar rope w/ Hytrel
12.5mm K/TPU TPU jacket Kevlar®
24000 LBs
(10885 KGs)
115 KGs/KM Round 12.5mm
Kevlar rope w/ Hytrel
7.87mm
K/MDPE
MDPE Jacket Kevlar®
24000 LBs
(10885 KGs)
50 KGs/KM Round 7.87mm
Kevlar w/ MDPE
.58mm C/PU TPU jacket Carbon
74 LBs
(33.6 KGs)
N/A Round/ Flat .58mm
Carbon w/ TPU
4.50mm
K/HDPE
HDPE jacket Kevlar®
2000 LBs
(907 KGs)
16 KGs/KM Round 4.06 mm
Kevlar w/ HDPE
POPULAR JACKETED STRENGTH MEMBERS
This data is provided for informational purposes only, and does not constitute a specification.
Uranusweg 3
8938 AJ Leeuwarden
The Netherlands
+31(0) 58 216 75 99
info@fiber-line.com
ABOUT FIBER-LINE®
NOTICE: The information and data contained herein do not constitute sales specifications.
https://www.avient.com/sites/default/files/2024-12/PKE grades for Powersports Application Bulletin.pdf
Gasoline - 30% glass-filled (GF) grade, dry as molded (DAM), room temperature
Testing methodology is an adaptation from ASTM D543
• Reapply freshly soaked gauze pad every 24 hours to prevent from drying out
• Repeat for a total of 72 hours
• Tensile properties recorded
*Chemical resistance data for DEET, motor oil, glass cleaner, and sunscreen available upon request
KEY CHARACTERISTICS
Figure 1
Figure 2
3.34
3.84
3.63
1.96
2.21
0.99
3.43
3.86 3.93
1.76
3.49
2.01
3.26
3.66 3.74
1.45
1.06 0.989
2.98
3.99
3.41
1.41
1.07
0.88
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
30% LGF PKE 30% LGF PA6 30% LGF PA66 30% SGF PKE 30% SGF PA6 30% SGF PA66
Ft
-lb
/in
Notched Izod Impact
ASTM D256
23C DAM 23C Conditioned -40C DAM -40C Conditioned
1.47
1.37 1.37
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
Glass-Filled PKE Glass-Filled PA6 Glass-Filled PA66
g/
cm
3
Density of Polyketone vs Nylon
ASTM D792
LESS MOISTURE ABSORPTION THAN NYLON
30% Short Glass Fiber (SGF) Comparison
Moisture uptake, environmental chamber 62% RH, 70°C
SIMILAR DENSITY TO NYLON
ASTM D792
COMPARABLE AND CONSISTENT IMPACT PERFORMANCE*
Notched Izod Impact (ASTM D256) of LGF and SGF for DAM and
Conditioned Materials
*3,000 hr weathering data available upon request
KEY CHARACTERISTICS
1.844.4AVIENT
www.avient.com
Copyright © 2024, Avient Corporation.
https://www.avient.com/resources/safety-data-sheets?page=779
Avient has transitioned our Material Safety Data Sheets (MSDSs) to Safety Data Sheets (SDSs) for our manufactured products to meet the requirements of the Globally Harmonized System of Classification and Labeling of Chemicals (GHS), and CLP classification in Europe.
Technical Data Sheets
Safety Data Sheets
https://www.avient.com/resources/safety-data-sheets?page=4682
Avient has transitioned our Material Safety Data Sheets (MSDSs) to Safety Data Sheets (SDSs) for our manufactured products to meet the requirements of the Globally Harmonized System of Classification and Labeling of Chemicals (GHS), and CLP classification in Europe.
Technical Data Sheets
Safety Data Sheets
https://www.avient.com/resources/safety-data-sheets?page=4681
Avient has transitioned our Material Safety Data Sheets (MSDSs) to Safety Data Sheets (SDSs) for our manufactured products to meet the requirements of the Globally Harmonized System of Classification and Labeling of Chemicals (GHS), and CLP classification in Europe.
Technical Data Sheets
Safety Data Sheets
https://www.avient.com/sites/default/files/2022-10/Cesa WithStand Patient Mobility Case Study %281%29.pdf
Avient has compiled extensive data
that enabled the OEM to shave weeks off the product
development timeline and save nearly $50,000 in
potential antimicrobial product protection testing fees.
https://www.avient.com/sites/default/files/2021-06/fl.datasheet-twisting.pdf
Uranusweg 3
8938 AJ Leeuwarden
The Netherlands
+31(0) 58 216 75 99
info@fiber-line.com
ABOUT FIBER-LINE®
NOTICE: The information and data contained herein do not constitute sales specifications.
https://www.avient.com/resources/safety-data-sheets?page=1371
Avient has transitioned our Material Safety Data Sheets (MSDSs) to Safety Data Sheets (SDSs) for our manufactured products to meet the requirements of the Globally Harmonized System of Classification and Labeling of Chemicals (GHS), and CLP classification in Europe.
Technical Data Sheets
Safety Data Sheets
https://www.avient.com/resources/safety-data-sheets?page=784
Avient has transitioned our Material Safety Data Sheets (MSDSs) to Safety Data Sheets (SDSs) for our manufactured products to meet the requirements of the Globally Harmonized System of Classification and Labeling of Chemicals (GHS), and CLP classification in Europe.
Technical Data Sheets
Safety Data Sheets